SPECIFICATION
Model no.
Advance 2.9MM
plus
Advance 3.5MM
plus
Cooling capacity
10000 BTU/hr
2520 Kcal/hr
2930 watts
12000 BTU/hr
2770 Kcal/hr
3516 watts
Power/Ampere consumption for cooling*
1180W/ 5.3A
1500W/ 6.7A
Air volume (max. speed) 420m
3
/h 500m
3
/h
Humidity removal capacity 1,8 L/h 2,0 L/h
Power supply 230V/50Hz/1phase
Compressor rotary
Refrigerant R410A
Refrigerant load* 525g 530g
Fan speed 3
Timer electronic switch 1 24 hours
Working temperature 18 ~ 32
o
C
Exhaust pipe Ø 142X1500mm
Net Weight 31 kgs 32 kgs
Dimension 450X365X825 mm (WxDxH)
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do
not play with the appliance.
2
BEFORE USE
GENERAL SAFETY
ONLY USE IN THE UPRIGHT POSITION
ON A FLAT LEVEL SURFACE AND AT
LEAST 36cm FROM ANY OBJECTS (Fig
1 & 4).
DO NOT PLACE OBJECTS ON THE
UNIT OR RESTRICT AIR INLET /
OUTLET (FIG. 2).
CLOSELY SUPERVISE ANY CHILDREN
AND PETS WHEN UNIT IS IN USE.
ELECTRICAL SAFETY
FOR INDOOR USE ONLY.
SWITCH OFF AND UNPLUG WHEN
NOT IN USE.
DO NOT USE IN HUMID OR WET
ENVIRONMENTS (FIG 3)
DO NOT PULL THE UNIT ALONG BY
THE CORD.
IF THE SUPPLY CORD IS DAMAGED,
IT MUST BE REPLACED BY AN
ELECTRICIAN OR SIMILARLY
QUALIFIED PERSON, TO AVOID
HAZARD.
FOR MAXIMUM EFFICENCY
Do not exceed the recommended room
size
Close doors and windows
Keep curtains of blinds closed during
the sunniest part of the day
Keep filters clean
Once room has reached the desired
conditions, reduce temperature and
ventilation settings
FIG. 1
FIG. 2
FIG.3
FIG.4
3


Produktspezifikationen

Marke: Suntec
Kategorie: Klimaanlage
Modell: Klimatronic Advance 2.9 plus

Brauchst du Hilfe?

Wenn Sie Hilfe mit Suntec Klimatronic Advance 2.9 plus benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Klimaanlage Suntec

Bedienungsanleitung Klimaanlage

Neueste Bedienungsanleitung für -Kategorien-