Steren 550-010 Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Steren 550-010 (4 Seiten) in der Kategorie Schalten. Dieser Bedienungsanleitung war für 4 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/4
R
Manufactured by:
Steren Electronics International, LLC
8675 Miralani Drive, San Diego, CA 92126
1-800-266-3333
www.steren.com
Fast Media
Home Network
Systems
Fast Media
Home Network
Systems
Installation
Guide
Installation
Guide
550-010
Fast Media
Telephone/TV Hub Module
61/2˝ (W) x 43/4˝ (H) x 1˝ (D)
550-010Manual.qxd 7/6/04 3:28 PM Page 1
R
Fast Media Home Network Systems Revised 06/04
2
FastHome™
550-010 Telephone/TV Hub Module Installation Guide
AC/D C A DAPT OR
MODEL: MX 12150-4113
IN PU T:
110V~50/60H z
OUTPUT: 1
5V----- -500mA
MADE IN CHI NA
-+
1 2 3 456
550-010Video Telcom M
aster Modul
e
OUT
RJ3IX
4
3
2
1
TM
INPUT
OUTPUT
1
4
2
5
3
6
POWER
LED
FROM
TELCOM
WAR
NING
!
Welcome to the FastHome™Series
Thank you for purchasing this product, part of the FastHome™Series of Fast Media Home
Network Systems by Steren. You have made an excellent choice for the homeowner. The
FastHome™Series of enclosures and modules provide a quality control center for the wiring
of cable TV, phone/fax/modem, Ethernet, security, sound system and other voice, video, data
and audio devices. Installation is easy and requires only basic tools. By following the instruc-
tions in this guide, you will ensure the proper installation of the FastHome™module.
Product Description
From a centralized location, the Fast Media Telephone/TV Hub Module distributes four
incoming phone/fax/modem lines and also combines and distributes two incoming cable
TV lines to six rooms. The module allows for the insertion of security camera feed using
the RF Modulator Module (550-080) and features an RJ-31X security system connection.
This module also includes a 9VDC, 300mA power supply. All FastHome™modules feature
18-gauge cold rolled steel construction for excellent RFI shielding.
Contents of Package
1. Fast Media Telephone/TV Hub Module
2. 9VDC power supply
3. Installation manual
Tools for Module Installation and Wiring
1. Wire stripper
2. Punchdown tool
3. Personal protective equipment
Introduction
Specifications:
TV Splitter:
•Insertion Loss: 0.0dB 1dB±
•Return Loss: 10dB min.
•Isolation: 20dB min.
Telephone Hub:
•Complies with TIA/EIA 568
CAT5 Standards
About Steren Electronics
Based in San Diego, Steren
has been a leading component
manufacturer for nearly 50 years.
With more than 2,000 items
in our catalog, we supply inter-
connect products and electronics
accessories for home and
commercial use.
The FastHome™Series
of Fast Media Home Network
Systems are produced with
superior design and engineering,
high-quality materials and excep-
tional manufacturing processes,
attributes that are synonymous
with the Steren name.
Safety Instructions
Read these safety instructions before installing this module and follow them carefully.
Keep these instructions handy and refer to them when working on the module.
•Always wear the necessary personal protective gear and follow all
basic precautions and safety procedures when working with wires
and electrical equipment, using power tools or working in unfinished
construction areas.
•Use caution when handling this module. Be careful not to drop the
module because this could affect the performance and/or damage
the module.
•Take extra precautions when working with cables, wires and tools.
Do not install cables and wires that appear to be damaged. Avoid
kinking cables and wires during installation.
•Be careful when using tools that might touch exposed wires or live
electrical contacts.
•To prevent electric shock: 1) do not touch uninsulated wires and terminals that
may still be connected to a live circuit; 2) do not install wires or electrical equipment
during a lightning storm; 3) do not install wires or electrical equipment or their
enclosures near water or locations where water is used (in the kitchen, bathroom,
laundry room, swimming pool, etc.); 4) do not install electrical components or equip-
ment in wet areas, unless specifically rated for moisture.
•Make sure all wires in the modules are properly connected or terminated.
