APC Back-UPS BX550CI-AR Bedienungsanleitung
Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr APC Back-UPS BX550CI-AR (4 Seiten) in der Kategorie UPS. Dieser Bedienungsanleitung war fĂĽr 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/4
Installation and Operation
Back-UPS BX550CI-AR
Safety
Installation
Connect the Battery
Pull down on the battery connector handle, and then push it into the unit.
Connect Equipment
Connect equipment to the battery and surge protected outlets. These outlets
provide battery backup power and surge protection to all connected equipment.
Connect AC Power Cord
Connect the Back-UPS power cord directly into a wall outlet.
Turn on the Back-UPS
Press the Power ON button located on the front of the Back-UPS. The Power On LED will illuminate and a
single short beep will be audible to indicate that the Back-UPS is providing protection for connected
equipment.
The Back-UPS battery charges fully during the first 10 hours while connected to utility power. The Back-UPS
battery will charge while the Back-UPS is switched on or off and is connected to utility power. Do not expect
full battery run capability during the initial charge time.
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in contact with fluids, or where there is
excessive dust or humidity.
Be sure the air vents on the unit are not blocked. Allow adequate space for proper
ventilation.
Environmental factors impact battery life. High temperatures, poor quality A/C power,
and frequent, short duration discharges will shorten battery life.
Connect the Back-UPS directly to a wall outlet. Do not use surge protectors or
extension cords.
1ON/OFF button
2Battery connector
3Circuit breaker
4Input power cord
5Battery and surge protected outlets
bu195a
2
Transfer Voltage and Sensitivity Settings
Automatic Voltage Regulation boosts the utility voltage when it drops below safe levels. This allows the equipment
that is connected to the unit to operate during low voltage conditions. It will also regulate high voltage down to
safer levels.
The Back-UPS will switch to battery power if the input voltage level becomes too low for the Automatic Voltage
Regulation feature to compensate, or if the utility power is distorted.
If the Back-UPS switches to battery power too frequently or too infrequently, adjust the transfer voltage and
sensitivity settings:
1. Turn off the Back-UPS. Plug it into utility power.
2. Press and hold ON/OFF until the LED repeatedly flashes. The unit is now in Program Mode.
3. Release the button. The LED will flash once, twice, or three times per second, indicating the current
setting.
4. Press ON/OFF within two seconds to change the setting. Each time the button is pressed, the LED will
flash at a different rate: once, twice, or three times per second, indicating the new setting. Continue
pressing the button until the desired setting is reached. If the button is not pressed within five seconds, the
Back-UPS will exit the Program Mode.
Status Indicators
LED Flashing
Transfer
Voltage Setting
Input Voltage
Range Usage
Once per second Low 155 - 280 The Back-UPS will switch to battery power less often. Use
with equipment that is not sensitive to low or high level
voltage levels or minor voltage waveform distortions.
Twice per second Medium
(factory default)
160 -280 Default, use in normal conditions.
Three times per second High 165 - 270 The Back-UPS will switch to battery power during any
small fluctuation in voltage. Use with equipment that is
sensitive to low or high level voltage levels or minor voltage
waveform distortions.
LED Audible Alarm Condition
On Off Online - Back-UPS is supplying conditioned utility power to the connected
equipment
Constant Tone On Line Overload - The power drawn by the connected equipment exceeds the
power capacity of the unit
On (Off during
4 beeps)
4 beeps repeated
every 30 seconds
On-Battery - Back-UPS is supplying battery power
Flashing Rapid Beeping
(every 1/2 second)
Low Battery Warning - There are 2 minutes of run time remaining
Constant tone Bad Battery Detected - Battery needs to be charged, or is at end of life. (See
Battery Replacement.)
Chirp every 2
seconds
Charger Warning -Back-UPS has experienced an internal problem, but
continues to power the load. Contact APC Technical Support
Off Short beep every
4 seconds
Low Battery Shutdown - During On Battery operation the battery power was
almost completely exhausted, and the Back-UPS is waiting for utility power to
return to normal
Constant Tone On Battery Overload - Connected equipment requires more power than provided
by the Back-UPS battery. Unplug devices one at a time to remove overload, if not
corrected Contact APC Technical Support
Constant Tone Charger Fault - Back-UPS has an internal problem, and is no longer powering
the load. Contact APC Technical Support
3
Troubleshooting
Battery Replacement
The battery in the Back-UPS 550 is not user-replaceable. Contact APC Sales and Technical Support for a list of
authorized service centers near you.
