Radiant TH52Z Bedienungsanleitung
Radiant
Thermometer
TH52Z
Lesen Sie kostenlos die š deutsche Bedienungsanleitung fĆ¼r Radiant TH52Z (5 Seiten) in der Kategorie Thermometer. Dieser Bedienungsanleitung war fĆ¼r 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/5
Before the measurement, please make sure the selected
button accords with the measured position.
TH52Z Multi-function Infrared Thermometer
Functions
Real Time Clock
The real time clock will be recorded with the memory function and help you to recognize each
measurement result. (It includes the 12/24 Format_Hour_Minutes_Date.)
ļ Please see the āReal time clock settingā section to learn how to setup the time in the first use. ļ³
Room Temperature
Suitable ambient temperature is important for the baby and patient, the thermometer always help you
recognize the room temperature.
ļ Setting āReal time clockā first to enable this function. After power off, room temperature will be shown
on the screen with icon.
ļ Please see the āUse of the thermometerā section to learn how to get the correct room temperature.
Forehead / Ear
Temperature
The thermometer has been designed for practical use. Itās not meant to replace a visit to the doctor.
Please also remember to compare the measurement result to your regular body temperature. Please
consult with doctor if you have health concerns.
ļ Please see the āUse of the thermometerā section to learn how to measure the body temperature.
Scan Mode
The Scan mode shows the actual, unadjusted surface temperatures, which is different from the body
temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for
example the babyās milk.
ļ Please see the āUse of the thermometerā section to learn how to measure the object temperature.
Stopwatch The thermometer built the stopwatch function to help you to monitor the heartbeat
since heartbeat is one
of the healthy indexes for people.
ļ Please see the āUse of the Stopwatchā section to learn how to measure the heartbeat result.
Fever Alarm If thermometer detects a body temperature > 37.5Ā°C, there will be a long beep sound followed by three
short beep sound to warn the user for potential fever.
Zone Indicator Under ear or forehead mode, if thermometer detects a body temperature< 37.5Ā°C, there will be " Green"
light signal; if temperature > = 37.5Ā°C and < 38.0Ā°C, there will be" Yellow" light signal; if temperature
> =38.0Ā°C, there will be" Red" light signal.
Memory Locations There are total 9 sets memories for body measurement. Each memory also records the measurement
date/time/mode icon and site location..
ļ When in power on, Press the āON/MEMā button to see the temperature stored with icon.
Ā°C / Ā°F Switch ļ In āpower offā mode (The LCD only shows the date, time and room temperature). Press and hold the
āFOREHEADā button, then immediately press and release the āON/MEMā
button. After 3 seconds, icon
āĀ°Cā will be switched to icon āĀ°Fā. (You may use the same way to switch back to āĀ°Cā)
Real time clock setting
1. Power on: Press the āON/MEMā button. The thermometer is ready for use after hearing two beep sounds.
2. Press and hold the āON/MEMā button for 5sec. When you see the Set icon starts flashing, it indicates that you are in the setting screen.(see the following figure.)
3. Press the āFOREHEADā button to make the ā24ā icon flash. This indicates that you are in the 12/24-hour setting screen. Press the āFOREHEADā button to set
12/24-hour Format from ā24ā(24-hour) to ā12ā(12-hour).
4. Press āON/MEMā button to move the flashing in the sequence shown below to select our settings:
hourļ minutesļ yearļ monthļ dayļ leave the setting screen.
5. While the hour, minutes, year, month, day setting is flashing, use āFOREHEADā button to change it.
Use of the thermometer
1. Always make sure the probe is clean, and without damage.
2. Power on: Press āON/MEMā button.(see figure 1)
3. Mode selection:
3.1 Ear mode :Press the āEarā button, you can get the body temperature by ear measurement after
hearing two beep sounds. (see figure 1)
Specifications ļ¾ Temperature measurement range:
Forehead / Ear mode: 34~42.2Ā°C (93.2~108Ā°F), Scan mode: -22~80Ā°C (-7.6~176Ā°F)
ļ¾ Operating temperature range: 10~40Ā°C (50~104Ā°F)
ļ¾ Storage temperature range: It should be stored at room temperature between -20~+50Ā°C,
RHā¦85%
Transportation temperature shall be less than 70Ā°C, RHā¦95%
ļ¾ Comply with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part
5:Performance of infra-red ear thermometers(with maximum device),
IEC/EN60601-1-2(EMC),IEC/EN60601-1(Safety) standards.
