Tripp Lite SmartOnline SU1500RTXLCD2U Bedienungsanleitung
Tripp Lite
UPS
SmartOnline SU1500RTXLCD2U
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Tripp Lite SmartOnline SU1500RTXLCD2U (92 Seiten) in der Kategorie UPS. Dieser Bedienungsanleitung war für 21 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/92
SU750RTXLCD2U
SU1000RTXLCD2U
SU1500RTXLCD2U
SU2200RTXLCD2U
SU3000RTXLCD3U
Quick
Start Guide—
Page 10
1
Owner’s Manual
SmartOnline™
Single-Phase Rackmount Online UPS Systems
with Built-in LCD Monitoring & Control Screen
Not suitable for mobile applications.
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright ©2013 Tripp Lite. All rights reserved. SmartOnline™ is a trademark of Tripp Lite. For latest updates, please visit www.tripplite.com
1. Overview 2
Parts List 2
Additional Accessory Options 2
Model Specific Accessories 2
2. Important Safety Instructions 3
3. Installation 4
Rack Mounting 4
Tower Mounting 6
4. Features 7
Front Panel Controls 7
Rear Panel Features 8
5. Basic Connection and Start-Up 10
Quick Start Guide 10
Optional Connections 11
6. Operation 13
Modes of Operation 13
LCD Informational Screens 16
UPS Setup Overview 18
Using PowerAlert 18
Using Front Panel LCD Interface 18
7. Troubleshooting 25
8. Internal Battery Replacement 26
9. Storage and Service 30
10. Warranty Registration 30
Español 31
Français 61
Warranty
Registration:
register online today for a
chance to win a FREE Tripp Lite
product—www.tripplite.com/warranty
NOTE: External battery pack options require configuration using front panel LCD interface or via Tripp Lite’s EXTERNAL BATTERY CONFIGURATION software.
See page 23 for more information if you are connecting external batteries to this UPS.
13-11-176-93-3156.indb 1 11/27/2013 4:24:32 PM
2
Overview
Tripp Lite SmartOnline Rackmount UPS Systems with interactive LCD interface feature online, double-conversion UPS protection with full-
time sine wave output and zero transfer time suitable for all advanced networking applications. Each system provides long running
battery support with optional extended-run and SNMP/Web communications ability. Built-in interfaces include USB, DB9 serial and
Emergency Power Off (EPO). The interactive front panel LCD screen provides detailed UPS status, preset and control options. An optional
economy mode setting reduces power consumption and BTU heat output.
Parts List
UPS System Bolt-on mounting ears (2) 4-post rail kit* PowerAlert CD
USB Cable EPO (RJ11) Cable RS-232 Cable Owner’s manual
*Note: 3kVA (3U) models will include a different 4-post rail kit than the one shown.
Additional Accessories (All Models; Optional)
•SNMPWEBCARD:InternalnetworkinterfacecardforSNMP/Webcontrolandmonitoring
•ENVIROSENSE:Temperature/HumiditysensorforusewithSNMPWEBCARD
•SRSWITCH:RackdoorsensorforusewithENVIROSENSEandSNMPWEBCARD
•RELAYIOCARD:ProgrammableRelayI/OCardforremoteUPSmonitoring
•2-9USTAND:SupportsrackmountUPSandbatterypacksinuprighttowerconfiguration(notforSU3000RTXLCD3U)
Model Specific Accessories (Optional)*
UPS Model SU750RTXLCD2U SU1000RTXLCD2U SU1500RTXLCD2U SU2200RTXLCD2U SU3000RTXLCD3U
External Battery Packs
(LIMIT 1)** BP24V15RT2U BP24V15RT2U BP48V24-2U BP48V24-2U BP72V15-2U
External Battery Packs
(NO LIMIT)** BP24V70RT3U BP24V70RT3U BP48V60RT3U BP48V60RT3U BP72V28RT3U
Hot-swap PDU System PDUB15 PDUB15 PDUB15 PDUB20 PDUB30
2 Post Rackmount Kit 2POSTRMKITWM 2POSTRMKITWM 2POSTRMKITWM 2POSTRMKITWM 2POSTRMKITHD
5 Year Extended
Warranty WEXT5-500-1500 WEXT5-500-1500 WEXT5-500-1500 WEXT5-2200-3000 WEXT5-2200-3000
*Visit the specification page for your UPS system at www.tripplite.com for detailed extended runtime data and additional accessory options.
