Description:
This system contains a STI-6400 with a DPDT key switch
to be mounted on one side of a door or wall; and a
similar looking housing, also with a DPDT key switch,
but without an alarm for the opposite side of the door.
An authorized person with a key can disable the alarm
on either side of the door. When disabled, and LED will
illuminate, and the door can be opened without setting
off the alarm. After passing through the door, the
alarm can be armed again from the opposite side.
Installation:
1. Follow STI-6400 mounting instructions and set
switches to the desired positions for alarm timing
and volume.
2. For straight through door or wall installation, mark
the center of the 5/16 inch hole in the mounted
base, then remove the base from the door or wall.
3. Drill a 5/16 inch diameter hole through the door or
wall at the marked location.
4. Align the same diameter hole in the secondary unit
base to the back side of the door or wall and
mount.
5. Route the wire from the STI-6400 unit through the
hole and into the secondary unit.
6. Attach the 6 wires to the terminal block pins 2 thru
7 matching wire colors on the terminal block label.
7. Seal the hole around the wires with an effective
fire stop material, if required.
8. Attach the battery in the secondary unit and install
the cover.
9. Cycle the key switch to be sure the LEDâs turn âONâ
and âOFFâ. Leave the LEDâs âONâ until ready to test
the alarm.
10. Attach the battery to the STI-6400 and install the
cover.
11. Close the door and test.
Operation:
1. With the door closed, turn either key switch to arm
the alarm. The LEDâs on both sides of the door
should turn âOFFâ.
2. If the door is opened while the LEDâs are âOFFâ,
then the alarm will sound according to the switch
settings of the STI-6400.
3. To reset the alarm, turn either key to the opposite
position (the LEDâs will turn âONâ), close the door
and turn either key switch again (the LEDâs will turn
âOFFâ).
4. When the system is armed, authorized passage can
be accomplished by turning either key switch until
the LEDâs turn âONâ, and remove key. The door can
now be opened without sounding the alarm. When
passage is complete, close the door, turn the key
switch (the LEDâs will turn âOFFâ). The door alarm
is once again armed.
Addendum for STI-6406 with Dual Access Control
Schematic Diagram:
13 February 2017
- 1 -
Exit StopperÂź
STI-6400 Series
Features
· Alarm helps prevent unauthorized exits/entries through doors.
· Easy to install.
· Select volume, alarm duration and delay settings.
· May be mounted on top, right, left or next to almost any door.
· User can select on-site whether to use an alarm or annunciator.
· Less expensive than heavy horizontal bar type units and practical for all
emergency doors.
· Contact STI for custom applications.
We protect the things that protect you.Âź
- 2 -
Table of Contents
· Warnings and Cautions Page 2 ...........................................................................................
· Warranty Information Page 2 ...............................................................................................
· SpeciïŹcations ......................................................................................................... Page 3
1. Dimensions Page 3 .........................................................................................................
2. Polycarbonate Page 3 .....................................................................................................
3. Electronics Page 3 ..........................................................................................................
4. Remote Horn Page 3 ......................................................................................................
· Circuit Board Set-Up Page 4 ...............................................................................................
· Terminal Strip Layout Page 4 ...............................................................................................
· Switch Settings Page 4 .......................................................................................................
· Alarm Feature Description Page 5 .......................................................................................
· Installation Instructions All Units / STI-6400 Page 5 .............................................................
· Mounting Options Page 6 ...................................................................................................
· STI-6402 Double Door additional install notes Page 6 .......................................................
· STI-6403 Remote Horn additional install notes Page 6 ......................................................
· STI-6404 Double Door with Remote Horn additional install notes Page 6 ..........................
· STI-6405 Exit Stopper with Momentary Reset Page 6 .......................................................
Warnings
All units are recommended for indoor use, not for outdoor use. Unit must be tested periodically
to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. Installer
may need to purchase a simple audio-meter, typically available at your local electronics store,
to measure the sound in areas where the alarm is expected to be heard during normal noise
environment. Results from this test may prove it beneïŹcial to purchase additional exit stopper
units. When purchasing a remote unit (STI-6403 or STI-6404) you will need to periodically test
the connections to make sure audibles function at a sound level to alert staff. Maximum of
three remote alarms may be used in parallel.
All speciïŹcations and information shown are current as of publication and subject to change
without notice.
Warranty Information
· Three year guarantee against breakage of polycarbonate in normal use (one year on electro
mechanical and electronic components).