Standard 110
Punchdown Tool
550-010Manual.qxd 7/6/04 3:28 PM Page 2
Fast Media Home Network Systems Revised 06/04
3
FastHome™
550-010 Telephone/TV Hub Module Installation Guide
R
Pre-Installation Instructions
1. After the enclosure has been mounted, determine which modules will be inserted. On a
sheet of paper, diagram the location where each module will be placed. An expansion
module should be placed close to the module with which it interfaces.
2. On the diagram, identify the origin and destination of each cable. Make sure the module
serving each device is safely within a 100ft/30m distance.
Installation Instructions
Note: Do not connect the DC power supply to a power outlet until all wiring has been completed.
1. Identify the enclosure location on which the module will be mounted.
2. Mount the module by inserting the nylon pins into the holes in back of the enclosure and
pressing the pins in. Make sure that the pins are firmly seated and the module is secure.
Wiring Instructions
Note: Module wiring should only be performed by a experienced, licensed electrician. Make
sure all power has been shut off to the equipment and there is no live circuit. Route all cables
through the knock-out holes and bundle with tie wraps or cable straps to ensure safe and
long-lasting connections.
Telephone Hub:
1. Route Category 5 phone cables from the network interface device at the phone companys
demarcation point to the module.
2. Using a wire stripper, strip off about 2 of the cable to expose the wires. Separate the four˝
wire pairs.
3. Using a standard 110 punchdown tool, terminate the tip and ring wires at the “ ”from telcom
side of the telephone hub. Match each wire pair with the color codes on the IDC block
(white/blue: blue pair in line one; white/orange: orange pair in line two; white/green: green
pair in line three; white/brown: brown pair in line four).
4. Perform the stripping and punchdown function for wires at the “ ”output side of the telephone
hub, for 1-6 locations in the home.
5. Tag each cable in the module with its point of destination.
6. Route the cables from the hub to the phone/fax/modem locations in the home and termi-
nate accordingly.
7. Connect the 9VDC power supply cord to the power input jack.
Security System:
This FastHome™module offers a connection to the security system that
can override any phone in use and alert the security service provider of an
emergency. To enable this function, connect the security system cable to
the module’s RJ-31X jack located below the expansion port. (Refer to the
manual from the security system manufacturer for specific instructions and
safety information.)
TV Hub:
1. Connect F-terminated coaxial cable inputs from the cable TV incoming feed and, if insert-
ing security camera feed, the Fast Media RF Modulator Module (550-080) onto the ports
on the “ ” input side of the TV hub.
2. Connect an F-terminated coaxial cable onto each of 1-6 outputs on the output“ ” side of
the hub.
3. Route the cables from the hub to the TV set locations in the home and terminate with
75-Ohm F-connectors.
4. Place 75-Ohm termination caps over unused TV hub ports to improve video reception.
5. Connect the 9VDC power supply cord to the power input jack.
Installation
Sample configuration for telephone,
audio/video, security and Ethernet.
For More Information
about FastHome™and
Fast Media Home Network
Systems, contact:
Steren Electronics International, LLC
8675 Miralani Drive
San Diego, CA 92126
1-800-266-3333
www.steren.com
Copyright 2004 ©
Steren Electronics International, LLC
Printed in China
550-010Manual.qxd 7/6/04 3:28 PM Page 3
Produktspezifikationen
Marke: | Steren |
Kategorie: | Schalten |
Modell: | 550-010 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Steren 550-010 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Schalten Steren
