Tripp Lite BC350 Bedienungsanleitung
Tripp Lite
UPS
BC350
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Tripp Lite BC350 (24 Seiten) in der Kategorie UPS. Dieser Bedienungsanleitung war für 39 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/24
1
Owner’s Manual
Internet Office® & BC Personal®
UPS Systems
Not suitable for mobile applications.
Important Safety Instructions 2
Quick Installation 3
Basic Operation 4
Storage & Service 7
Español 9
Warranty Registration 7
Français 16
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Copyright © 2010 Tripp Lite. All rights reserved.
Internet Office® and BC Personal
® are registered trademarks of Tripp Lite.
Register
online today
for a chance to win a
FREE Tripp Lite product!
www.tripplite.com/warranty
201004182 93-2292.indb 1 5/6/2010 11:30:36 AM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS—This manual contains instructions and warnings that
should be followed during the installation, operation and storage of all Tripp Lite UPS
Systems. Failure to heed these warnings may affect your warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants,
dust or direct sunlight.
• For best performance, keep the indoor temperature between 32º F and 104º F (0º C and
40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the
UPS into itself; this will damage the UPS.
• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s
ground connection.
• Do not use extension cords to connect the UPS to an AC outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must
provide clean, filtered, computer-grade output.
Equipment Connection Warnings
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
• Do not connect surge suppressors or extension cords to the output of your UPS. This
might damage the UPS and may affect the surge suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason.
There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high short-circuit current.
Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the
UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug
and turn off the UPS before performing battery replacement. Use tools with insulated
handles. There are no user-serviceable parts inside the UPS. Battery replacement should
be performed only by authorized service personnel using the same number and type of
batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for
disposal requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling
information. Tripp Lite offers a complete line of UPS System Replacement Battery
Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/support/battery/
index.cfm to locate the specific replacement battery for your UPS.
• Do not attempt to add external batteries to the UPS.
201004182 93-2292.indb 2 5/6/2010 11:30:36 AM
3
1 Plug the UPS into a properly grounded AC outlet.
After plugging the UPS into a wall outlet, push the ON/OFF/TEST button for one
second to turn the UPS on (see Basic Operation section). Please Note! will The UPS
not turn on automatically in the presence of live utility power.
2 Plug your equipment into the UPS.
Select outlets (see Basic Operation section) will provide battery backup and surge
protection; plug your computer, monitor and other critical devices here.* Select outlets
(see Basic Operation section) will provide surge protection only; plug your printer and
other non-essential devices here.
* Your UPS is designed to support electronic equipment only. You will overload the
UPS if the total VA ratings for all the equipment you connect to the Battery Backup
Protected/Surge Protected outlets exceeds the UPS’s output capacity. To find your
equipment’s VA ratings, look on their nameplates. If the equipment is listed in amps,
multiply the number of amps by 120 to determine VA. (Example: 1 amp × 120 = 120
VA). If you are unsure if you have overloaded the Battery Backup Protected/Surge
Protected outlets, run a self-test (see “ON/OFF/TEST” Button description).
If the LINE POWER indicator light does not illuminate when the UPS is turned ON,
try the following:
1. Make sure that the UPS is plugged into a live AC outlet.
2. If your UPS has a sliding ON/OFF switch, place it back in the OFF position, wait
several seconds, then place it in the ON position again.
3. If your UPS had an ON/OFF button, you must press it for at least one second to start
the UPS. (A beep should sound when the UPS starts.)
4. If the UPS still does not start, contact Tripp Lite Tech Support for assistance.
Quick Installation
201004182 93-2292.indb 3 5/6/2010 11:30:36 AM
Produktspezifikationen
Marke: | Tripp Lite |
Kategorie: | UPS |
Modell: | BC350 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Tripp Lite BC350 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung UPS Tripp Lite
9 Oktober 2024
9 Oktober 2024
4 Oktober 2024
2 Oktober 2024
29 September 2024
19 September 2024
10 September 2024
8 September 2024
30 August 2024
16 August 2024
Bedienungsanleitung UPS
- UPS Approx
- UPS Gembird
- UPS HP
- UPS Voltcraft
- UPS AEG
- UPS Siemens
- UPS IKEA
- UPS Dell
- UPS LC-Power
- UPS GYS
- UPS Adj
- UPS Block
- UPS Digitus
- UPS APC
- UPS CyberPower
- UPS Eaton
- UPS EnerGenie
- UPS Emerson
- UPS Furman
- UPS Riello
- UPS Puls Dimension
- UPS Avocent
- UPS Atlantis Land
- UPS Vanson
- UPS Phoenix Contact
- UPS Minuteman
- UPS V7
- UPS Equip
- UPS Salicru
- UPS SurgeX
- UPS Bxterra
- UPS Altronix
- UPS FSP
- UPS Ditek
- UPS PowerWalker
- UPS FSP/Fortron
- UPS East
- UPS Liebert
- UPS Murr Elektronik
- UPS Online USV
Neueste Bedienungsanleitung für -Kategorien-
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
11 Oktober 2024
5 Oktober 2024