Siemens RDG160T Bedienungsanleitung
Siemens
Thermostat
RDG160T
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Siemens RDG160T (2 Seiten) in der Kategorie Thermostat. Dieser Bedienungsanleitung war für 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/2
s
Operating Instructions
en
RDG100T
RDG160T
RDG100T / RDG160T – the electronic room thermostat that allows you to set the ideal room
temperature you want. The thermostat provides Comfort, Economy and Protection mode and, in
addition, an Auto Timer mode with 8 programmable timers. The fan operates either in Automatic
mode or at the selected speed when using Manual mode. You can either rely on the factory settings
or make adjustments that suit your individual needs.
Main display Operating mode
Room temperature Heating mode
Room temperature in degrees
Celsius Electric heater on
Room temperature in degrees
Fahrenheit Cooling
Button lock active Comfort mode
Alert indicator Economy mode
Condensation in the room Auto timer
Temporary timer function
active
Protection mode:
Protection against
frost
Indicator for selecting
mode
Weekday 1 = Monday
7 = Sunday
Operating mode button
Setting time and weekday
Setting the auto timers
Fan mode
Program mode button Current time of day Automatic
T Fan mode button Escape (Cancel) Manual
Low Medium High
Rotary knob Confirmation (OK)
Changing the room temperature
The room temperature setpoint can be adjusted with the rotary knob when
Comfort mode is active or with
Turn the rotary knob clockwise (+) to increase, or counterclockwise (-) to de
crease
the current room temperature setpoint for Comfort mode
The setting range is from 5...40 °C, unless limited by parameters P09 and P10 (for parameter settings,
see reverse side).
Adjusting the fan speed
Low Medium High
Press the fan mode button until the desired fan mode is reached
In Automatic mode
, the fan speed is automatically selected by the thermostat
depending on the setpoint and the actual room temperature.
When the room temperature reaches the setpoint, the fan stops (fac
tory setting) or
keeps running at low speed (P15).
In Manual mode, the fan operates independently and always runs at the same
speed: Low / medium / high
Note:
If desired, you can change the fan mode selector option via P03: Manually only, or manually
including Protection mode. Use P15 to set the fan speed in dead zone.
Changing from heating to cooling mode
Depending on the type of plant, the changeover from heating to cooling (or vice
versa) is made either automatically by a changeover sen
sor or a remote changeover
switch, or manually by pressing the operating mode button (see parameter P01)
To select cooling or heating manually (P01=2), press the operating mode button
until the desired mode appears
With automatic changeover or continuous heating / cooling, symbols /
indicate that the system currently operates in heating or cooling mode
With manual changeover, symbol
appears, indicating that the system currently
operates in heating or cooling mode
Changing the operating mode
Press the operating mode button until symbol
appears, indicating that Protection /
Comfort / Auto Timer / Economy mode is selected.
1. Protection mode
In protection mode, the plant stops operating. If the room temperature falls below
8 °C, heating is switched on however to protect the room against frost
The setpoints for Protection mode can be changed by your HVAC installer if desired:
Changes made by installer: Frost protection: _________ C Heat protection: __________ C
2. Comfort mode
In Comfort mode, the thermostat maintains the setpoint which can be readjusted
with the rotary knob
3. Auto Timer mode
In Auto Timer mode
, the controller automatically switches over between Comfort
and Economy according to the 8 preprogrammed timers
4. Economy mode
When selecting Economy mode, make sure that parameter P02 is set to 2
In Economy mode, the room temperature is maintaine
d at a lower or higher
setpoint, thus saving energy and money! You can change the preselected
setpoint
by adjusting parameters P11 and P12 (for parameter settings, see reverse side)
Important: The setpoint for Economy can be set to OFF. This means that the thermostat is
deactivated! Risk of frost, i.e. no protective heating or cooling function is provided!
Setting the time of day and the weekday
1. Press the program mode button for programming.
2. Press button (OK) to enter the setting mode for the time of day.
3.
The time digits start blinking. Turn the rotary knob clockwise or counterclockwise to set the time
of day.
If the current time of day is in 24-hour format and you wish to change it to the 12-hour format, turn
the knob clockwise passed 23:59 or counterclockwise passed 00:00. Vice versa back to the 24-hour
format.
