TEST / PAIRING
SELECT
+Hr
SET
iOnce paired please close the
boiler control panel.
The LED will start flashing red.
TEST / PAIRING
+Hr
SELECT SET
RXWBC605 Installation
RXWBC605
1
3
6
2
5
4
Switch off the boiler at its main supply. Remove the outer casing and front fascia to
allow access to the main control panel.
Pull top tab B upwards, then outwards to
remove blanking plate or existing control.
Replace the front fascia and boiler’s
outer casing.
First plug in the connector block C
ensuring correct orientation. Remember
to ensure the block is fully connected.
Remove cover panel A upwards to remove.
Now locate the boiler control’s four hooks
then press in and down. Replace Cover
panel A.
B
A
C
A
8
9
7
The user can also move the switch to the OFF
position; when in this mode, the boiler will not
receive a signal from the RF thermostat.
The user can also move the switch to the
MANUAL ON position; when in this mode, the
boiler will be always turned on and the LED
indicator will also be lit constantly.
A – LED This LED will be on when the thermostat is
demanding heat.
B – Mode Switch:
MANUAL ON / AUTO / OFF
C – SYNC Button - This is used only for pairing the RF
communications.
Now move the switch back to .AUTO
To ensure the boiler control is connected properly, please now move the switch to
MANUAL ON . The boiler should now Fire and the LED on the your boiler
control should illuminate.
RXWBC605 Switch Position
RXWBC605 User Controls
When the switch on the Boiler Module is in
the AUTO position, the boiler control will
automatically receive the RF signal from the
thermostat and control the module output so
that it switches the boiler accordingly.
Before switching the boiler on at its mains supply, ensure the module switch is in the
OFF .position Ø
SYNC Button
Ensure the switch on the RF
integral boiler module is in the
AUTO position.
Gently press and hold the SYNC
button with a blunt object. After 3
seconds the Boiler Control LED will
flash once every second to indicate it
is ready to pair and ready to receive
a signal from the thermostat.
A B C
Quick Guide
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
RT510WBC+ (Thermostat) Button Functions
Introduction
The RT510WBC+ thermostat will switch your heating system on or o, as needed, in accordance
with the time and temperature set by you. It can be used with the RXWBC605 integral plug-
in RF boiler control. The RF boiler control is a direct replacement for the basic time clock or
blanking plate usually supplied with the boiler. Installing the RF boiler control takes minutes.
Once installed, you will benefit from all the control features of the RT510WBC+ thermostat.
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
your device before cleaning it with a dry cloth. This accessory must be tted by a competent person, and
installation must comply with the guidance, standards and regulations applicable to the city, country or
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
available on www.saluslegal.com
+Hr
SELECT
SELECT
SET
SET
+
+
+
Key Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function
Increase button
Decrease button
Select the clock or programme settings
Press to conrm your settings
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
Press the buttons for 3 seconds to enter Installer Mode
Press the buttons for 3 seconds to enter Clock Settings
Box content
Quick Guide 2 x AA Alkaline
Batteries 2 x Fixing Screws
RT510WBC+ Desk Stand
i
RT510WBC+ (Thermostat) Dip Switch Settings
Boiler may re up on pre-heat mode on rst turn on. If it does, it is advisable to
temporarily turn o your pre-heat until installtion is complete.
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
3 Sec
TEST / PAIRING
+Hr
SELECT
3
4
Test the Pairing Process
Pairing Process
Once the LED stops flashing, press the
TEST / PAIRING button for 3 sec.
12
Begin the pairing process
End the pairing process
i
i
During test pairing, boiler control should ash conrming pair. If not, please follow
Pairing Process.
When enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change speciïŹcation, design and materials of products listed in this brochure without prior notice.
Issue Date: February 2018
V016
For PDF Installation guide please go to www.salus-manuals.com
TEST / PAIRING
SELECT
+Hr
3 Sec
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
E: techsupport@salus-tech.com
www.salus-tech.com
PLUS
C
O
M
P
L
I
A
N
T
Internal Temperature
Load Compensation
The DIP Switches can be found on the rear of your thermostat. For all plug-in
boiler receiver applications ensure SW1 is set to RAD.
ON
1 2
ON
NA SPAN
RAD ITLC
Control feature ITLC SPAN
Operation ITLC Internal Temperature
Load Compensation for
improved eciency.
When Span is selected
on DIP switch № 2, the
DIP switch № 1 is not
functional.
+Hr
SELECT SET
Setpoint (desired) temperature
TEST / PAIR ING
Setting Time and Date
Programming
Press SET to return to the Main Screen.
+Hr
+Hr
+Hr +Hr
+Hr
SELECT
SELECT
SELECT SELECT
SELECT
SET
SET
SET SET
SET
+Hr
SELECT SET
You can create personalized programmes for your controller. You have the option to choose
between a 5-2 days programme or a daily one by using the parameter d04 from Installer mode.
