Owner’s Manual
230V Input, Line-Interactive
UPS Systems
(Tower Configuration)
Models: OMNIVSINT1000, OMNIVSINT1500XL
*
* Extended runtime options
Not suitable for mobile applications.
Important Safety Instructions 2
Quick Installation 3
Basic Operation 5
Storage & Service 8
Español 9
Français 17
РуссĐșĐžĐč 25
2
Important Safety Instructions
UPS Location Warnings
‱ Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.
‱ For best performance, keep the indoor temperature between between 32Âș F and 104Âș F
(0Âș C and 40Âș C).
‱ Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
‱ Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into
itself; this will damage the UPS.
‱ Do not modify the UPS plug, and do not use an adapter that would eliminate the UPS ground
connection.
‱ Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided
if anything other than Tripp Lite surge protectors are used to connect your UPS to an outlet.
‱ If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
Equipment Connection Warnings
‱ Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
‱ Do not connect surge protectors or extension cords to the output of your UPS.
Battery Warnings
‱ Batteries can present a risk of electrical shock and burn from high short-circuit current.
Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or
batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the
UPS before performing battery replacement. Use tools with insulated handles. There are no
user-serviceable parts inside the UPS. Battery replacement should be performed only by
authorized service personnel using the same number and type of batteries (Sealed Lead-
Acid). The batteries are recyclable. Refer to your local codes for disposal requirements.
Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).
Visit Tripp Lite on the Web at tripplite.com/support/battery/index.cfm to locate the specific
replacement battery for your UPS.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation,
operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void
your warranty.
3
Quick Installation
1 Unplug the computer’s power cord from
both AC outlet and the computer’s AC
input.
2 Insert the female plug of the computer’s
cord into the UPS AC input. A Insert the
male plug of the computer's cord into AC
outlet.
Note: After you plug the UPS into a live AC outlet, the
UPS will turn ON automatically. See “ON/OFF” Button
description in the Basic Operation section if you want to
place the UPS in any mode other than ON.
3 Using one of the jumper cords supplied
with the UPS, insert the cord’s female
plug into computer’s AC input B. Insert
the cord’s male plug into any of UPS’s
female output receptacles.
4 Plug additional equipment into the UPS.*
Use one of the additional jumper cords supplied
with the UPS, or order additional jumper cords
from Tripp Lite. Log on to tripplite.com/support;
order part # P004-006.
* Your UPS is designed to support only computer
equipment. You will overload the UPS if the total VA
ratings for all the equipment you connect exceeds the
UPS’s output capacity. To find your equipment's VA ratings,
look on their nameplates. If the equipment is listed in
amps, multiply the number of amps by 230 to determine
VA. (Example: 1 amp × 230 = 230 VA). If you are unsure
if you have overloaded the UPS’s outlets, see “OUTPUT
LOAD LEVEL” LED description.
1
2
IEC320-C14 plug shown
A
3
4
Shown: OMNIVSINT1000
B
Shown: OMNIVSINT1000
Shown: OMNIVSINT1000

Produktspezifikationen

Marke: Tripp Lite
Kategorie: niet gecategoriseerd
Modell: OMNIVSINT800

Brauchst du Hilfe?

Wenn Sie Hilfe mit Tripp Lite OMNIVSINT800 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung niet gecategoriseerd Tripp Lite

Bedienungsanleitung niet gecategoriseerd

Neueste Bedienungsanleitung fĂŒr -Kategorien-