Duct version with
display
Wall version with
display
Highly accurate testo humidity sensor with long-term
stability (±2.0% RH)
Optional 2-line LCD display
P2A software for parameterization, adjustment and analysis,
saves time and costs in commissioning and maintenance
Optimum calibration concept thanks to adjustment of the
entire signal chain (1-point, 2-point and analog adjustment)
Adjustment without dismantling the transmitter
2 analog outputs (humidity/temperature), option of 1
passive humidity and temperature analog output
Humidity transmitter
testo 6621
A broad variety of the testo 6621 transmitter is available.
Depending on the application in a room or in a duct,
the corresponding designs can be selected. A display
is available as an option. You can choose between
the housing colours grey and white. The testo 6621 is
persuasive in technical terms thanks to the patented
humidity sensors that guarantee the highest accuracy. The
sensors and the analog outputs can be adjusted, analyzed
and parameterized via the external interface using the P2A
software.
The testo 6621 is a high-performance transmitter for a low
price. It meets the increasing requirements in automated
building services in terms of accuracy, reliability and safety
and thereby saves energy costs.
www.testo.com
%RH
°C
testo 6621 – Humidity transmitter
Technical data
Power
Display
Humidity
testo 6621 –
A01/A03 (wall
version)
testo 6621
– A02 (duct
version)
testo 6621 –
A01/A03 (wall
version)
testo 6621
– A02 (duct
version)
Analog outputs
Housing
Other features
Display 2-line LCD (optional)
Operation
Parameterization P2A software
Assembly
Cable screw connection None (cable routed
through rear wall
opening or
break-out opening on
bottom)
1 x M16 x 1,5
Parameters
Meas. range 0 to 100% RH (>90% RH only briefly)
(not for high humidity processes)
Temperature
Meas. range 0 to +60 °C
(+32 to +140 °F)
-20 to +70 °C
(-4 to +158 °F)
Accuracy* ±2.0 %RH (0 to 90 %RH),
±4 %RH (90 to 100 %RH)
Accuracy ±0,5 °C / 0,9 °F
Sensor Active signal output: NTC
Passive signal output: NI1000
Output type 4 to 20 mA (2-wire)
0 to 1/5/10 V (4-wire)
Measuring rate 1/s
Accuracy of analog
outputs
4 to 20 mA ±0,05 mA
0 to 1 V ±2,5 mV
0 to 5 V ±12,5 mV
0 to 10 V ±25 mV
Temperature
dependency/coefficient
Temperature coefficient: 0.05%/K
(gap of 25 °C/77 °F)
Replaceability of sensor Through Testo
Service
Can be done
by customer (s.
below, Replacement
sensors), subsequent
2-point adjustment
required
Sensor Testo humidity sensor
Inputs and outputs
Number of channels 2 channels (humidity and temperature)
Voltage supply 20 to 30 V AC/DC
Current consumption
Output
2-wire current 4 to
20 mA
Voltage supply [V] Current consumption
[mA]
20 20
24 20
30 30
4-wire voltage 0 to 10V 24 7
30 7
20 20
24 22
30 28
General
Material / colour ABS/
pure white (RAL 9010) or light grey
Weight 160 g80 g / 90 g (A03)
Dimensions 81 x 81 x 26 mm 81 x 81 x 42 mm
see drawing for
probe
Resolution Humidity: 0.1 %RH
Temperature: 0.1 °C/°F
Electronics temperature
(housing) (with/without
display)
0 to +60 °C/32 to +140 °F (A01/A03),
With display: 0 to +50 °C/+32 to +122 °F;
-20 to +70 °C/-4 to +158 °F (A02),
With display: 0 to +50 °C/+32 to +122 °F
Storage temperature -40 to +70 °C (-40 to +176 °F)
Measuring medium Air in air-conditioning systems or air-
conditioned rooms
Protection class IP30 IP65
EMC According to EC directive 2004/108/EEC
Operating conditions
Interfaces 1x mini-DIN for connecting PC
Reaction time t90:
<
15 s at 2 m/s;
For calibration and adjustment, please note:
The response time may be considerably
higher in static air
Scaling range -50 to 100 °C / -58 to 212 °F,
0 to 100 %RH
* The determination of the measurement uncertainty takes place
according to GUM (Guide to the Expression of Uncertainty in
Measurement):
In the determination, the accuracy of the measuring instrument
(hysteresis, linearity, reproduceability), the uncertainty contribution of
the test site as well as the uncertainty of the adjustment site/works
calibration are taken into account. For this purpose, k=2 of the extension
factor, the usual value in measurement technology, is used as a basis,
corresponding to a trust level of 95%.