4. Confirm the time of day by pressing button and the weekday indicator starts blinking.
5. Turn the rotary knob clockwise or counterclockwise to set the current weekday.
6. Confirm the current weekday by pressing button (OK).
7. Press button (Esc) to leave the program mode.
Note:
After a power failure, the time of day starts blinking to indicate power was lost. However, the auto timer continues to
run with the time before the power failure occurred. Select the setting mode to readjust the time if needed.
Setting the programmable timers
The RDG100T
provides 8 programmable timers A1…A8 each of which can be assigned to one or several
days. To set an auto timer, proceed as follows:
1. Press the program mode button twice to select auto timer setting .
2. Turn the rotary knob to the desired timer A1…A8 that you wish to set and press button (OK).
3. Turn the rotary knob to set the Comfort mode start time and confirm by pressing button (OK)
4. Turn the rotary knob to set the Comfort end time
or Economy start time and confirm by pressing
button (OK).
5. Weekday , and blink. Press button (OK) to select or
(Esc) to deselect each day and
advance to the next day.
6.
After the 7th day is set, all selected weekdays blink. Confirm setting for actual timer by pressing
button
(OK) and advance to the next timer. To set the next timer, repeat steps 3 through 6, or
press (Esc) to leave the setting mode.
Notes:
- To save your settings, remember to press OK in step 6 above before pressing Esc to leave the setting mode.
- The timer function can be disabled by setting P02 = 3 or P02 = 4 (only RDG160T)
Viewing the settings
1. Press the program mode button twice to select auto timer setting .
2. Turn the rotary knob to review the 8 auto timers.
3. Press button (Esc) to return to normal operation.
Temporary timer for extended presence or absence
The Comfort and Economy modes can be temporarily extended from 0.5 to 9.5 hours using
the
temporary timer.
1. To set the temporary timer, press and hold the operating mode button for maximum 3 seconds.
While holding the button, turn the rotary knob clockwise or counterclockwise as required.
a) Turn the rotary knob clockwise to extend Comfort mode.
Display: 0....+9:30
b) Turn the rotary knob counterclockwise to extend Economy mode.
Display: 0....-9:30
After the temporary timer has elapsed, the thermostat will resume operation in Auto Timer mode.
Reloading the default timer settings
1. Press the program mode button twice to select auto timer setting .
2. Press button (OK) to enter the timer setting mode.
3. Press the program mode button for at least 3 seconds; then “rES” is displayed.
4. Press button (OK) to confirm reloading the default timer settings, or
(Esc) to leave without
change.
Default
settings
Weekdays Time of day when thermostat is in Comfort mode
Mon(1)- Fri(5) 06:30 – 08:30 (A1) 17:30 – 22:30 (A2)
Sat (6) 08:00-23:00 (A3)
Sun (7) 08:00-22:30(A4)
For the remaining time, the thermostat is in Economy mode.
Timers A5 - A8 are free with no default settings.
Button lock
To lock or unlock the buttons manually, press and hold
the fan mode button for 3
seconds. The buttons are locked or unlocked in this manner if P14 is set to 2
If P14 is set to 1, the thermostat automatically locks the button 10 seconds
after the
last adjustment
Control parameters
If you want to change control parameters, proceed as follows:
1. Press left and right buttons simultaneously for at least 4 seconds.
2. Release them and, within 2 seconds, press the right button again until “P01” is displayed.
3. Select the required parameter by turning the rotary knob.
4. Press button (OK). The current value of the selected parameter starts blinking and
can be changed
by turning the rotary knob.
5. Press button (OK) to confirm the adjusted value, or (Esc) to cancel the change.
If you wish to adjust additional parameters, repeat steps 3 through 5, or press
(Esc) to leave the
parameter setting mode.
No.
Parameter name Default value
Setting range Adj.