** Note: External battery pack options require configuration using front panel LCD interface or via Tripp Lite’s EXTERNAL BATTERY CONFIGURATION software. See page 23 for
more information if you are connecting external batteries to this UPS.
13-11-176-93-3156.indb 2 11/27/2013 4:24:33 PM
3
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of all
Tripp Lite UPS Systems. Failure to heed these warnings may affect your warranty.
UPS Location Warnings
•InstallyourUPSindoors,awayfromexcessmoistureorheat,conductivecontaminants,dustordirectsunlight.
•Forbestperformance,keeptheindoortemperaturebetween32ºFand104ºF(0ºCand40ºC).
•LeaveadequatespacearoundallsidesoftheUPSforproperventilation.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the
unit’s internal cooling, eventually causing product damage not covered under warranty.
UPS Connection Warnings
•ConnectyourUPSdirectlytoaproperlygroundedACpoweroutlet.DonotplugtheUPSintoitself;thiswilldamagetheUPS.
•DonotmodifytheUPS'splug,anddonotuseanadapterthatwouldeliminatetheUPS’sgroundconnection.
•DonotuseextensioncordstoconnecttheUPStoanACoutlet.YourwarrantywillbevoidedifanythingotherthanTrippLitesurge
suppressors are used to connect your UPS to an outlet.
•IftheUPSreceivespowerfromamotor-poweredACgenerator,thegeneratormust
provide clean, filtered, computer-grade output.
•ThemainssocketoutletthatsuppliestheUPSshouldbeneartheUPSandbeeasilyaccessible.
•ToremoveACvoltagefromtheUPS,pulltheplugfromthesocketoutlet.
Equipment Connection Warnings
•Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcanreasonablybeexpectedtocausethefailureof
the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
•DonotconnectsurgesuppressorsorextensioncordstotheoutputofyourUPS.ThismightdamagetheUPSandmayaffectthesurge
suppressor and UPS warranties.
•ConnecttheUPStoanoutletthatisadequatelyprotectedagainstexcesscurrents,shortcircuitsandearthfaults,aspartofthe
building installation. The outlet protection for the UPS should be in series with the mains input.
Battery Warnings
• Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.Observeproperprecautions.Donotdisposeofthe
batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the
UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery
replacement should be performed only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid). The
batteries are recyclable. Refer to your local codes for disposal requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling
information. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.
tripplite.com/support/battery/index.cfm to locate the specific replacement battery for your UPS.
•Note:ExternalbatterypackoptionsrequireconfigurationusingfrontpanelLCDinterfaceorviaTrippLite’sEXTERNALBATTERY
CONFIGURATION software. See page 23 for more information if you are connecting external batteries to this UPS.
13-11-176-93-3156.indb 3 11/27/2013 4:24:33 PM
Produktspezifikationen
Marke: | Tripp Lite |
Kategorie: | UPS |
Modell: | SmartOnline SU1500RTXLCD2U |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Tripp Lite SmartOnline SU1500RTXLCD2U benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung UPS Tripp Lite
9 Oktober 2024
9 Oktober 2024
4 Oktober 2024
2 Oktober 2024
29 September 2024
19 September 2024
10 September 2024
8 September 2024
30 August 2024
16 August 2024
Bedienungsanleitung UPS
- UPS Approx
- UPS Gembird
- UPS HP
- UPS Voltcraft
- UPS AEG
- UPS Siemens
- UPS IKEA
- UPS Dell
- UPS LC-Power
- UPS GYS
- UPS Adj
- UPS Block
- UPS Digitus
- UPS APC
- UPS CyberPower
- UPS Eaton
- UPS EnerGenie
- UPS Emerson
- UPS Furman
- UPS Riello
- UPS Puls Dimension
- UPS Avocent
- UPS Atlantis Land
- UPS Vanson
- UPS Phoenix Contact
- UPS Minuteman
- UPS V7
- UPS Equip
- UPS Salicru
- UPS SurgeX
- UPS Bxterra
- UPS Altronix
- UPS FSP
- UPS Ditek
- UPS PowerWalker
- UPS FSP/Fortron
- UPS East
- UPS Liebert
- UPS Murr Elektronik
- UPS Online USV
Neueste Bedienungsanleitung für -Kategorien-
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
11 Oktober 2024
5 Oktober 2024