Smeg L23CL Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Smeg L23CL (15 Seiten) in der Kategorie Offener Herd. Dieser Bedienungsanleitung war für 13 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/15
INSTALLATION & USER INSTRUCTIONS
All instructions must be handed to the user for
safekeeping.
MODELS COVERED BY THESE INSTRUCTIONS
P23 LINEAR - P23LIN
P23 CLASSIC - P23CL
L23 LINEAR - L23LIN
L23 CLASSIC - L23CL
L30 FAB - L30FAB
SMEG S.p.A. 42016
Guastalla (RE)
ITALY
WALL MOUNTED HIGH EFFICIENCY GAS FIRE
P23 Linear
P23 Classic
L23 Classic
Please note : Except where otherwise stated, all rights,
including copyright in the text, images and layout of this
booklet is owned by Smeg S.p.A. You are not permitted to
copy or adapt any of the content without the prior written
permission of Smeg S.p.A.
This product is tested and approved to EN14829 : 2007.
L23 Linear
L30 Fab
©2008 Smeg S.p.A.
GB IE
GB-IE-1
•This appliance is a high efficiency, flueless catalytic flame effect gas fire. It provides radiant and convected warmth both effi-
ciently and safely utilising the latest type catalytic converter and burner technology.
•The appliance does not require a flue system of any type as the catalytic converter cleans the flue products to provide a com-
plete combustion system, which is intrinsically safe. It is designed to operate on Natural Gas and is factory set for operation on
the gas type, and at the pressure stated on the appliance data plate.
•The appliance incorporates a combustion monitoring system (Oxygen Depletion System). It must not be adjusted or put out
of operation. If replaced then manufacturer’s original parts must be used.
•This appliance must be installed by a competent person to ensure that the size of the room in which the appliance is to be
installed is sufficient and the ventilation provision for that room is sufficient for the appliance. Details of how to determine the
suitable room size is given in section 3.1 of these instructions and details of how to determine suitable ventilation are given in
section 4.1.
•In the event of gas leakage from the appliance, the gas supply must be turned off at the nearest isolating valve.
•The appliance must be installed in accordance with the following:
•Failure to comply with the above could lead to prosecution and deem the manufac-
turer’s warranty invalid.
•This appliance must be installed in accordance with the rules in force and used only
in a sufficiently ventilated space. The appliance is designed to fit various types of situa-
tions as described in sections 3.0 and 4.0. The appliance must be installed in a correct-
ly sized room (see section 3.1), and the correct purpose provided ventilation must be
provided (see section 4.1).
•On no account should the appliance inlet or outlet openings be blocked or obstruct-
ed in any way (see figure 1). place objects on top of the appliance. makeDo not Do
sure the appliance is installed on a flat wall.
•It should be noted that heaters create warm air currents. These currents move heat
to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall cov-
erings or operating the heater where impurities in the air (such as tobacco smoke, can-
dle smoke etc.) exist, may cause the walls to become discoloured.
•This appliance is intended as a secondary source of heat only and should not be used
in a room without some form of background heating present. If the appliance is used in a room as the sole source of heat, then
condensation may occur on colder surfaces within the room.
•On first light up of a new appliance, burning off of high temperature paint and lubricants may occur for the first few hours of
operation. During this period some smoke may be emitted from the outlet grille, this should be no cause for concern.
Accordingly, the room should be well ventilated with all windows and doors open during this period. During this period the
appliance may cause smoke alarms to sound. If this happens, reset the alarms, but do not remove the batteries.
• WARNING: Due to the nature of this product the area around the top of the appliance (i.e. the grille) gets very hot. Care
should be taken when operating the appliance. The manufacturer of this appliance considers all surfaces as working surfaces
with the exception of the control knob. The guard (glass front) is to prevent risk of fire or injury from burns and no part of
it should be permanently removed. WhereIt Does Not Give Full Protection For Young Children Or The Infirm.
young children, pets, the elderly or infirm are concerned, a suitable fireguard should be used.
•Consult ALL instructions before installation and use of this appliance. This appliance is free from any asbestos material.
Section Contents Page No.
1.0 Important Notes 2
2.0 Appliance Data 3