P01
Control sequence 2-pipe / 2-stage:
1 = cooling only
4-pipe:
4 = H and C
0 = heating only
1 = cooling only
2 = H/C changeover, manually
3 = H/C changeover, auto
4 = heating and cooling
P02 Mode selection via operating mode button 1
RDG100T: 1, 2
RDG160T: 1…4
1 = Auto / Comfort /
Protection mode
2 = Auto / Comfort / Economy /
Protection mode
3 = Comfort / Protection mode
4 = Comfort / Economy /
Protection mode
P03 Mode selection via fan mode button 0 0 = Auto / Manually
1 = Manually
2 = Auto / Manually /
Protection mode
P04 Selection of °C or °F 0 0 = °C
1 = °F
P05 Sensor calibration 0.0 K – 3 ... 3 K
P06 Standard temperature display 0 0 = Room temperature
1 = Setpoint
P08 Comfort basic setpoint 21 °C 5 ... 40 °C
P09 Minimum setpoint limitation in Comfort mode 5 °C 5 ... 40 °C
P10 Maximum setpoint limitation in Comfort mode 35 °C 5 ... 40 °C
P11 Setpoint for heating in Economy mode
(WheatEco)
15 °C OFF, 5 °C…WcoolEco
P12 Setpoint for cooling in Economy mode
(WcoolEco)
30 °C OFF, WheatEco…40 °C
P13 Electric heater in cooling mode ON OFF = Disabled
ON = Enabled
P14 Button lock 0 0 = Disabled
1 = Automatically
2 = Manually
P15 Fan speed in dead zone
(Comfort mode)
0 0 = Disabled
1 = Stage 1 (H or C)
2 = Stage 1 (Cooling only)
The control parameters displayed depend on the DIP switch settings made
Siemens Switzerland Ltd
Subject to change
B3181.5en
18.09.2013
Produktspezifikationen
Marke: | Siemens |
Kategorie: | Thermostat |
Modell: | RDG160T |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Siemens RDG160T benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermostat Siemens
16 Oktober 2024
7 Oktober 2024
5 Oktober 2024
3 September 2024
1 September 2024
30 August 2024
30 August 2024
29 August 2024
28 August 2024
28 August 2024
Bedienungsanleitung Thermostat
- Thermostat Basetech
- Thermostat Hama
- Thermostat Nedis
- Thermostat SilverCrest
- Thermostat Panasonic
- Thermostat Brennenstuhl
- Thermostat Cotech
- Thermostat Profile
- Thermostat Bosch
- Thermostat AEG
- Thermostat ATAG
- Thermostat Taurus
- Thermostat Velleman
- Thermostat Devolo
- Thermostat Schwaiger
- Thermostat Alecto
- Thermostat Conrad
- Thermostat EMOS
- Thermostat Gira
- Thermostat HomeMatic
- Thermostat Renkforce
- Thermostat Technoline
- Thermostat TFA
- Thermostat Schneider
- Thermostat Corberó
- Thermostat GE
- Thermostat King
- Thermostat Avidsen
- Thermostat Elro
- Thermostat Gigaset
- Thermostat Tesla
- Thermostat Max
- Thermostat Perel
- Thermostat Nexa
- Thermostat Vasco
- Thermostat Fenix
- Thermostat Westfalia
- Thermostat Vaillant
- Thermostat Honeywell
- Thermostat Remko
- Thermostat Junkers
- Thermostat RADEMACHER
- Thermostat AVM
- Thermostat ELV
- Thermostat TP-Link
- Thermostat Zehnder
- Thermostat Lux
- Thermostat De Dietrich
- Thermostat Netatmo
- Thermostat Theben
- Thermostat Tado
- Thermostat Remeha
- Thermostat Saunier Duval
- Thermostat Stiebel Eltron
- Thermostat Truma
- Thermostat Viessmann
- Thermostat Xavax
- Thermostat Hager
- Thermostat Dimplex
- Thermostat Buderus
- Thermostat Noma
- Thermostat JUNG
- Thermostat Boneco
- Thermostat Hunter
- Thermostat Baxi
- Thermostat Wolf
- Thermostat Nest
- Thermostat Magnum
