Commercial Condensing Tankless
Water Heater Installaon and
Operaon Manual
— Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instrucons.
If you cannot reach your gas supplier, call the re department.
— Installaon and service must be performed by a qualied installer, service agency or the gas supplier.
If the informaon in these instrucons is not followed exactly, a re or explosion
may result causing property damage, personal injury, or death.
WARNING
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
This manual provides informaon on the installaon, operaon, and maintenance of the water heater. For proper
operaon and safety, it is important to follow the instrucons and adhere to the safety precauons.
A licensed professional must install the water heater according to the exact instrucons in this manual.
The consumer must read the enre manual to properly operate the water heater and to have regular maintenance
performed.
FOR INDOOR APPLICATIONS ONLY
C199i .................... REU KBD3237FFUDC- -US
FOR OUTDOOR APPLICATIONS ONLY
C199e .................... REU KB3237WDC- -US
ANSI Z21.10.3 ● CSA 4.3
SANITATION
Low Lead Content
NSF/ANSI 372
C US
U306 1971(00)-
2 C199 Manual
Table of Contents
This is the safety alert symbol. This symbol alerts you to potenal hazards that can kill or hurt you
and others.
Indicates an imminently hazardous situaon which, if not avoided, will result in personal
injury or death.
Indicates a potenally hazardous situaon which, if not avoided, could result in personal
injury or death.
Indicates a potenally hazardous situaon which, if not avoided, could result in minor or
moderate injury. It may also be used to alert against unsafe pracces.
DANGER
CAUTION
WARNING
Table of Contents ..................................................... 2
Safety Behaviors and Pracces for the
Consumer and Installer ............................................ 3
Installaon Instrucons
(for the licensed professional) 4 .............................
Prepare for Installaon ...................................... 5
Determine Installaon Locaon ........................ 6
Combuson Air Requirements (Common Vent &
Commercial Hybrid System Applicaons Only) ..... 7
Freeze Protecon ............................................. 13
Checklist to Determine Installaon Locaon ... 14
Mount to Wall.................................................. 14
Installaon of Venng (indoor models only) ... 15
Venng Guidelines and Conguraons ......16 22-
Twin Pipe PVC/CPVC Vent Installaon ........ 23 40-
Condensate (indoor models only).................... 41
Checklist for Venng and Condensate
(indoor models only) ........................................ 41
Installaon of Plumbing ................................... 42
Checklist for Plumbing ..................................... 45
Installaon of Gas Supply ................................ 45
Connect Electricity ........................................... 47
Adjustment for High Altude Installaons ...... 47
Adjustment for Vent Length
(indoor models only) .............................................. 47
Checklist for Gas and Electricity ....................... 47
Installaon of Temperature Controller ............ 48
Final Checklist................................................... 50
Technical Data ........................................................ 51
Specicaons ................................................... 51
Dimensions....................................................... 52
Pressure Drop and Water Flow Curves ............ 53
Ladder Diagram................................................ 54
Operaon Instrucons ....................................... 55
Consumer Operaon Guidelines for the
Safe Operaon of your Water Heater .................... 56
How to Use the Temperature Controller ...............57
How to Set the Temperature .................................. 58
Diagnosc Codes ....................................................60
Required Maintenance ........................................... 63
Freeze Protecon and Winterizaon ............... 64
Flushing the Heat Exchanger ............................ 65
Manual Draining of the Water Heater ............. 66
State Regulaons .................................................... 67
Replacement Parts ................................................. 68
Warranty ................................................................. 69
French Version ........................................................ 72
Important Safety Informaon
Safety Denions
NOTICE: Rinnai somemes shares customer contact informaon with businesses that we believe provide
products or services that may be useful to you. By providing this informaon, you agree that we can
share your contact informaon for this purpose. If you prefer not to have your informaon shared with
these businesses, please contact customer service and ask not to have your informaon shared. We
will however, connue to contact you with informaon relevant to the product(s) you registered and/
or your account with us.
If you have any quesons or feel that the manual is incomplete contact Rinnai at 1 800 621 9419--- .
C199 Manual 3
CAUTION
BURN HAZARD. Hot exhaust and vent may cause
serious burns. Keep away from the water heater
unit. Keep small children and animals away from
the unit.
Hot water outlet pipes leaving the unit can be hot
to touch.
Safety Behaviors and Pracces for the Consumer and Installer
Before operang, smell all around the appliance
area for gas. Be sure to smell next to the oor
because some gas is heavier than air and will sele
on the oor.
Keep the area around the appliance clear and free
from combusble materials, gasoline, and other
ammable vapors and liquids.
Combusble construcon refers to adjacent walls
and ceiling and should not be confused with
combusble or ammable products and materials.
Combusble and/or ammable products and
materials should never be stored in the vicinity of
this or any gas appliance.
Always check the water temperature before
entering a shower or bath.
To protect yourself from harm, before performing
maintenance:
Turn o the electrical power supply by
unplugging the power cord or by turning o the
electricity at the circuit breaker. (The
temperature controller does not control the
electrical power.)
Turn o the gas at the manual gas valve, usually
located immediately below the water heater.
Turn o the incoming water supply. This can be
done at the isolaon valve immediately below
the water heater or by turning o the water
supply to the building.
WARNING
Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it; call a
licensed professional. Force or aempted repair
may result in a re or explosion.
Do not use this appliance if any part has been under
water. Immediately call a licensed professional to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
Do not use substute materials. Use only parts
cered for the appliance.