3.0 Installation Requirements 3
3.1 Room Sizing 3
4.0 Site Requirements 4
4.1 Ventilation 4
5.0 Unpacking the Appliance 5
5.1 Component Checklist 5
6.0 Gas Supply Routes 5
7.0 Fixing the Appliance 6
7.1 Checking the Burner & Spark Gap 6
Section Contents Page No.
8.0 Testing and Commissioning 6
8.1 Operating the Appliance 7
8.2 Setting pressure 7
8.3 Fitting the Decorative Frame 8
9.0 Briefing the customer 8
10.0 Servicing 8
10.1 Servicing the Burner Unit 9
10.2 Pilot Assembly 9
10.3 Catalysts 10
10.4 Testing for Firebox Leakage 10
11.0 Troubleshooting Guide 11
1.0 IMPORTANT NOTES
I N S T A L L A T I O N I N S T R U C T I O N S
•Manufacturers' Instructions.
•Local Codes and/or Regulations.
©2008 Smeg S.p.A.
Note : L30FAB shown from rear as example,
however the air inlet and outlet openings are in
the same relative positions on all models.
Figure 1
Outlet openings :
DO NOT BLOCK
Inlet openings :
DO NOT BLOCK
GB IE
GB-IE-2
Destination
Country
Cat
Inlet Pressure
(mbar)
Max Energy Input
(kW)
Min Energy Input
(kW)
High Burner
Pressure
(±1.5 mbar)
Low Burner
Pressure
(±0.75 mbar)
G20 G25 Gross Net Gross Net Hot Cold Hot Cold
AT, CH, CZ, HR, ES, FI, GB,
GR, IE, IT, NO, SE, SK, TR I2H 20 - 2.60 2.35 1.50 1.35 13.7 13.6 4.3 4.4
DE, PL I2E 20 - 2.60 2.35 1.50 1.35 13.7 13.6 4.3 4.4
BE,FR I2E+ 20 25 2.6/2.4 2.35/2.15 1.5/1.4 1.35/1.25 13.7/16.9 13.6/17.0 4.3/5.6 4.4/5.5
NL I2L - 25 2.40 2.15 1.40 1.25 16.9 17 5.6 5.5
2.0 APPLIANCE DATA
Destination
Country
Cat
Inlet Pressure
(mbar)
Max Energy Input
(kW)
Min Energy Input
(kW)
High Burner
Pressure
(±1.5 mbar)
Low Burner
Pressure
(±0.75 mbar)
G20 G25 Gross Net Gross Net Hot Cold Hot Cold
AT, CH, CZ, HR, ES, FI, GB,
GR, IE, IT, NO, SE, SK, TR
I2H 20 - 2.0 1.8 1.0 0.9 18.7 18.6 4.1 4.0
DE, PL I
2E 20 - 2.0 1.8 1.0 0.9 18.7 18.6 4.1 4.0
BE,FR I2E+ 20 25 2.0/1.85 1.8/1.66 1.0/0.92 0.9/0.83 18.7/23.4 18.6/23.5 4.1/5.3 4.0/5.2
NL I
2L - 25 1.85 1.66 0.92 0.83 23.4 23.5 5.3 5.2
P23 MODELS
Destination
Country
Cat
Inlet Pressure
(mbar)
Max Energy Input
(kW)
Min Energy Input
(kW)
High Burner
Pressure
(±1.5 mbar)
Low Burner
Pressure
(±0.75 mbar)
G20 G25 Gross Net Gross Net Hot Cold Hot Cold
AT, CH, CZ, HR, ES, FI, GB,
GR, IE, IT, NO, SE, SK, TR I2H 20 - 2.0 1.8 1.3 1.17 18.7 18.6 7.4 7.3
DE, PL I2E 20 - 2.0 1.8 1.3 1.17 18.7 18.6 7.4 7.3
BE,FR I2E+ 20 25 2.0/1.85 1.8/1.66 1.3/1.2 1.17/1.08 18.7/23.4 18.6/23.5 7.4/9.3 7.3/9.2
NL I2L - 25 1.85 1.66 1.2 1.08 23.4 23.5 9.3 9.2
P23 MODELS L23 MODELS L30 MODELS
Flow Restrictor Orifice 1.03mm 1.03mm 1.30mm
Oxypilot (Sit/Bray) 9114 9114 9114
Gas Control BM733 BM733 BM733
Gas Inlet Various Various Various
Ignition Piezo Spark Piezo Spark Piezo Spark
Spark Gap (± 1.0mm) 4.0mm 4.0mm 4.0mm
3.0 INSTALLATION REQUIREMENTS
If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue then the old flue must be
sealed off. It will be necessary to ventilate the old flue to prevent condensation and dampness forming, however any air vent used
to ventilate the old flue must not be sited within 500mm of this appliance. If the flue can be ventilated to the outside of the build-
ing then this is usually the best solution. If in doubt then advice should be sought from a local building control officer. The appliance
is designed to be wall mounted. If the appliance is to be mounted on a newly fabricated area of wall that also serves the purpose of
sealing off the old flue then it is very important that there are no holes, gaps or otherwise in this wall that will allow draughts from
the old flue to enter the room, especially directly behind the appliance. Such draughts could affect the performance of the ODS sys-
tem and result in nuisance cutting out, for example. If the gas supply pipe is to enter the appliance from the rear, i.e. emerge from
the wall behind the appliance, then any hole in the wall from which the pipe emerges must be tightly sealed.
In the absence of any local Codes and/or Regulations governing room sizing for type A1AS appliances then the information given
here must be followed.
•P23 and L23 models : The room size should be a minimum of 23m3(e.g. 3.07m x 3.07m x 2.45m or 10'1" x 10'1" x 8').
•L30 models : The room size should be a minimum of 30m3(e.g. 3.5m x 3.5m x 2.45m or 11'6" x 11'6" x 8').
This is to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces
but these spaces must not be separated by a door. To calculate a room size in cubic metres (mNote : 3) divide the room volume
in cubic feet (ft3) by 35.3.
©2008 Smeg S.p.A.
L23 MODELS
L30 MODELS
3.1 ROOM SIZING
GB IE
GB-IE-3


Produktspezifikationen

Marke: Smeg
Kategorie: Offener Herd
Modell: L23CL

Brauchst du Hilfe?

Wenn Sie Hilfe mit Smeg L23CL benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Offener Herd Smeg

Bedienungsanleitung Offener Herd

Neueste Bedienungsanleitung für -Kategorien-