SANDPIPER PortaPump SPA 1-1/2-E Bedienungsanleitung

SANDPIPER Pumpe PortaPump SPA 1-1/2-E

Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr SANDPIPER PortaPump SPA 1-1/2-E (5 Seiten) in der Kategorie Pumpe. Dieser Bedienungsanleitung war fĂĽr 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/5
spa105dl3sm Model SPA1½-E and SPA40-E Design Level 3 Page 1
WARREN RUPP, INC., A unit of IDEX Corporation • 800 N. Main Street • Manseld, OH 44902 USA • (419) 524-8388 Fax (419) 522-7867
OPERATING INSTRUCTIONS
THE PUMP: This pump is a totally enclosed, submersible dewatering unit. It is
powered by a 1/3 HP, 12 volt DC 30 AMP motor. Battery clips on the power cord allow
easy connection to any 12 volt vehicle battery.
SWITCHING: The on-off switch is located on the power cord.
CONNECTING TO BATTERY: When connecting the clips to a battery, arcing is
eliminated by keeping the on-off switch in the “off” position. Connect the red battery
clamp to the positive (+) battery terminal. Connect the black battery clamp to ground:
preferably on the vehicle’s engine to a solid, metallic, stationary point. The connection
should be at least 18 inches (480mm) from the battery.
HOSE: Since the pump develops relatively low pressure, it is recommended that
non-collapsible hose be used for maximum pumping rates.
HOISTING & LOWERING: Attach a line to the metal handle on the top of the
pump for hoisting or lowering the unit. Do not use power cable for handling unit.
TO OPERATE: Lower unit into liquid to be pumped and activate switch. Pump
can be run for a few minutes without liquid, however, do not run completely dry for
extended periods. Damage to shaft seal may result.
RUNNING TIME: This unit draws about 30 amperes and can be operated
about 1hour on a fully charged 55 AMP-hour battery and still permit starting of
vehicle under normal conditions. Caution should be used when running time
exceeds 30 or 40 minutes without engine running to recharge battery, particularly
in cold weather when battery efîšżciency is lowered. Battery size (AMP-hour rating)
and the use of other accessories such as lights and radios, etc., must be taken into
consideration for practical running periods without engine running.
OVERLOAD PROTECTION is provided by means of a 40 amp automatic reset
circuit breaker, located under top cover.
SERVICE AND OPERATING MANUAL
PortaPump® Model SPA 1½-E
Model SPA40-E
Design Level 3
Turn o before connecting ff
ba ery clamps to battery. tt
Arcing could result.
DANGER
IMPORTANT
Read these safety warning s
and instructions in thi s
manu plal com etely, before
installation and start-up of the pump. It is
the responsibility of the purchaser to retain
this manual for reference. Failure to comply
with the recommendations stated in thi s
manual will damage the pump, and voi d
factory warranty.
DANGER
DANGER: Not for use with f sluid
that have a flash point below 100°
F ](38° C) [examples: gasoline, alcohol.
Sparking could result in death.
Should unit not operate ,
always check freeness
of grotation of impeller by insertin
scre river thr e basewd ough hol in
plate into slot in end of shaft.
IMPORTANT
Model SPA1½-E and SPA40-E Design Level 3 Page 2 spa105dl3sm
TROUBLE SHOOTING
NOTE: Most common cause of failure to run is due to hardened mud and sand at
impeller. Remove strainer to check.
MOTOR WILL NOT RUN:
1. Poor connection at battery.
2. Impeller locked with foreign material.
3. Insufîšżcient impeller clearance.
4. Damaged power cable or loose connection internally in motor assembly.
5. Bad switch or circuit breaker. Connect power leads direct to motor leads to check.
6. Worn motor brushes or out of position to make contact with armature.
PERFORMANCE LOW:
1. Strainer screen partially plugged.
2. Impeller rubbing. Check freeness of rotation with screwdriver inserted through hole
in base plated into slotted end of shaft.
3. Battery not fully charged.
4. Discharge restriction such as kinked hose or excessive discharge head.
Motor runs backwards:
1. Check wiring for correct polarity.
SERVICE AND REPAIR INSTRUCTION
DISASSEMBLY: Impeller and shaft seal can be inspected and serviced
from lower end of pump by removal of 4 capscrews securing base plate, strainer
screen, and suction cover. Screwdriver slot is provided in end of motor shaft to turn
shaft while holding impeller for removal. This permits removal of impeller without
disassembly of upper motor housing to hold motor shaft. Alternately, there is a shaft
extension with two ats on the rear of the motor for use when the impeller is difcult to
remove. The upper motor cover must be removed to expose this shaft extension.
To service motor remove 4 hex nuts and bump top cover free from housing tube.
Raise sufîšżciently to disconnect power cable connections. Slide housing tube up from
pump casing and motor will be exposed for service or removal.
