Sanus SA206 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Sanus SA206 (16 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/16
SA206 INSTRUCTION MANUAL
We’ll Make It Stress-Free
If you have any questions along the way, just give us a call.
1-800-359-5520. We’re ready to help!
Scan for more information
about this product
san.us/449
2
IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS – PLEASE READ ENTIRE MANUAL PRIOR TO USE
12 VDC
2A Max Total*
5.5mm OD
2.5mm ID
* Maximum DC Output:
12VDC - 2A
5VDC - 2A
Each individual jack can output up to 2A.
Do not exceed maximum ratings.
Master
Power
Switch
IEC Power
Inlet
12A/125V/60HZ
Power Outlet
125 VAC
60 Hz
12A
Power Outlets
5 VDC
2A Max Total*
5.5mm OD
2.1mm ID
3
CAUTION: Avoid potential personal injuries and property damage!
To Reduce the Risk of Electric Shock - Use Only in Dry Locations Indoors!
The input plug of this power tap is intended to serve as the disconnect device, it shall be easily accessible and withdrawn.
This power center does not contain internal circuit breaker protection. INSTALLER MUST ensure that the input of this power center
is connected individually to an electrical service panel that is protected with a UL Listed 20A (Maximum) circuit breaker for overload
protection of the power center.
Not for use with ground-fault circuit-interrupter receptacles or receptacles with indicatior lights or controls.
To reduce the risk of fire or electric shock, do not use this device with a receptacle in which the slot openings to not align with the
blades.
Do not install this device if there is not at least 30 feet (10 meters) or more of wire between the electrical outlet and the electrical service
panel.
All accessories must be grounded.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment
compatible with the maximum ambient temperature (32-104°F/30-40°C) specifi ed by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air fl ow required for safe operation of the
equipment is not compromised.
Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the e ect that
overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern.
Do not use this product for any purpose not explicitly specified by manufacturer.
If you do not understand these instructions, or have doubts about the safety of the installation, assembly or use of this product, contact
Customer Service or call a qualified contractor.
Manufacturer is not responsible for damage or injury caused by incorrect assembly or use.


Produktspezifikationen

Marke: Sanus
Kategorie: Nicht kategorisiert
Modell: SA206

Brauchst du Hilfe?

Wenn Sie Hilfe mit Sanus SA206 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Sanus

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-