ļ¾ Accuracy:
For ear mode: +/-0.2Ā°C (0.4Ā°F) during 35.5~42Ā°C (95.9~107.6Ā°F),
+/-0.3Ā°C (0.5Ā°F) for other range.
For forehead mode: +/-0.2Ā°C (0.4Ā°F) during 36~39Ā°C (96.8~102Ā°F),
+/-0.3Ā°C (0.5Ā°F) for other range.
For scan mode: +/-0.3Ā°C (0.5Ā°F) during 22~42.2Ā°C (71.6~108Ā°F),
others +/-4% or +/-2Ā°C (4Ā°F) whichever is greater.
ļ¾ Fever alarm & Memory locations under āEar/Forehead modeā (with each measurement
date/time/mode icon)
ļ¾ 3 color LED Fever Indicator
ļ¾ Real time clock, Ā°C / Ā°F Switch mode
ļ¾ Battery: one lithium cell battery (CR2032 *1pcs)
ļ¾ This thermometer converts the ear/forehead temperature to display its āoral equivalent.ā
There is no gender and age limitation for using infrared thermometer.
This is not an AP or APG product.
Figure 1 Figure2 Figure 3 Figure
4
3.2 Forehead mode: Press the āFOREHEADā button, you can get the body temperature by forehead measurement after hearing two beep sounds. (see figure 2)
3.3 Scan Mode: Press and hold the āON/MEMā button, and press the āFOREHEADā button one
time, you can see the icon on your LCD display(see figure 3). In this mode,
press the āFOREHEADā button to get the target surface temperature.
3.4 Stopwatch: Press and hold the āON/MEMā button, and press the āFOREHEADā button twice,
you can see the icon on your LCD display(see figure 4). In this mode, press the
āFOREHEADā button to count by 0.01sec to 3 minutes.
4. Temperature taking:
4.1 Ear temperature measuring, points for attention:
Remarks: a. It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature.
b. To avoid the risk of cross contamination, please clean the probe according to āCare and cleaningā section after each use.
4.1.1 Gently pull the ear back to straighten the ear canal (Fig.4.1.1) and snugly position the probe into the ear canal, aiming towards the
membrane of the eardrum to obtain an accurate reading (Fig.4.1.2).
4.1.2 Press and hold the āEarā button
until you hear a beep sound. Remove the probe from ear and read the temperature measurement
on the LCD.
c. The different temperature varies in healthy persons between different parts of the body can be between 0.2~1Ā°C
d. Clinical repeatability: 0.23Ā°C (<1 year old),0.22Ā°C (1~5 years old),0.21Ā°C (>5 years old)
4.2 Forehead temperature measuring, points for attention:
Remarks: a. Forehead temperature is displayed in oral mode. This mode converts the forehead temperature to display its āoral-equivalentā Value.
b. Before the measurement, please stay in a stable environment for 5mins and avoid exercise, bath for 30mins.
c. Remember to keep the temple area clean and away from sweat, cosmetics and scar while taking temperature.
4.2.1 The temporal artery is connected to the heart via the carotid artery. It is designed to measure the skin surface around
temporal artery, a major artery of the head (Fig.4.2.1).
4.2.2 Attach the thermometer to the required measurement location on the forehead (Fig. 4.2.2). (You can choose left or
right temple.)
4.2.3 Press the āFOREHEAD ā button, and gently scan around the temple area (Fig. 4.2.3). While scanning, you will hear a
beep sound, which indicates you the newest measurement is taking place. Measurement has been completed after
two short beeps are heard and the forehead icon stops flashing. The time consuming for measurement might be
between 5~8 sec (up to 30sec). It depends on how much time the device needs to get the correct forehead
temperature.
4.3 Measuring temperature under Scan mode:
4.3.1 When you press the āFOREHEADā button, you will get the real time temperature immediately. If you press and hold the āFOREHEADā button, the reading of
measurement will be continuous updated.
4.3.2 Applications include temperature measurements for Water, Milk, Cloth, Skin or other object.
* Note: This mode shows the actual, unadjusted surface temperatures, which is different from the body temperature.
4.4 Get the room temperature
4.4.1 Setting āReal time clockā first to enable this function. After power off, room temperature will be shown on the screen with icon.
4.4.2 For room temperature, the thermometer should be placed on the table and avoid the direct sunshine or air conditioner flow on.