When servicing the PortaPump and replacing the impeller (part number
444.001.010.) or suction cover (part number 258.001.157.) follow these instructions:The
impeller has been revised to typically require 1 shim (previously 7). The suction cover
has been revised to require 1 gasket (previously 5).
IMPORTANT: Make certain that wire leads are installed per diagram below.
Install top cover as indicated by arrow and instruction on top of cover. Make sure wires
do not contact motor shaft when installing motor cover.
WARRANTY
This unit is guaranteed for a period of 5 years against defective material
and workmanship.
Red Battery
Clamp
Switch
Aux Batt
Red
Motor
Black Black Battery
Clamp (Ground)
Circuit Breaker
510-003-000 Compression Lug
240-001-000 Twist Clamp
spa105dl3sm Model SPA1½-E and SPA40-E Design Level 3 Page 3
1 710-004-330 Screw, Self-Tapping 2
2 258-017-157 Cover, Motor 1
3 545-005-330 Hex Nut 1
4 405-009-000 Handle 1
5 543-001-162 Nut, Gland 2
6 770-007-162 Spacer, Gland 2
7 675-016-360 Ring, Sealing 2
8 545-004-330 Hex Nut 4
9 900-004-330 Lock Washer 4
10 807-011-330** Stud 4
11 270-001-000 Circuit Breaker 1
12 170-028-330 Capscrew, Hex Head 4
13 900-001-330 Lock Washer 8
14 360-001-440 Gasket, Casing 1
15 170-003-115 Capscrew, Hex Head 4
16 444-001-010 Impeller 1
17 740-001-115 Shim As. Req.*
18 258-001-157 Cover, Suction 1
19 612-001-156 Plate, Strainer 1
20 700-001-330 Screen, Strainer 1
21 181-001-155 Casing, Volute, 1½ NPT 1
181-001-155E Casing, Volute, 1½ BSPT (tapered) 1
22 560-022-360 O-Ring 2
23 720-005-000 Seal 1
24 860-011-150** Tube, Casing 1
25 525-005-000 Motor 1
26 200-003-000 Clamp, Cable 1
27 706-007-330 Screw, Machine 1
28 150-036-000 Power Cable Assembly Complete 1
29 900-002-330 Washer, Lock 1
30 510-003-000 Lug, Compression 1
31 240-001-000 Nut, Insulated Wire 1
ITEM TOTAL
NO. PART NUMBER DESCRIPTION RQD.
For Models SPA153F, 12DC3 and SPA15BSP3F, 12DC3: (Not Shown)
10 807-011-330 Stud 2
807-012-330 Stud (replaces 2 807-011-330) 2
325-001-330 Foot, Mounting 2
547-001-330 Stop Nut 5/16-18Vac 2
904-001-330 Washer 2
Service Items: (Not Shown)
475-220-000 Design Level 2 to Design Level 3
Conversion Kit
* Typically 1
** Items 10 & 24 available as a kit #475-132-000
Repair Parts shown in bold face (darker)
type are more likely to need replacement
after extended periods of normal use.
They are readily available from most War-
ren Rupp distributors. The pump owner
may prefer to maintain a limited inventory
of these parts in his own stock to reduce
repair downtime to a minimum.
IMPORTANT: When ordering repair parts
always furnish pump model number, serial
number and type number.
MATERIAL CODES
The Last 3 Digits of Part Number
000…Assembly, sub-assembly; and some purchased
Items
010…Cast Iron
012…Powered Metal
015…Ductile Iron
020…Ferritic Malleable Iron
025…Music Wire
080…CarbonSteel AISI B-1112
100…Alloy 20
110…Alloy Type 316 Stainless Steel
111…Alloy Type 316 Stainless Steel (Electro Polished)
112…Alloy “C”
113…Alloy Type 316 Stainless Steel (Hand Polished)
114…303 Stainless Steel
115…302/304 Stainless Steel
117…440-C Stainless Steel (Martensitic)
120…416 Stainless Steel (Wrought Martensitic)
123…410 Stainless Steel (Wrought Martensitic)
148…Hardcoat Anodized Aluminum
149…2024-T4 Aluminum
150…6061-T6 Aluminum
151…6063-T6 Aluminum
152…2024-T4 Aluminum (2023-T351)
154…Almag 35 Aluminum
155 or 156…356-T6 Aluminum
157…Die Cast Aluminum Alloy #380
158…Aluminum Alloy SR-319
159…Anodized Aluminum
162…Brass, Yellow, Screw Machine Stock
165…Cast Bronze, 85-5-5-5
166…Bronze SAE 660
170…Bronze, Bearing Type, Oil Impregnated
180…Copper Alloy
310…Kynar Coated
330…Zinc Plated Steel
331…Chrome Plated Steel
332…Electroless Nickel Plated
335…Galvanized Steel
336…Zinc Plated Yellow Brass
337…Silver Plated Steel
340…Nickel Plated
342…Filled Nylon
354…Injection Molded #203-40 Santoprene
- Duro 40D ± 5; Color: RED
355…Thermoplastic Elastomer
356…Hytrel
357…Rupplon (Urethane Rubber) Color coded:PURPLE
358…Rupplon (Urethane Rubber)
Color coded:PURPLE
(Some Applications, Compression Mold)
359…Urethane Rubber
360…Buna-N Rubber Color coded: RED
361…Buna-N
363…Viton (Fluorel) Color coded: YELLOW
364…E.P.D.M. Rubber Color coded: BLUE
365…Neoprene Rubber Color coded: GREEN
366…Nitrile, USDA Approved
368…EPDM, USDA Approved
List continued next page
SERVICE AND OPERATING MANUAL
PortaPump® Model SPA 1½-E
Model SPA40-E
Design Level 3
Parts underlined are only available for sale in kits
Parts that are boxed are not available for sale


Produktspezifikationen

Marke: SANDPIPER
Kategorie: Pumpe
Modell: PortaPump SPA 1-1/2-E

Brauchst du Hilfe?

Wenn Sie Hilfe mit SANDPIPER PortaPump SPA 1-1/2-E benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Pumpe SANDPIPER

Bedienungsanleitung Pumpe

Neueste Bedienungsanleitung fĂĽr -Kategorien-