Contact Information
Problem Probable Cause Solution
Back-UPS will not turn on. Circuit Breaker has tripped. Reduce the amount of equipment plugged into the
“Battery Backup + Surge Protection” outlets.
Reset the circuit breaker by pushing it back in.
Utility power is not available at the
wall outlet.
Ensure the fuse or circuit breaker for the wall
outlet is okay, and the wall switch controlling the
wall outlet (if any) is in the ON position.
Connected equipment loses
power.
The Back-UPS is overloaded. Ensure the equipment plugged into the outlets of
the unit are not overloading the capacity of the
unit. Try disconnecting some of the equipment
one device at a time, and see if the problem
continues.
The Back-UPS has exhausted its
available battery power.
The unit can only operate on battery power for a
limited amount of time. The unit will eventually
turn off when the available battery power has
been used. Allow the unit to recharge for 10 hours
before continuing to use the unit.
The equipment connected to the
Back-UPS does not accept the step-
approximated sine waveform from
the unit.
The output waveform is designed for computers
and computer-related equipment. It is not
designed for use with motor-type equipment.
The Back-UPS may require service. Contact APC Technical Support for further
troubleshooting.
The ON/OFF button is lit, and
the unit is beeping four times
every 30 seconds, or it is
emitting a constant tone.
The unit is using battery. The unit is operating normally and using battery
power. Save any current work, turn off all
equipment, and turn the unit OFF. Once normal
power is restored, turn the unit back ON, and turn
on all equipment.
The On/Off button flashes once
per second, and the Back-UPS
beeps once every ½ second.
Battery capacity is low (there are 2
minutes of run time remaining).
The unit is about to shut down due to a low
battery charge condition! When the unit beeps
once every ½ second, there are 2 minutes of run
time remaining. Immediately turn the computer
OFF and turn the UPS OFF. When power returns
to normal, the unit will recharge the battery.
Inadequate runtime. The battery is not fully charged. Allow the unit to charge by leaving it plugged in,
and switched on for 10 hours.
The battery is near the end of useful
life.
As a battery ages, the amount of runtime available
will decrease. Batteries also age prematurely if
the unit is placed near excessive heat. If the
battery will not charge, the Back-UPS is no
longer operable.
Worldwide 1 888 272 3858
Internet http://www.apc.com
Technical Support http://www.apc.com/support
Produktspezifikationen
Marke: | APC |
Kategorie: | UPS |
Modell: | Back-UPS BX550CI-AR |
Brauchst du Hilfe?
Wenn Sie Hilfe mit APC Back-UPS BX550CI-AR benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung UPS APC
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
5 Oktober 2024
3 Oktober 2024
Bedienungsanleitung UPS
- UPS Approx
- UPS Gembird
- UPS HP
- UPS Voltcraft
- UPS AEG
- UPS Siemens
- UPS IKEA
- UPS Dell
- UPS LC-Power
- UPS Tripp Lite
- UPS GYS
- UPS Adj
- UPS Block
- UPS Digitus
- UPS CyberPower
- UPS Eaton
- UPS EnerGenie
- UPS Emerson
- UPS Furman
- UPS Riello
- UPS Puls Dimension
- UPS Avocent
- UPS Atlantis Land
- UPS Vanson
- UPS Phoenix Contact
- UPS Minuteman
- UPS V7
- UPS Equip
- UPS Salicru
- UPS SurgeX
- UPS Bxterra
- UPS Altronix
- UPS FSP
- UPS Ditek
- UPS PowerWalker
- UPS FSP/Fortron
- UPS East
- UPS Liebert
- UPS Murr Elektronik
- UPS Online USV
Neueste Bedienungsanleitung fĂĽr -Kategorien-
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
4 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
3 Oktober 2024
2 Oktober 2024