Should overheang occur or the gas supply fail to
shut o, turn o the manual gas control valve to the
appliance.
Do not adjust the DIP switch unless specically
instructed to do so.
Do not use an extension cord or an adapter plug
with this appliance.
Any alteraon to the appliance or its controls can be
dangerous and will void the warranty.
Proper venng is required for the safe operaon of
this appliance.
California law requires this noce to be provided:
California Proposion 65:
This product contains chemicals known to the state of California to cause cancer, birth defects, or other
reproducve harm.
WARNING
Produktspezifikationen
Marke: | Rinnai |
Kategorie: | Durchlauferhitzer und Boiler |
Modell: | Commercial C199IP |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Rinnai Commercial C199IP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Durchlauferhitzer und Boiler Rinnai
21 Juni 2024
21 Juni 2024
14 Juni 2024
14 Juni 2024
28 Mai 2024
27 Mai 2024
17 Mai 2024
9 Mai 2024
21 April 2024
4 April 2024
Bedienungsanleitung Durchlauferhitzer und Boiler
- Durchlauferhitzer und Boiler Infiniton
- Durchlauferhitzer und Boiler Philips
- Durchlauferhitzer und Boiler Panasonic
- Durchlauferhitzer und Boiler Adler
- Durchlauferhitzer und Boiler Bosch
- Durchlauferhitzer und Boiler AEG
- Durchlauferhitzer und Boiler Siemens
- Durchlauferhitzer und Boiler ATAG
- Durchlauferhitzer und Boiler Buffalo
- Durchlauferhitzer und Boiler Electrolux
- Durchlauferhitzer und Boiler Fagor
- Durchlauferhitzer und Boiler Gorenje
- Durchlauferhitzer und Boiler Teka
- Durchlauferhitzer und Boiler Taurus
- Durchlauferhitzer und Boiler Vox
- Durchlauferhitzer und Boiler BEKO
- Durchlauferhitzer und Boiler Hotpoint
- Durchlauferhitzer und Boiler Inventum
- Durchlauferhitzer und Boiler Solac
- Durchlauferhitzer und Boiler Atlantic
- Durchlauferhitzer und Boiler Corberó
- Durchlauferhitzer und Boiler GE
- Durchlauferhitzer und Boiler Haier
- Durchlauferhitzer und Boiler Kelvinator
- Durchlauferhitzer und Boiler Midea
- Durchlauferhitzer und Boiler Rommer
- Durchlauferhitzer und Boiler Svan
- Durchlauferhitzer und Boiler Hitachi
- Durchlauferhitzer und Boiler Fakir
- Durchlauferhitzer und Boiler Waeco
- Durchlauferhitzer und Boiler Vaillant
- Durchlauferhitzer und Boiler Qlima
- Durchlauferhitzer und Boiler Junkers
- Durchlauferhitzer und Boiler Cata
- Durchlauferhitzer und Boiler De Dietrich
- Durchlauferhitzer und Boiler Remeha
- Durchlauferhitzer und Boiler Stiebel Eltron
- Durchlauferhitzer und Boiler Truma
- Durchlauferhitzer und Boiler Viessmann
- Durchlauferhitzer und Boiler Dimplex
- Durchlauferhitzer und Boiler Buderus
- Durchlauferhitzer und Boiler Baxi
- Durchlauferhitzer und Boiler Eccotemp
- Durchlauferhitzer und Boiler Clage
- Durchlauferhitzer und Boiler Tesy
- Durchlauferhitzer und Boiler Worcester
- Durchlauferhitzer und Boiler Ariston Thermo
- Durchlauferhitzer und Boiler La Nordica
- Durchlauferhitzer und Boiler Ferroli
- Durchlauferhitzer und Boiler Nibe
- Durchlauferhitzer und Boiler Noveen
- Durchlauferhitzer und Boiler Orbegozo
- Durchlauferhitzer und Boiler Schäfer Heiztechnik
- Durchlauferhitzer und Boiler Edilkamin
- Durchlauferhitzer und Boiler Jocel
- Durchlauferhitzer und Boiler Morco
- Durchlauferhitzer und Boiler Nefit
- Durchlauferhitzer und Boiler Oertli
- Durchlauferhitzer und Boiler Quantum
- Durchlauferhitzer und Boiler Technika
- Durchlauferhitzer und Boiler Thermoflow
- Durchlauferhitzer und Boiler Thermona
- Durchlauferhitzer und Boiler ACV
- Durchlauferhitzer und Boiler Biasi
- Durchlauferhitzer und Boiler OSO
- Durchlauferhitzer und Boiler IQE
- Durchlauferhitzer und Boiler Neopower
- Durchlauferhitzer und Boiler Rheinstrom
- Durchlauferhitzer und Boiler Amtrol
- Durchlauferhitzer und Boiler Joven
- Durchlauferhitzer und Boiler Rheem
- Durchlauferhitzer und Boiler LERAN
- Durchlauferhitzer und Boiler Kospel
- Durchlauferhitzer und Boiler Gleamous
- Durchlauferhitzer und Boiler Airthereal
- Durchlauferhitzer und Boiler Intellihot
- Durchlauferhitzer und Boiler Solahart
- Durchlauferhitzer und Boiler My-PV
- Durchlauferhitzer und Boiler ENEFT
Neueste Bedienungsanleitung für -Kategorien-
28 Juni 2024
17 Juni 2024
17 Juni 2024
11 Juni 2024
28 Mai 2024
28 Mai 2024
23 Mai 2024
21 Mai 2024
21 Mai 2024