Regency Mansfield L850B ST Bedienungsanleitung

Regency Heizung Mansfield L850B ST

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Regency Mansfield L850B ST (40 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/40
Model: MANSFIELD L850B ST
Owners &
Installation
PLEASE KEEP THESE INSTRUCTIONS FOR
FUTURE REFERENCE
Manual
February 10, 2023
919-638l
WARNING:
Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to this manual. For assistance
or additional information consult an authorised installer, service agency
or the distributor.
It is highly recommended for protection of infants and inrm to place
a secure safety guard in front of this appliance when in operation.
SEE-THRU WOOD FIREPLACE
FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.
99 COLEMANS ROAD, DANDENONG SOUTH
VICTORIA 3175
2Manseld L850B ST Woodre
Thank you for purchasing a
REGENCY FIREPLACE PRODUCT
The pride of workmanship that goes into each of our products will give you years of trouble-free
enjoyment. Should you have any questions about your product that are not covered in this manual,
please contact the in your area.REGENCY DEALER
Keep those burning.REGENCY FIRES
SAFETY NOTE: If this wood re is not properly installed, a house re may result. For your safety,
follow the installation instructions, contact local building, re ocials, or authority having jurisdic-
tion about restrictions and installation inspection requirements in your area.
The authority having jurisdiction should be consulted before installation to determine the need to
obtain a permit.
CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVA-
TIVES, METAL FOILS, COAL, PLASTIC, GARBAGE, SULPHUR OR OIL WILL DAMAGE THE FIRE
AND ATMOSPHERE.
"This wood heater is designed to burn natural wood only. Higher eciencies and lower emissions
generally result when burning air dried seasoned hardwoods, as compared to green or freshly
cut hardwoods."
ONLY CLEAN APPLIANCE WITH A DAMP CLOTH
(NEVER WHEN UNIT IS HOT)
DO NOT USE ANY ABRASIVE CLEANERS
DO NOT BURN (WILL VOID WARRANTY):
• Treated wood • Tea Tree • Oil Based woods • Coal
• Cardboard • Solvents • Colored Paper • Household Waste
Manseld L850B ST Woodre 3
table of
contents
Copy of Data Badge 4 ..................................................
Unit Dimensions 5 ........................................................
Before Installing Your Fireplace 6 ..................................
INSTALLATION 7 ....................................................
Safety Guidelines and Warnings/Cautions 7 ....................
Unit Dimensions 8 ........................................................
Reduced Clearance Box Dimensions 8 ............................
Wood Fireplace Specics and Minimum Clearances ......9
Flue Clearances to Combustibles 10 ..............................
Optional Base Frame 11 ..............................................
Flue Requirements 12 ..................................................
Installation Instructions - Unit Preparation/Framing 14 ...
Installation Instructions -Unit Preparation/Framing and
Wall Finishing 17 ..........................................................
Flue & Chimney Requirements 18 ..................................
Optional Fan Kit Installation 20 .....................................
Fan Duct Extension Kit 22 .............................................
Wiring Diagram 22 .......................................................
Optional Outside Air Kit Installation 23 .........................
Firebrick Installation 24 ...............................................
MAINTENANCE 25 ..................................................
Appliance Maintenance 25 ............................................
Creosote 25 .................................................................
Ash Removal 25 ...........................................................
Glass Installation 25 .....................................................
Maintenance 25 ...........................................................
Glass Maintenance 25 ..................................................
Door Latch Adjustment 25 ............................................
OPERATING INSTRUCTIONS 26 .............................
Operating Instructions 26 .............................................
Air Slide Control 26 ......................................................
Wood Storage 26 .........................................................
Lighting the Appliance & the First Few Fires 27 ..............
Troubleshooting 28 ......................................................
PARTS LIST 29 ........................................................
WARRANTY 31 ........................................................
Installation of Appliance Checklist 31 .............................
Warranty 32 ................................................................
4Manseld L850B ST Woodre
data badge
This is a copy of the data badge that accompanies
each L850B ST Fireplace. We have included a copy
of the contents here for your review.
