Summit SBC58BFRTPCF Bedienungsanleitung

Summit Tapsysteem SBC58BFRTPCF

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Summit SBC58BFRTPCF (24 Seiten) in der Kategorie Tapsysteem. Dieser Bedienungsanleitung war für 2 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/24
KEGERATOR WITH FRONT DISPENSING TAP (S)
Models:
SBC54OSFRTP
SBC56BGSSFRTP
SBC56GWFRTP
SBC58BSSFRTP
SBC58BLFRTP
SBC58WHFRTP
SBC56BGFRTP
SBC56GWHFRTP
SBC7BFRTP
ALBC7BFRTP
SBC7WFRTP
ALBC7WFRTP
SBC682FRTP
SBC683OSFRTP
BC3TFRTP
WBC3FFRTP
LBC24OSFRTP
BC74OSFRTP
WBC3ZOSFRTP
LBC243TFRTP
FFAR25L7FRTP
FF31L7FRTP
SBC58BFRTP
SBC58BFRTPADA
SBC7BRSFRTP
SBC7BRSFRTPADA
SBC58BFRTPCF
SBC58BFRTPCFADA
SBC7BRSFRTPCF
SBC7BRSFRTPCFADA
Instruction Manual
BEFORE USE, PLEASE READ AND FOLLOW SAFETY ALL RULES AND OPERATING INSTRUCTIONS
Felix Storch, Inc.
An ISO 9001:2015 registered
company
770 Garrison Ave Bronx,
New York 10474
www.summitappliance.com
Write Model and Serial Numbers here:
Model:
Serial No.
2
Table of Content
Important Safeguards 3 – 5
Location of Parts & Accessories 6
Installation Instructions 7 11–
Before Using Your Appliance 7
Installing Your Appliance 7
Electrical Connection 8
Extension Cord 8
Reversing the Door Swing 9
Door Handle Installation 9
Installing the Casters 10
Adjusting the Tilt 10
Leg Shield 10
Installing the Front Tap Kegerator 11
Beer Kegs and Keg Tappers 11 – 12
Assembling the CO2 Regulator and CO2 Tank 11
Installing the CO2 Tank 12
Installing the Beer Keg 12
Coffee and Wine Keg Tappers 13 – 15
Assembling the N
2 Canister 13
– Installing the Cold Brew Coffee Tap Kits 13 14
Installing Wine Keg Tap on Single Barrel Type Keg 15
Operating Your Appliance 16 20–
Temperature Control 16 17–
Mechanical Thermostat 16
– Digital Thermostat 16 17
Defrosting Your Appliance 17
Care and Maintenance 18
Cleaning Your Appliance 18
Power Failure 18
Vacations 18
Moving Your Appliance 18
Energy 18-Saving Tips
Troubleshooting 19 20 –
Limited Warranty 24
3
Your safety and the safety of others are very important.
Before the is used, it must be properly positioned and installed as unit
described in this manual, so read the manual carefully. To reduce the
risk of fire, electrical shock or injury when using the appliance, follow
basic precautions, including the following:
• Plug into a grounded 3- prong outlet. Do not remove grounding prong, do not use
an adapter, and do not use an extension cord.
• a , It is recommended that separate circuit, serving only your unit be provided. Use
receptacles that cannot be turned off by a switch or pull chain.
• Never clean appliance parts with flammable fluids. These fumes can create a fire
hazard or explosion. not store or use gasoline or other flammable vapors and And do
liquids in the vicinity of this or any other appliance. The fumes can create a fire hazard
or explosion.
• Before proceeding with cleaning and maintenance operations, make sure the power
line of the unit is disconnected.
• Do not connect or disconnect the electric plug when your hands are wet.
• Unplug the appliance or disconnect the power before cleaning or servicing. Failure
to do so can result in electrical shock or death.
• Do not attempt to repair or replace any part of your unit unless it is specifically
recommended in this material. All other servicing should be referred to a qualified
technician.
• - - This appliance is CFC and HFC free and contains small quantities of Isobutane
(R600a) which is environmentally but flammable. does not damage friendly, It the
ozone layer, nor does it increase the greenhouse effect. Care must be taken during
transportation and setting up of the appliance that no parts of the cooling system are
damaged. Leaking coolant can ignite and may damage the eyes.
In the event of any damage:
–
Avoid open flames and anything that creates a spark.
–
Disconnect from the . power source
–
Air the room in which is the appliance located for several minutes .
–
Contact the Service Department for advice.
• The more coolant there is in an appliance, the larger the room in which it should be
installed. In the event of a leakage, if the appliance is in a small room, there is the
danger of combustible gases building up. For every ounce of coolant, at least 325 cubic
feet of room space of coolant is required. The amount in the appliance is stated on the
data plate Authorized inside the appliance. It is hazardous for anyone other than an
Service Person to carry out servicing or repairs to this appliance.
• Take serious care when handling, moving, and using the appliance to avoid either
damaging the refrigerant tubing or increasing the risk of a leak.
• -Replacing component parts and servicing shall be done by factory authorized service
personnel as so to minimize the risk of possible ignition due to incorrect parts or
improper service.
IMPORTANT SAFEGUARDS

Produktspezifikationen

Marke: Summit
Kategorie: Tapsysteem
Modell: SBC58BFRTPCF

Brauchst du Hilfe?

Wenn Sie Hilfe mit Summit SBC58BFRTPCF benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten