Tripp Lite Internet900U Bedienungsanleitung

Tripp Lite UPS Internet900U

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Tripp Lite Internet900U (36 Seiten) in der Kategorie UPS. Dieser Bedienungsanleitung war für 9 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/36
1
UPS Systems
Models:
BC800U, INTERNET750U, INTERNET900U
(Series Numbers: AG-0314, AG-0317, AG-0390)
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2018 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
Español 13 • Français 24
18-11-059-93388E.indb 1 12/7/2018 5:46:25 PM
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation and storage of this product. Failure to heed these warnings
may affect the warranty.
UPS Location Warnings
Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust
or direct sunlight.
For best performance, keep the indoor temperature between 32º F and 104º F
(0º C and 40º C).
Leave adequate space around all sides of the UPS for proper ventilation.
Optional mounting: The UPS may be securely mounted in a horizontal or vertical position.
To mount, use two screws (not provided) to secure the UPS rear keyholes to a flat surface.
UPS Connection Warnings
Connect your UPS directly to a properly-grounded AC power outlet. Do not plug the UPS into
itself; this will damage the UPS.
Do not modify the UPS plug and do not use an adapter that would eliminate the UPS
ground connection.
Do not use extension cords to connect the UPS to an AC outlet.
If the UPS receives power from a motor-powered AC generator, the generator must provide
clean, filtered, computer-grade output.
The mains socket outlet that supplies the UPS should be easily accessible and located near
the UPS.
Equipment Connection Warnings
Install in accordance with National Electrical Code standards ANSI/NFPA
70 and Canadian Electrical Code, Part I, C22.1.
Short-circuit backup protection and overcurrent protection is provided by
the building installation.
To reduce the risk of fire, connect only to a circuit with a maximum 20A
provided branch circuit overcurrent protection in accordance with the
National Electrical Code, ANSI/NFPA 70 and the Canadian Electrical Code,
Part I, C22.1. The plug on the power supply cord is intended to serve as
the disconnect device. Be sure that the socket-outlet is installed near the
equipment and is made easily accessible.
The UPS is intended for use on a TN power distribution system.
Important Safety Instructions
18-11-059-93388E.indb 2 12/7/2018 5:46:25 PM
3
Important Safety Instructions
Main relay
Breaker
I/P Filter
DC-AC
Inverter
DC-DC
Converter
AC-DC
Charger
O/P relay
IP-L O/P-L
IP-N O/P-N
IP/G O/P-G
Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
Do not connect surge protectors or extension cords to the output of your UPS. This might
damage the UPS and may affect the surge protector and UPS warranties.
Connect the UPS to an outlet that is adequately protected against excess currents, short
circuits and earth faults as part of the building installation.
18-11-059-93388E.indb 3 12/7/2018 5:46:26 PM


Produktspezifikationen

Marke: Tripp Lite
Kategorie: UPS
Modell: Internet900U

Brauchst du Hilfe?

Wenn Sie Hilfe mit Tripp Lite Internet900U benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung UPS Tripp Lite

Bedienungsanleitung UPS

Neueste Bedienungsanleitung für -Kategorien-