NOTE: Regency units are constantly being
improved. Check the data badge on the unit
and if there is a dierence, the data badge on
the unit is the correct one.
COPY OF DATA BADGE
Model: MANSFIELD L850B ST
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2021 2022 2023 2024 2025
TESTED BY: AUSTRALIA SOLID FUEL
TESTING PTY LTD.
3 GARDEN STREET, MORWELL VIC 3870
MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD: 13 kW
OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD: 63%
Date of Manufacture:
Serial
Number
919-639b
444
WHEN TESTED IN ACCORDANCE WITH AS/NZS 4012:2014 & AS/NZS 4013:2014
PARTICULATE EMISSION FACTOR: 1.3 g/kg
CATALYTIC COMBUSTOR: NO
TEST REPORT NUMBER: ASFT16012 -1
MAKE: REGENCY
TYPE: FIREPLACE INBUILT
MANUFACTURER/DISTRIBUTOR: FIREPLACE PRODUCTS AUSTRALIA PTY. LTD.
99 COLEMANS ROAD, DANDENONG SOUTH VIC. 3175
Manseld L850B ST Woodre 5
dimensions
UNIT DIMENSIONS
645
499
569
1098
927
493
499
1193
790
310
300 927
1227
1287
1073
1098
Note: All dimensions in millimetres.
6Manseld L850B ST Woodre
installation
BEFORE INSTALLING YOUR FIREPLACE
1) Please read this entire manual before you install and use your new wood replace. Failure to follow instructions may result in property damage, bodily
injury or even death. Install and use only in accordance with manufacturer’s installation and operating instructions.
2) Check your local building codes - Building Inspection Department. You may require a permit before installing your replace. Be aware that local codes
and regulations may override some items in the manual.
3) Notify your home insurance company that you plan to install a wood heater.
4) THE FIREPLACE CAN GET VERY HOT. DO NOT INSTALL, PLACE OR POSITION TV’S, PAINTINGS, PICTURES, CANDLES, FURNITURE, DRAPES OR ANY
OTHER COMBUSTIBLE ITEMS ON THE WALL OR NEAR THE FIREPLACE.
5) ENSURE THERE ARE NO EXHAUST FANS WITHIN THE VICINITY OF THE FIREPLACE AS THIS CAN CAUSE THE FIREPLACE TO EMIT FUMES BACK INTO
THE ROOM.
6) ENSURE THERE IS ADEQUATE AIR SUPPLY WITHIN THE ROOM/AREA THE FIREPLACE IS BEING INSTALLED IN TO ENSURE PROPER OPERATION OF THE
FIREPLACE. INSTALL OPTIONAL OUTSIDE AIR KIT IF IN DOUBT.
7) EVALUATE THE LOCATION OF YOUR FIREPLACE AND OPTIONAL COMPONENTS. IT IS VERY IMPORTANT TO DETERMINE HOW THE FIREPLACE IS GOING
TO BE FINISHED. THE FEATURES YOU WOULD LIKE TO INCORPORATE SUCH AS FINISH TRIM, OUTSIDE AIR AND FAN KIT NEED TO BE EVALUATED
BEFORE COMMENCING INSTALLATION.
8) DETERMINE WHAT THE THICKNESS OF YOUR DESIRED NON-COMBUSTIBLE FINISHING MATERIALS WILL BE INCLUDING THE NON-COMBUSTIBLE BOARD.
THIS PREDETERMINED THICKNESS WILL DICTATE THE POSITION OF THE NAILING STRIPS, FRAMING AND OVERALL FINAL LOOK OF YOUR FIREPLACE.
9) Your replace is heavy and requires two or more people to move it safely. The replace can be badly damaged by mishandling and or injury can occur.
10) Do not connect the replace to a ue system servicing another appliance or an air distribution duct.
WARNING: CARELESS INSTALLATION IS THE MAJOR CAUSE OF SAFETY HAZARDS. CHECK ALL LOCAL BUILDING AND SAFETY CODES BEFORE INSTALLATION
OF UNIT.
THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES.
Regency Fireplaces are constructed with the highest quality materials and assembled under strict quality control procedures that ensure years of trouble free
and reliable performance.
It is important that you read this manual thoroughly and fully understand the safe installation and operating procedures. The more you understand the way
your Regency Fireplace operates, the more enjoyment you will experience from knowing that your unit is operating at peak performance.
Manseld L850B ST Woodre 7
installation
1) Never use petrol, petrol type lantern fuels, kerosene, charcoal lighter
fuel, or similar liquids to start or ‘freshen up’ a re in your heater.
Keep all such liquids well away from the heater while it is in use.
2) Keep the door closed during operation and maintain all seals in
good condition.
3) Do not burn any quantities of paper, garbage, and never burn
ammable uids such as petrol, naptha or engine oil in your heater.
4) If you have smoke detectors, prevent smoke spillage as this may
set o a false alarm.
5) Do not overre heater. If the ue, ue bae or the heater top begin
to glow, you are overring. Stop adding fuel and close the air slide
control and both doors. Overring can cause extensive damage
to your heater including warpage and premature steel corrosion.
Overring will void your warranty.
6) Do not permit creosote or soot build-up in the ue system. Check
and clean ue at regular intervals. Failure to do so can result in a
serious ue re.
7) Your Regency heater can be very hot. You may be seriously burned
if you touch the heater while it is operating, keep children, clothing
and furniture away. Warn children of the burn hazard. For safety
reasons a guard around the re is recommended.
8) The heater consumes air while operating, provide adequate ventilation
with an air duct or open a window while the heater is in use or use
optional outside air kit.
9) Do not use grates or andirons or other methods for supporting fuel.
Burn directly on the base or bricks where supplied.
10) Open the air slide control fully for 10 to 15 seconds prior to slowly
opening the door when refuelling the re.
11) Your wood re should burn dry, hardwood, rewood only. The use of
cut timber, plywood, “mill ends”, etc. is not allowed as this fuel can
easily overheat your wood re. Evidence of excessive overheating
will void your warranty. As well, a large portion of sawmill waste
is chemically treated timber, which is illegal to burn in many areas.
Salt drift wood and chemically treated re logs also must not be
burned in your wood re.
WARNING
Ensure that curtains, blinds and drapes cannot extend to or anywhere
near the re as this could cause an extremely dangerous operating
condition.
These must be secured by any means possible.
Examples not limited to :
If a window or door is opened, the wind/breeze could cause them to move.
Physical movement by an adolescent child.
WARNING: THE APPLIANCE AND FLUE-SYSTEM SHALL BE INSTALLED
IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE
REQUIREMENTS OF THE RELEVANT BUILDING CODE OR
CODES. UNIT FLUEING REQUIRES A MINIMUM OF 50 MM
CLEARANCE TO COMBUSTIBLES.
WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS
STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/
NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY.
I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE
PLATE WITH THE MARKING 'TESTED TO AS/NZS 4013'.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN
APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED
FOR COMPLIANCE WITH AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS
FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL
SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS
CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE
MANUFACTURER SHOULD BE CONSULTED IN THE FIRST
INSTANCE.
CAUTION: CRACKED AND BROKEN COMPONENTS, e.g. GLASS
PANELS OR FIREBRICKS & BAFFLE BRICKS, ETC. MAY RENDER
THE INSTALLATION UNSAFE.
WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT
BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS
CONSIDERED AS BREACHING AS/NZS 4013.
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO
START OR REKINDLE THE FIRE.
WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN
THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING.
WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION
CLEARANCES.
WARNING: DO NOT USE AS AN OPEN FIRE OR OPERATE WITH THE
DOOR OPEN.
WARNING: OPEN AIR SLIDE CONTROL BEFORE OPENING FIRE DOOR.
CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED
AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS
CAUTION: THE USE OF SOME TYPES PRESERVATIVE-TREATED WOOD
AS A FUEL CAN BE HAZARDOUS
CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED WITH
CRACKED GLASS
SAFETY GUIDELINES AND WARNINGS/CAUTIONS
8Manseld L850B ST Woodre
installation
UNIT DIMENSIONS
REDUCED CLEARANCE BOX DIMENSIONS
Dimensions
The outside dimensions of the Mansfield L850B ST including the Reduced
Clearance Box is as follows:
Width = 1073 mm
Depth = 499 mm
Height = 927 mm
Height of optional Base Framing Kit = 300mm
Note: Base is non-combustible and needs assembly
Height of reduced clearance box o the ground should be a minimum of
300mm and supported by a non-combustible stand able to support 332kg.
Note: Depth is determined by the position of the nailing strips and
thickness of non-combustible nished wall material.
Flue
The ue must be a Regency triple skin
type with approved cowl and must
extend a minimum of 4.6 metres above
the top of the oor protector.
Optional Ducting
2 x Optional fan forced ducting kit are
available, using 150 mm ducting to a
max run of 9 metres to channel warm
air to another location.
927
499
1073
Manseld L850B ST Woodre 9
installation
WOOD FIREPLACE SPECIFICS AND MINIMUM CLEARANCES
Framing and Finishing Guide
Finishing material must be ush with the outer edge of Clean Edge
Finish – see page on Installation Instructions.
Finishing material must not protrude past the outer edge of Clean
Edge Finish – see on Installation Instructions.
All walls of the enclosure must be a minimum of 9 mm non-combustible
material compliant with AS1530-1 and AS1530-3.
Please note: when selecting non-combustible material, wall temperatures
can exceed 250oC. Clean edge trim standos top and both sides are set at
22mm. Leave a minimum 10mm gap from bottom of clean edge trim to non
combustible material to allow for expansion and contraction.
*Enclosure Depth = 569 mm total thickness of nishing material on each
side of the heater.
*Maximum nishing material thickness is 15 mm on the front & back
face of the enclosure to ensure a minimum air gap of 20 mm between the
face of the reduced clearance box and the back face of the nishing material
on each side of the heater.
Enclosure depth is noted with nailing strips (top & sides) set for the correct
total thickness of non-combustible nished wall material.
Floor Protector Requirements
Floor protector needs to be 9mm thick non-combustible material, 1220mm
wide and 300mm deep extending out from door on both sides. We do recom-
mend that your non-combustible oor protector extends 900mm in front of
the unit. This allows the oor to be protected when the door is fully open in
case of ember drop.
The appliance must be installed on a non-combustible stand 300mm above
the oor protector.
NEW OR EXISTING
CEILING
50mm
CLEARANCE IS
REQUIRED
TO FLUEING
WHEN PASSING
THRU
COMBUSTIBLE
CEILING.
VENTILATION
GRILL
REQUIRED
MINIMUM
OPEN AREA
OF 8000mm2
MINIMUM OF
1080mm
ABOVE FUEL
LOADING
DOOR
VENTILATION
GRILL REQUIRED
MINIMUM OPEN
AREA OF 8000mm2
700mm
700mm
LOWER
UPPER
ON ONE SIDEO
ONLY
ON ONE SIDEO
ONLY
9mm FLOOR PROTECTOR
THICKNESS EXTENDING 300MM
(BOTH SIDES OF FIREPLACE)
Fireplace Enclosure
(see above)
1150mm
1580mm
300mm
300mm
Combustible Wall
Enclosure Depth
1220mm
250mm min. from either side of appliance
to outer perimeter of enclosure
CEILING
INSIDE
ENCLOSURE
2.4m MIN.
Ceiling inside of the cavity is to be 2.4 metres minimum.
Ceiling in the room is to be 2.4 metres minimum.
Ceiling can be of combustible materials.
Enclosure Width = 1580 mm minimum
Enclosure volume is critical and must not be reduced.