4.4.3 The room temperature can be reference after 15min later.
5. After Measurement:
5.1 Power off: Device will automatically shut off if left idle for more than 1 minute to extend battery life. The LCD will only show the date, time and room temperature.
5.2 Clean the probe after each use to ensure an accurate reading and avoid cross contamination. (See the section of Care and Cleaning for details.)
5.3 Remember to put on the Probe Cap when not in use.
Use of the Stopwatch
1. Press and hold the āON/MEMā button, and press the āFOREHEADā button twice for āstopwatchā mode.
2. For start or stop counting, press the āFOREHEADā button; for reset counting, press the āON/MEMā button.
3. Press and hold the āON/MEMā button, and press the āFOREHEADā button to enter the forehead mode.
4. How to measure the heartbeat? If you count out the number of beating is 18 in 15sec, then you can calculate the heartbeat of patient is 72 times in 1min.
Figure 4.1.1 Figure 4.1.2
Figure 4.2.3 Figure 4.2.2 Figure 4.2.1
Ref No.ļ¼022011
Important Notes
Care and cleaning
The probe is the most delicate part of the thermometer. Use with care when cleaning the lens to avoid damage.
a. After the measurement, please use the cotton swab with the Alcohol (70% concentration) to clean the inside of the probe,
including lens and metal parts.
b. Allow the probe to fully dry for at least 1 minute.
c. Storage temperature range: It should be stored at room temperature between -20~+50Ā°C,
RHā¦85%
d .Keep the unit dry and away from any liquids and direct sunlight.
e. The Probe should not be submerged into liquids.
* Note: Please check the device if damaged once it falls. If you canāt make sure of it ,please send the
complete device to the nearest retailer for recalibration.
Holding the thermometer too long may cause a higher ambient temperature reading of the probe.
This could make the body temperature measurement lower than usual.
Battery replacement
ā
1 Open the battery cover: Insert a pointed object, such as a pen, into battery cover pick hole.
At the same time, use thumb to push battery cover out.
ā
2 Hold the device and flip the battery out with a small screwdriver
ā
3 Insert the new battery under the metal hook on the left side and press the right side of the battery
down until you hear a click.
ā
4 Replace the battery cover
Keep the battery away from children. (This device is supplied with one lithium cell (CR2032x1).)
The positive (+) side up and the negative (-) side pointed down.
Trouble shooting:
Error Message Problem Solution
Error 5~9, the system is not functioning properly. Unload the battery, wait for 1 minute and repower it. If the message
reappears, contact the retailer for service.
Measurement before device stabilization. Wait until all the icons stops flashing.
The device showing a rapid ambient temperature change.
The ambient temperature is not within the range between 10oC and 40oC (50oF
~104oF).
Allow the thermometer to rest in a room for at least 30 minutes at room
temperature: 10oC and 40oC (50oF ~104oF).
(1) In Ear/Forehead mode: Temperature taken is higher than +42.2oC (108Ā°F)
(2) In Scan mode: Temperature taken is higher than +80oC (176Ā°F)
(1) In Ear/Forehead mode: Temperature taken is lower than +34oC (93.2Ā°F)
(2) In Scan mode: Temperature taken is lower than ā22oC (-7.6Ā°F)
Please select the target within specifications. If a malfunction still exists,
please contact the nearest retailer.
Device cannot be powered on to the ready stage. Change with a new battery.
Warranty:
Warranty :12 months
Manufacture Dateļ¼as the serial number( please open the battery cover, it is shown on the inside of the device.)
Ex.SN:E912A000001, the first āEā is External, the second number ā9ā is the manufacture year 2009, the third and the fourth number ā12ā is the manufacture month, the
others is the serial number.
Note: Suggest that the device is performed the re-test for accuracy after 3 years. Please send the complete device to the dealers or nearest service address.
However, if this device is used according to the operation instruction, periodic re-calibration is not required.
Please read the instructions for use BF type applied part
Radiant Innovation Inc.
Http://www.radiantek.com.tw
Add: 1F, No.3, Industrial East 9th Road,
Science-Based Industrial Park, HsinChu, Taiwan 300.
