SDD2ELEMTC FLUSH TOP
DOWNDRAFT INSTALLATION INSTRUCTIONS FOR
SEM 11, SEM 21, SEM 71, SEM 81 & DDFMEL motors
Congratulations on your purchase!
Thank you for choosing a Sirius product.
SDD2ELEMTC58 EAN #9351116005344
SDD2ELEMTC88 EAN #9351116005351
SDD2ELEMTC118 EAN #9351116005368
2
SDD2ELEMTC FLUSH TOP
INSTALLATION GUIDE
The symbol on the product or on its packaging indicates that this product
may not be treated as house-hold waste. Instead it shall be handed
over to the applicable collection point for the recycling of electrical and
electronic equipment. By ensuring this product is disposed of correctly,
you will help prevent potential negative consequences for the environment
and human health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed information about
recycling of this product, please contact your local city office, your
household waste disposal service or the shop where you purchased the
product. This appliance is marked according to the European directive
2002/96/EC on waste electrical and electronic equipment (WEEE).
TO THE ATTENTION OF THE USER
INSTALLATION GUIDELINES
APPLIANCE DIAGRAMS
PRE-INSTALLATION CHECKS
INSTALLING THE RANGEHOOD
INSTALLATION INSTRUCTIONS
FOR SEM 11 AND SEM 21
150MM SIDE OR BOTTOM VENTING
FOR SEM 71 AND SEM 81
200MM SIDE OR BOTTOM VENTING
FOR SEM 11, SEM 21, SEM 71, AND SEM 81
150MM / 200MM FRONT OR REAR VENTING
FOR DDFMEL
150MM BOTTOM VENTING
DUCTING FROM MOTOR TO VENT (SEM 11 & 81 ONLY)
ELECTRICAL CONNECTION
HOW THE RANGEHOOD WORKS
CLEANING THE RANGEHOOD
TROUBLESHOOTING
REPLACING THE LIGHT
PARTS LIST
WIRING DIAGRAM
3
3
4
4
5
7
8
10
11
12
12
14
15
15
16
17
20
3
SDD2ELEMTC FLUSH TOP
INSTALLATION GUIDE
TO THE ATTENTION OF THE USER
This rangehood is designed to work with ducted
outside evacuation.
Keep these instructions for use with the appliance. If
the appliance should be sold or passed on to others,
make sure that the instructions are passed on with
it. We thank you for taking note of these suggestions
before installing and using the appliance. They have
been written for your personal safety and the safety
of others.
SAFETY INSTRUCTIONS
These hoods have been designed for personal
use in the home. The appliance must be used by
adults. Make sure that the appliance is out of reach
of children and that they do not use it to play with.
Make sure that children do not operate the controls.
When the appliance is delivered, check the overall
appearance of the packaging. Check PARTS
LIST on page 17 for all included parts prior
to discarding packaging.
Any remarks should be written on the delivery
coupon, of which you keep a copy.
Your appliance is designed for normal domestic
use. It is not designed for commercial or industrial
use, or for purposes other than those for which it
was designed.
Any consequences of or damage from incorrect
installation or incorrect use of the appliance will
not be covered by the manufacturer’s guarantee.
Do not ever change or try to change the
characteristics of this appliance. This would be
a danger. Repairs must be performed only by an
authorised technician.
Always disconnect the hood before carrying out
cleaning or maintenance operations.
Adequately ventilate the room when a rangehood
and other appliances, powered by energy other
than electricity, are used simultaneously, so that
the hood does not suck any combustion fumes.
It is not allowed to cook food over openames
(flambé) or operate gas hobs without pots
or pans on them under the hood itself (the
flames sucked into the hood might damage the
appliance).
Frying under the appliance must be done under
constant supervision as hot oils and fats may
ignite.
Respect the guidelines for cleaning and
replacement of grease filters. Accumulated
deposits of grease are a fire hazard.
WARNING
INSTALLATION GUIDELINES FOR
GAS COOKTOP APPLICATIONS
A minimum 60mm gap must be left between the
stainless steel frame and the nearest edge of the
cooktop.
The minimum distance between the border of the
gas cooktop and the nearest burner must not be
less than 95mm
For the downdraft to operate at a premium, the
distance between the downdraft opening and the
furthest burner shall not exceed 650mm.
Distance between the burners on the side closest
to the downdraft shall not be closer than 165mm.
This appliance must not be used over cook tops
powered by wood or coal or in any case, over
cook tops with power levels that could damage
the appliance.
Never use steam or high-pressure devices
for cleaning your hood (regulations regarding
electrical safety).
Never use the rangehood without the grease
filters.
The minimum distance between the Downdraft
(closed) and the surface above it must be at least
800 mm.
When handling the downdraft, never put your
hands in the field of action of the extractable unit.
At Sirius, we are constantly seeking to improve
our products. We reserve the right to modify their
technical, functional, or aesthetic characteristics
deriving from their upgrading.
Motors manufactured and approved by Sirius only
are to be used at all times. Failure to comply with this
will result in the forfeit of the manufacturer warranty.
The air collected must not be conveyed into a flue
used for smoke or fumes from appliances powered
by anything other than electricity (central heating
systems, bathroom and toilet exhausts, etc.). As
far as discharging exhaust air is concerned, please
follow the guidelines given by competent authorities.

Produktspezifikationen

Marke: Sirius
Kategorie: Afzuigkap
Modell: SDD2ELEMTC118

Brauchst du Hilfe?

Wenn Sie Hilfe mit Sirius SDD2ELEMTC118 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Afzuigkap Sirius

Bedienungsanleitung Afzuigkap

Neueste Bedienungsanleitung für -Kategorien-