The enclosure must be tted with an air ventilation grill centrally located
below one of the door openings and centrally located above one of the door
openings, as high as possible. Minimum 1080mm above top of fuel loading
door. Both grills must be installed as per diagram below.
Framing
When constructing the framework for the enclosure :
• All framing must be non-combustible material
There must be a 25 mm clearance between any vertical or horizontal stud
and the body of the reduced clearance box, to the sides and above the
reduced clearance box.
Floor Protector
BOTTOM OF VENT
TO BE 50 MM MIN
ABOVE FLOOR PRO-
TECTOR
ABOVE FLOOR
PROTECTOR
300 MM (FROM UNDERSIDE OF
REDUCED CLEARANCE BOX TO
FLOOR PROTECTOR)
10 Manseld L850B ST Woodre
installation
FLUE CLEARANCE TO COMBUSTIBLES
Combustible Enclosure of
Chimney when passing
through 2nd Floor
Combustible Ceiling
2nd Floor
Combustible Ceiling
Minimum
50mm
clearance to
combustibles
as it passes
through floors,
living space
and ceilings.
Minimum
50mm
clearance to
combustibles
as it passes
through floors,
living space
and ceilings.
1. Ventilation grills = 2 grills, 1 below & 1 above fuel loading doors. Grills can be on the same or opposite sides of the enclosure.
Require minimum 8000mm2 of open area for each grill.
2. Require unit to be raised minimum of 300mm from oor protector.
3. Non-combustible board and steel framing is required for the entire enclosure however the ceiling may be of combustible material -
see page 9 for minimum ceiling height.
4. Clearances to combustibles for triple skin ue as it passes through ceiling, living spaces = 50mm.
5. Non-combustible with walls of enclosure to be 9mm thick minimum.
Note: The minimum ue clearance to combustibles
for the triple skin ue as it passes through ceilings,
any enclosure, roof space, etc. is 50 mm.
Manseld L850B ST Woodre 11
installation
OPTIONAL BASE FRAME
CONSTRUCTING YOUR OWN BASE FRAME
WHEN BUILDING YOUR OWN BASE FRAME OR PEDESTAL BASE PLEASE
ENSURE THE FOLLOWING CONDITIONS ARE MET:
1. MINIMUM HEIGHT OF THE BASE FRAME IS 300MM FROM THE FLOOR PROTECTOR TO THE UNDERSIDE OF THE REDUCED CLEARANCE
BOX. IF BASE FRAME DOES NOT SIT ON THE SAME LEVEL OF THE FLOOR PROTECTOR, THEN THE FRAME NEEDS TO BE MADE TALLER
TO ENSURE THE 300MM CLEARANCE IS MET. (SEE PAGE 9).
2. ENSURE THE CENTRE OF THE BASE IS HOLLOW TO ALLOW THE HOOK-UP OF THE OPTIONAL OUTSIDE AIR KIT.
3. ENSURE THE BASE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS
4. ENSURE THE BASE CAN WITHSTAND THE WEIGHT OF AT LEAST 332KG PLUS.
5. ENSURE THE FLOOR BENEATH THE BASE CAN WITHSTAND AT LEAST 332KG PLUS.
6. THE BASE CANNOT BE OF SOLID CONSTRUCTION. COOLING AIR MUST BE ALLOWED TO FLOW UNOBSTRUCTED ACROSS THE BOTTOM
OF THE
REDUCED CLEARANCE BOX.
12 Manseld L850B ST Woodre
installation
FLUE REQUIREMENTS
THE FLUE PIPE SHALL EXTEND NOT LESS THAN 4.6 M ABOVE THE TOP OF THE FLOOR PROTECTOR.