21 August 2024
21 August 2024
17 August 2024
Bedienungsanleitung Schalten
- Schalten Asus
- Schalten Belkin
- Schalten Hama
- Schalten HP
- Schalten LogiLink
- Schalten Manhattan
- Schalten Nedis
- Schalten Philips
- Schalten SilverCrest
- Schalten Panasonic
- Schalten Brennenstuhl
- Schalten Clas Ohlson
- Schalten Cotech
- Schalten Profile
- Schalten ZyXEL
- Schalten Bosch
- Schalten Yamaha
- Schalten Powerfix
- Schalten CSL
- Schalten Eminent
- Schalten Linksys
- Schalten Netgear
- Schalten König
- Schalten PCE
- Schalten Renkforce
- Schalten Trotec
- Schalten Schneider
- Schalten Rex
- Schalten Kaiser
- Schalten Vivanco
- Schalten Abus
- Schalten Elro
- Schalten Smartwares
- Schalten Tesla
- Schalten Perel
- Schalten Nexa
- Schalten Tork
- Schalten GEV
- Schalten Goobay
- Schalten Lindy
- Schalten Tripp Lite
- Schalten Ansmann
- Schalten Mercusys
- Schalten Marmitek
- Schalten Honeywell
- Schalten TRENDnet
- Schalten TP-Link
- Schalten Kathrein
- Schalten Flamingo
- Schalten Alcatel
- Schalten Tiptel
- Schalten Black Box
- Schalten Alpine
- Schalten Techly
- Schalten Ebode
- Schalten Theben
- Schalten Vacmaster
- Schalten GAO
- Schalten Hager
- Schalten Behringer
- Schalten Omnitronic
- Schalten Monoprice
- Schalten Ecler
- Schalten Monacor
- Schalten Huawei
- Schalten JUNG
- Schalten Victron Energy
- Schalten Ei Electronics
- Schalten Edimax
- Schalten Totolink
- Schalten D-Link
- Schalten Sylvania
- Schalten Audiovox
- Schalten B-Tech
- Schalten QNAP
- Schalten SPC
- Schalten Speaka
- Schalten Digitus
- Schalten Sygonix
- Schalten DataVideo
- Schalten Lancom
- Schalten LevelOne
- Schalten Merten
- Schalten APC
- Schalten Eberle
- Schalten Cisco
- Schalten Delta Dore
- Schalten Grässlin
- Schalten Tenda
- Schalten CyberPower
- Schalten Boss
- Schalten IFM
- Schalten Intertechno
- Schalten Elation
- Schalten Ubiquiti Networks
- Schalten Kramer
- Schalten Aeon Labs
- Schalten Intellinet
- Schalten Eaton
- Schalten AV:link
- Schalten Hikvision
- Schalten Vemer
- Schalten PreSonus
- Schalten Planet
- Schalten EnGenius
- Schalten Finder
- Schalten Mikrotik
- Schalten Shimano
- Schalten Homematic IP
- Schalten Berker
- Schalten Dormakaba
- Schalten Emerson
- Schalten Generac
- Schalten Intermatic
- Schalten KlikaanKlikuit
- Schalten Mercury
- Schalten Paladin
- Schalten Provision ISR
- Schalten Robbe
- Schalten SEC24
- Schalten Suevia
- Schalten AMX
- Schalten Triax
- Schalten WHALE
- Schalten Vimar
- Schalten Cudy
- Schalten Siig
- Schalten Electro Harmonix
- Schalten RGBlink
- Schalten Iogear
- Schalten StarTech.com
- Schalten Smart-AVI
- Schalten Dahua Technology
- Schalten PAC
- Schalten Gefen
- Schalten Avocent
- Schalten Legrand
- Schalten Atlantis Land
- Schalten CYP
- Schalten H-Tronic
- Schalten ATen
- Schalten Axing
- Schalten KanexPro
- Schalten SmartAVI
- Schalten Advantech
- Schalten Kraus & Naimer
- Schalten Chacon
- Schalten Juniper
- Schalten Fibaro
- Schalten Phoenix Contact
- Schalten Audac
- Schalten OSD Audio
- Schalten Wentronic
- Schalten SunBriteTV
- Schalten BZBGear
- Schalten Crestron
- Schalten Kemo
- Schalten ORNO
- Schalten Extron
- Schalten Atlona
- Schalten Equip
- Schalten Heitronic
- Schalten Hamlet
- Schalten STI
- Schalten Matrox
- Schalten Blustream
- Schalten Vivolink
- Schalten Mach Power
- Schalten Ernitec
- Schalten Cambium Networks
- Schalten ConnectPro
- Schalten Micro Connect
- Schalten Intelix
- Schalten ICasa
- Schalten Maclean Energy
- Schalten Cooking Performance Group
- Schalten Flic
- Schalten Liberty
- Schalten Noark
- Schalten 2USB
- Schalten KVM-TEC
- Schalten Setti+
- Schalten PureLink
Neueste Bedienungsanleitung für -Kategorien-
15 Oktober 2024
12 Oktober 2024
11 Oktober 2024
8 Oktober 2024
8 Oktober 2024
5 Oktober 2024
4 Oktober 2024
4 Oktober 2024
4 Oktober 2024
3 Oktober 2024