123456
+-+-+- UrHT
-+
1 2 3 4 5 6
+-
+-
+-
UrH T
~
24V~
6543
+- + -rH T
+
-
U
II
654321
+ -+ -+ - T rHU
+-U
U U
123456
+-+-+- UrHT
123456
+-+-+- UrHT
654321
+ -
+ -+ - TrHU
+-U U R
6 5 4 3
+- +- rH
T
+
-
U
testo 6621 – A01
(wall version)
testo 6621 – A02
(duct version)
testo 6621 – A03
(wall version)
testo 6621 – Humidity transmitter
Technical drawings / Connection plan
Technical drawings
Connection plan
A01 Wiring, 3-wire
A02 Wiring, 3-wire A02 Wiring, active/passive A02 Wiring, active/passive
A01 Wiring, active/passive A01 Wiring A02 Wiring
A03 Wiring
Produktspezifikationen
Marke: | Testo |
Kategorie: | Messung |
Modell: | 6621 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Testo 6621 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Messung Testo
23 Mai 2024
13 Mai 2024
16 April 2024
2 April 2024
30 März 2024
10 März 2024
3 März 2024
27 Februar 2024
21 Februar 2024
15 Februar 2024
Bedienungsanleitung Messung
- Messung Hama
- Messung REV
- Messung Voltcraft
- Messung Bosch
- Messung Laserliner
- Messung Velleman
- Messung Powerfix
- Messung Alecto
- Messung Beurer
- Messung Bresser
- Messung König
- Messung TFA
- Messung Black And Decker
- Messung Trotec
- Messung DeWalt
- Messung Pioneer
- Messung Megasat
- Messung Smartwares
- Messung Garmin
- Messung GOCLEVER
- Messung Perel
- Messung Workzone
- Messung Microlife
- Messung Rossmax
- Messung Amprobe
- Messung Meec Tools
- Messung Metrix
- Messung IHealth
- Messung Ansmann
- Messung Westfalia
- Messung Livington
- Messung Silverline
- Messung Yato
- Messung Be Cool
- Messung Toolland
- Messung AS Schwabe
- Messung Hager
- Messung Kyoritsu
- Messung Eurolite
- Messung GW Instek
- Messung KERN
- Messung Milwaukee
- Messung Eizo
- Messung Victron Energy
- Messung Peak
- Messung Kübler
- Messung Carrier
- Messung Lund
- Messung SHX
- Messung Gima
- Messung Testboy
- Messung Danfoss
- Messung Fantini Cosmi
- Messung Multimetrix
- Messung Extech
- Messung BENNING
- Messung Fluke
- Messung FLIR
- Messung Vemer
- Messung Oregon Scientific
- Messung Ridgid
- Messung Stabila
- Messung Hikmicro
- Messung Entes
- Messung Gossen Metrawatt
- Messung Hameg
- Messung Joy-it
- Messung Megger
- Messung Muller
- Messung PCE Instruments
- Messung RK Technology
- Messung Sanwa
- Messung Sonel
- Messung Uni-T
- Messung VirtuFit
- Messung Wachendorff
- Messung TFA Dostmann
- Messung Vimar
- Messung Owon
- Messung PeakTech
- Messung Comark
- Messung Dahua Technology
- Messung YSI
- Messung Aluratek
- Messung SRS
- Messung Eltako
- Messung H-Tronic
- Messung HT Instruments
- Messung Beha-Amprobe
- Messung Chauvin Arnoux
- Messung Werma
- Messung Eastron
- Messung Emko
- Messung Pancontrol
- Messung X-Rite
- Messung CESYS
- Messung Trumeter
- Messung Kemo
- Messung ORNO
- Messung Tempest
- Messung TDE Instruments
- Messung Zircon
- Messung Kreg
- Messung Apollo Ultrasonic
- Messung BJZ
- Messung Adwa
- Messung Greisinger
- Messung Qubino
- Messung Beckmann & Egle
- Messung Weidmüller
- Messung Janitza
- Messung CEM
- Messung Klein Tools
- Messung Daytronic
- Messung AREXX
- Messung Delta Ohm
- Messung Camille Bauer
- Messung Rigel Medical
- Messung UHoo
- Messung Seaward
- Messung AstroAI
- Messung P3 International
- Messung Seek Thermal
- Messung ClimeMET
- Messung Fixpoint
- Messung Condtrol
- Messung Cliff
- Messung Water-i.d.
- Messung Stahlwille
- Messung KS Tools
- Messung AkYtec
Neueste Bedienungsanleitung für -Kategorien-
4 August 2024
24 Juni 2024
24 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
22 Juni 2024
21 Juni 2024
21 Juni 2024