· Electronic warranty form at www.sti-usa.com/wc14
Produktspezifikationen
Marke: | STI |
Kategorie: | Rauchmelder |
Modell: | -6404 |
Energiequelle: | Gleichstrom |
AC Eingangsspannung: | 9 V |
Warnung Dezibel: | 105 dB |
Akustischer Alarm Typ: | Feuerhorn/Sirene |
Brandmeldesteuerung: | Nein |
Rauchmelder: | Nein |
Kohlenmonoxid (CO)-Detektor: | Nein |
WĂ€rmemelder: | Nein |
Akustisches Notfall-AlarmgerÀt: | Nein |
Brauchst du Hilfe?
Wenn Sie Hilfe mit STI -6404 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Rauchmelder STI
28 August 2024
28 August 2024
7 MĂ€rz 2024
Bedienungsanleitung Rauchmelder
- Rauchmelder Hama
- Rauchmelder Nedis
- Rauchmelder Trust
- Rauchmelder Brennenstuhl
- Rauchmelder Clas Ohlson
- Rauchmelder Cotech
- Rauchmelder REV
- Rauchmelder Bosch
- Rauchmelder Siemens
- Rauchmelder Eminent
- Rauchmelder IKEA
- Rauchmelder Schwaiger
- Rauchmelder Alecto
- Rauchmelder Denver
- Rauchmelder EMOS
- Rauchmelder Gira
- Rauchmelder König
- Rauchmelder MarQuant
- Rauchmelder TFA
- Rauchmelder Blaupunkt
- Rauchmelder Grundig
- Rauchmelder Pyle
- Rauchmelder Vivanco
- Rauchmelder Abus
- Rauchmelder Elro
- Rauchmelder Olympia
- Rauchmelder Smartwares
- Rauchmelder Yale
- Rauchmelder Ferguson
- Rauchmelder Gigaset
- Rauchmelder Nexa
- Rauchmelder GEV
- Rauchmelder Gloria
- Rauchmelder Marmitek
- Rauchmelder Honeywell
- Rauchmelder B/R/K
- Rauchmelder First Alert
- Rauchmelder Flamingo
- Rauchmelder Netatmo
- Rauchmelder Hager
- Rauchmelder Bavaria
- Rauchmelder JUNG
- Rauchmelder Nest
- Rauchmelder Ei Electronics
- Rauchmelder FireAngel
- Rauchmelder Kidde
- Rauchmelder No-Flame
- Rauchmelder Kogan
- Rauchmelder M-e
- Rauchmelder Stabo
- Rauchmelder HQ
- Rauchmelder Busch-Jaeger
- Rauchmelder Swann
- Rauchmelder Sygonix
- Rauchmelder Chuango
- Rauchmelder EQ-3
- Rauchmelder FlammEx
- Rauchmelder Insafe
- Rauchmelder Pyrexx
- Rauchmelder EVE
- Rauchmelder Homematic IP
- Rauchmelder EQ3
- Rauchmelder Electia
- Rauchmelder Somfy
- Rauchmelder Elgato
- Rauchmelder ESYLUX
- Rauchmelder Fito
- Rauchmelder Fito Profi-line
- Rauchmelder Indexa
- Rauchmelder Interlogix
- Rauchmelder KlikaanKlikuit
- Rauchmelder Mercury
- Rauchmelder Satel
- Rauchmelder Steren
- Rauchmelder X-Sense
- Rauchmelder Dahua Technology
- Rauchmelder Inovonics
- Rauchmelder Heatit
- Rauchmelder Pentatech
- Rauchmelder H-Tronic
- Rauchmelder FireX
- Rauchmelder Lupus Electronics
- Rauchmelder System Sensor
- Rauchmelder Malmbergs
- Rauchmelder Chacon
- Rauchmelder Fibaro
- Rauchmelder ORNO
- Rauchmelder WisuAlarm
- Rauchmelder Cavius
- Rauchmelder DSC
- Rauchmelder Cordes
- Rauchmelder Deltronic
- Rauchmelder Minute Man
- Rauchmelder Gewiss
- Rauchmelder Calex
- Rauchmelder Mobeye
- Rauchmelder Qolsys
- Rauchmelder Ajax
- Rauchmelder AngelEye
- Rauchmelder FirstAlert
- Rauchmelder FireHawk
- Rauchmelder ETiger
- Rauchmelder TEF
- Rauchmelder Jalo Helsinki
- Rauchmelder Pristine
- Rauchmelder Jemay
- Rauchmelder Mircom
- Rauchmelder BRK DICON
- Rauchmelder Egardia
- Rauchmelder Frient
- Rauchmelder SAVS
Neueste Bedienungsanleitung fĂŒr -Kategorien-
16 Oktober 2024
16 Oktober 2024
14 Oktober 2024
14 Oktober 2024
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
8 Oktober 2024
7 Oktober 2024
4 Oktober 2024