NOTE: INSTALLATION MUST BE CARRIED OUT BY A LICENSED INSTALLER IN ACCORDANCE WITH AS/NZS 2918:2018
6000 3000 3000
6000
3000
3000
3000
3000
3000
6000
Manseld L850B ST Woodre 13
installation
FLUE REQUIREMENTS
Typical Example of a Sloped Ceiling Penetration
Example of Roof Penetration
Gap 50
Gap 50
Gap 50
Gap 50Gap 50
Gap 50
Gap 50
Gap 50
Gap 50Gap 50
50
50
50
5050
roof
175
14 Manseld L850B ST Woodre
installation
INSTALLATION INSTRUCTIONS
UNIT PREPARATION/FRAMING
BEFORE INSTALLING ENSURE THE FOLLOWING:
READ THE ENTIRE MANUAL
EVALUATE THE LOCATION OF YOUR FIREPLACE AND LOCATION
OF OPTIONAL COMPONENTS SUCH AS FAN, OUTSIDE AIR AND
FINISH TRIMS.
DETERMINE THE THICKNESS OF YOUR DESIRED NON-
COMBUSTIBLE FINISHING MATERIALS INCLUDING
THE REQUIRED NON-COMBUSTIBLE BOARD. THIS
PREDETERMINED THICKNESS WILL DICTATE THE ENCLOSURE
DEPTH, POSITION OF THE NAILING STRIPS, FRAMING AND
OVERALL FINAL LOOK OF YOUR FIREPLACE.
The unit comes standard with nailing strips and clean edge frame installed
on both sides. The clean edge frame comes with 20 mm stando brackets on
the top edge plus left & right hand sides (not on bottom) to ensure clearance
to nished wall material.
Clean edge frame: MAXIMUM THICKNESS OF FINISHING MATERIAL:
15MM
1. Determine the location of the replace, ueing location and locations of the
options such as the Fan Kit and outside air.
2. Construct your base frame. Please see BASE FRAME instructions on page
11. The base frame is required TO RAISE THE UNIT in order to meet the
300mm clearance to the oor protector.
3. Install the oor protector (see page on Installation instructions).
4. Frame out side walls only of the replace enclosure. DO NOT FRAME
FRONT OR BACK WALL. All framing for the walls of the enclosure need to
be constructed using steel studs. Please refer to page on clearances for
clearances and enclosure depth.
5. Install the base frame and secure to the oor / oor protector ensuring
the frame is level.
6. Due to the large capacity of the rebox, most homes (especially 'air tight' 5
or 6 Energy Star Rates homes) will require an external air supply to ensure
that the re receives sucient combustion air. If using optional outside
air kit please refer to the outside air kit in this manual. The optional air
kit adapter must be installed prior to the unit being positioned on to the
base frame. Install exible duct from air kit adapter to external air source.
7. Install the replace on the base frame. Secure replace to the base frame
Base Frame
Manseld L850B ST Woodre 15
installation
8. Frame out the front & back walls of the enclosure using steel studs - refer
to pages of this manual for clearances. Leave a 5 mm gap from the side
of the Reduced Clearance Bos to any hiorizontal or vertical steel stud to
allow for expansion.
INSTALLATION INSTRUCTIONS
UNIT PREPARATION/FRAMING
9. You are now ready to install the ueing.
Please refer to Flue requirements in this manual then install your ue system.
10. After the ue has been installed, complete the install of your optional kits
such as fan/heat distribution kit(s) and/or outside air kit.
When cutting a rectangular opening in the nishing
material to t around the clean edge :
Width
The width of the opening must include the actual width of the clean edge
nish (outside edge to outside edge) plus allow for the 20 mm stand-os on
the left & right sides
Height
The height of the opening must include the actual height of the clean edge
nish (outside edge to outside edge) plus allow for the 20 mm stand-os on
the top edge plus a 5 mm air gap along the bottom edge
The actual position of the opening in the facing material will depend on site
conditions, nished oor level, the height of the reduced clearance box o oor
protector level, etc. We suggest, to avoid errors, that these measurements be
taken when the heater is actually installed in its nal location.


Produktspezifikationen

Marke: Regency
Kategorie: Heizung
Modell: Mansfield L850B ST

Brauchst du Hilfe?

Wenn Sie Hilfe mit Regency Mansfield L850B ST benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Regency

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung für -Kategorien-