Press UP or DOWN to select Weekday/Weekend/
Day and press SELECT.
Press SET to change your programmes.
+Hr
SELECT SET
Press UP or DOWN to set the minutes and
press SELECT to conrm your option.
Press UP or DOWN to set the temperature and
press SELECT to conrm your option.
Follow the same procedure for the next
set of time.
Review the Setpoint (desired) temperature
Press UP or DOWN to review the setpoint
temperature.
Press UP or DOWN to set the temperature.
Actual room temperature
Boost function
Frost protection
Frost Mode ON.
+Hr
SELECT SET
Press OVERRIDE in order to activate the
mode. Press UP or DOWN to set the temperature.
+Hr
+Hr
SELECT SET
SELECT SET
Press SET to conrm the changes.
Press +Hr to activate the
Boost function.
Press the FROST button once to activate the
function.
The Override sign will appear on the Main
screen.
Press +Hr to set boost hours and then press
UP or DOWN to set the boost temperature
for your boost period.
+Hr
SELECT SET
Frost Mode OFF.
+Hr
SELECT SET
Holiday Mode
Press the HOLIDAY button for 3 sec. Press the UP or DOWN button to set the
Holiday period.
+Hr
SELECT SET
+Hr
SELECT SET
Press the HOLIDAY button for 3 sec to exit
Holiday Mode.
Reset function RT510TX+
Remove the batteries without pressing any button. Wait 2 minutes and insert the batteries
again. Your device will be restarted.
+Hr
SELECT SET
+Hr
SELECT SET
+Hr
SELECT SET
+Hr
SELECT SET
+Hr
+Hr
SELECT ET
SELECT SET
+Hr
SELECT SET
Press UP or DOWN to set the hour and press
SELECT to conrm your option.
+Hr
SELECT SET
+Hr
SELECT SET
+Hr
SELECT SET
+Hr
SELECT SET
Permanent Override
1
1
5
3
1
3
1
3
5-2 Days Programme 24h Programme
Weekdays
6 sets of time/channel
Weekends
6 sets of time/channel
Total: 12 settings/week
24h
6 sets of time/channel
Total: 42 settings/week
TEST / PAIR ING TEST / PAIR ING
TEST / PAIR ING
TEST / PAIR ING
TEST / PAIR ING TEST / PAIR ING
TEST / PAIR ING
TEST / PAIR ING
TEST / PAIR ING
TEST / PAIR ING
TEST / PAIR ING TEST / PAIR ING
TEST / PAIR ING
TEST / PAIR ING
TEST / PAIR ING TEST / PAIR ING
Continue with the same steps for setting
the Day.
Press the FROST button once to deactivate
the function.
Temporary Override
6
1 2
4
56
3
2
+Hr
SELECT SET
Press SET to conrm the changes.
+Hr
SELECT SET
3
TEST / PAIR ING TEST / PAIR ING
4
2
4
2
4
2
4
3sec
3sec
Press the buttons together for 3 sec.
Press UP or DOWN to select the hour format
and then press SELECT to conrm your
option.
Press UP or DOWN to select the hour
and then press SELECT to conrm your
option.
Press UP or DOWN to select the minutes
and then press SELECT to conrm your
option.
+Hr
SELECT SET
+Hr
SELECT SET
3 Sec3 Sec
+Hr
SELECT SET
+Hr
SELECT SET
1
3
TEST / PAIR ING
2
4
i
ii
After you have done all the changes, please press SET to conrm all your choices
and to return to the Main Screen.
The Frost protection temperature can be reviewed by pressing the UP button
once, but can only be changed in Installer Mode.
iYou can also exit Holiday Mode by setting the days to zero.
When you want to change the batteries your device will use the internal
memory to backup your settings. You have 30 seconds to change the
batteries before losing your settings.
dxx Function Parameter Default value
d01 Temperature display increments 0.1°C or 0.5°C 0.5°C
d02 Temperature oset +/- 3.0°C 0.0°C
d03 Frost Protection setpoint temperature 5.0°C - 17.0°C 5.0°C
d04 Programmer selection 5/2 or 24 hr (7d) 52d
Installer Mode
Press the three buttons together
simultaneously for 3 seconds.
+Hr
SELECT SET TEST / PAIR ING
+Hr
SELECT SET
3 Sec
3 Sec
G
3 Sec
NOTE:
If you do not notice the “low battery” symbol displayed on the screen in time, it will shut
down. In this case, after removing the old batteries, it is necessary to wait 5 minutes before
inserting the new batteries. Otherwise, it is possible that a condenser will remain partially
discharged and it can prevent the thermostat from restarting.