- Thermostat HQ
- Thermostat Itho Daalderop
- Thermostat Carrier
- Thermostat Tylö
- Thermostat Busch-Jaeger
- Thermostat SPC
- Thermostat Gree
- Thermostat Sygonix
- Thermostat Orbis
- Thermostat Econo-heat
- Thermostat EQ-3
- Thermostat RWE
- Thermostat Eberle
- Thermostat BTicino
- Thermostat Bulex
- Thermostat Danfoss
- Thermostat Delta Dore
- Thermostat Fantini Cosmi
- Thermostat Grässlin
- Thermostat Heimeier
- Thermostat IMIT
- Thermostat Klafs
- Thermostat Oventrop
- Thermostat Salus
- Thermostat Seitron
- Thermostat EVE
- Thermostat Ariston Thermo
- Thermostat Elektrobock
- Thermostat Intertechno
- Thermostat Mikoterm
- Thermostat Ferroli
- Thermostat Carel
- Thermostat Daikin
- Thermostat Vemer
- Thermostat EnerGenie
- Thermostat Oregon Scientific
- Thermostat Finder
- Thermostat Homematic IP
- Thermostat Levoit
- Thermostat EQ3
- Thermostat Google
- Thermostat Somfy
- Thermostat Berker
- Thermostat Elgato
- Thermostat Elco
- Thermostat Devi
- Thermostat Drayton
- Thermostat Drayton Erie
- Thermostat Easy Timer
- Thermostat EasyTemp
- Thermostat Eliwell
- Thermostat Emerson
- Thermostat Emmeti
- Thermostat Enda
- Thermostat Eneco
- Thermostat Eqiva
- Thermostat Essent
- Thermostat Etherma
- Thermostat Eurotronic
- Thermostat Extraflame
- Thermostat Frico
- Thermostat Go Green
- Thermostat Helios (Amfra)
- Thermostat Hornbach
- Thermostat Hugo Muller
- Thermostat ICY
- Thermostat IR-V
- Thermostat Itho
- Thermostat Johnson Control
- Thermostat Landis Gyr
- Thermostat Levica
- Thermostat Lowes
- Thermostat Muller
- Thermostat Nefit
- Thermostat Niko
- Thermostat Nobo
- Thermostat OJ ELECTRONICS
- Thermostat Otio
- Thermostat Plieger
- Thermostat Plugwise
- Thermostat Radson
- Thermostat THERMAFLEX
- Thermostat Thermy
- Thermostat ACV
- Thermostat Hive
- Thermostat ThermoSmart
- Thermostat UPM
- Thermostat VDH
- Thermostat Wachendorff
- Thermostat Watts
- Thermostat Webasto
- Thermostat Weishaupt
- Thermostat Worcester-Bosch
- Thermostat Yokis
- Thermostat Z-Wave
- Thermostat Vimar
- Thermostat TrickleStar
- Thermostat Horstmann
- Thermostat Computherm
- Thermostat Heatit
- Thermostat POER
- Thermostat H-Tronic
- Thermostat PECO
- Thermostat Chacon
- Thermostat Emko
- Thermostat Fibaro
- Thermostat Heatmiser
- Thermostat Crestron
- Thermostat ORNO
- Thermostat Optima
- Thermostat HomePilot
- Thermostat Krone
- Thermostat ChiliTec
- Thermostat Arnold Rak
- Thermostat Ouellet
- Thermostat Jumo
- Thermostat Wallair
- Thermostat Maico
- Thermostat Ecobee
- Thermostat Tellur
- Thermostat STI
- Thermostat Cepra
- Thermostat Tru Components
- Thermostat Qubino
- Thermostat Gewiss
- Thermostat Warmup
- Thermostat Sinustec
- Thermostat Rose LM
- Thermostat Agpo Ferroli
- Thermostat Amfra
- Thermostat Aube
- Thermostat AWB
- Thermostat Wattio
- Thermostat Brink
- Thermostat 2Heat
- Thermostat Bryant
- Thermostat Veria
- Thermostat Innogy
- Thermostat ELKO
- Thermostat MundoControl
- Thermostat Bearware
- Thermostat GENERAL Life
- Thermostat Oreg
Neueste Bedienungsanleitung für -Kategorien-
5 Oktober 2024
5 Oktober 2024
5 Oktober 2024
4 Oktober 2024
3 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024
1 Oktober 2024
1 Oktober 2024