Medical Technology Promedt Consulting GmbH
Add: Altenhofstrasse 80, D-66386 St. Ingbert, Germany
Produktspezifikationen
Marke: | Radiant |
Kategorie: | Thermometer |
Modell: | TH52Z |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Radiant TH52Z benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Thermometer Radiant
26 August 2024
Bedienungsanleitung Thermometer
- Thermometer Clatronic
- Thermometer Emerio
- Thermometer Tristar
- Thermometer Hama
- Thermometer Nedis
- Thermometer Philips
- Thermometer SilverCrest
- Thermometer Clas Ohlson
- Thermometer Cotech
- Thermometer Quigg
- Thermometer Voltcraft
- Thermometer Beper
- Thermometer Laserliner
- Thermometer AEG
- Thermometer Arendo
- Thermometer Kitchenware
- Thermometer Melissa
- Thermometer Tefal
- Thermometer Velleman
- Thermometer Alecto
- Thermometer Auriol
- Thermometer Beurer
- Thermometer Bresser
- Thermometer Cresta
- Thermometer Denver
- Thermometer EMOS
- Thermometer Eurochron
- Thermometer Irox
- Thermometer Kƶnig
- Thermometer MarQuant
- Thermometer Medisana
- Thermometer Prologue
- Thermometer Techno Line
- Thermometer Technoline
- Thermometer Telefunken
- Thermometer TFA
- Thermometer Thomson
- Thermometer Trotec
- Thermometer Braun
- Thermometer Cuisinart
- Thermometer Inventum
- Thermometer Pyle
- Thermometer Bartscher
- Thermometer Respekta
- Thermometer Topcom
- Thermometer FlinQ
- Thermometer Motorola
- Thermometer Abus
- Thermometer Elro
- Thermometer Olympia
- Thermometer Livoo
- Thermometer Perel
- Thermometer Geratherm
- Thermometer Kruidvat
- Thermometer ProfiCare
- Thermometer Homedics
- Thermometer Lanaform
- Thermometer Citizen
- Thermometer Aponorm
- Thermometer Boso
- Thermometer Ecomed
- Thermometer Elta
- Thermometer Fysic
- Thermometer Laica
- Thermometer Levita
- Thermometer Microlife
- Thermometer Omron
- Thermometer Rossmax
- Thermometer Sanitas
- Thermometer Terraillon
- Thermometer Veroval
- Thermometer Sencor
- Thermometer Amprobe
- Thermometer Leifheit
- Thermometer Beaba
- Thermometer Dittmann
- Thermometer Domotherm
- Thermometer Hartig And Helling
- Thermometer IHealth
- Thermometer Miniland
- Thermometer Reer
- Thermometer Scala
- Thermometer Thermoval
- Thermometer Vicks
- Thermometer Waeco
- Thermometer BabyOno
- Thermometer Luvion
- Thermometer Westfalia
- Thermometer Honeywell
- Thermometer Fora
- Thermometer Globaltronics
- Thermometer Hartmann
- Thermometer Silverline
- Thermometer Kerbl
- Thermometer Medel
- Thermometer Easypix
- Thermometer Zeiss
- Thermometer BeSafe
- Thermometer Safety 1st
- Thermometer Inkbird
- Thermometer Kyoritsu
- Thermometer Milwaukee
- Thermometer Testo
- Thermometer Omega
- Thermometer Esperanza
- Thermometer Innoliving
- Thermometer TrueLife
- Thermometer Salter
- Thermometer SereneLife
- Thermometer Gima
- Thermometer Testboy
- Thermometer Extech
- Thermometer Weber
- Thermometer Fluke
- Thermometer FLIR
- Thermometer Orbegozo
- Thermometer Vemer
- Thermometer La Crosse Technology
- Thermometer Oregon Scientific
- Thermometer Duronic
- Thermometer EasyLife
- Thermometer Eks
- Thermometer Elem6
- Thermometer Emga
- Thermometer Global Tronics
- Thermometer Guide
- Thermometer Joy-it
- Thermometer Jumper
- Thermometer Knikker
- Thermometer La Crosse
- Thermometer MostEssential
- Thermometer Okoia
- Thermometer Pacom
- Thermometer Pasha
- Thermometer PCE Instruments
- Thermometer Premiumful
- Thermometer Salva Tec
- Thermometer Save Demp
- Thermometer Sensitec
- Thermometer Silvergear
- Thermometer Taylor
- Thermometer TQC
- Thermometer Turbotech
- Thermometer Turbotronic
- Thermometer Uebe
- Thermometer Uni-T
- Thermometer VDH
- Thermometer WBTT
- Thermometer Welby
- Thermometer Welch Allyn
- Thermometer Mabis
- Thermometer TFA Dostmann
- Thermometer Owon
- Thermometer PeakTech
- Thermometer ZKTeco
- Thermometer Comark
- Thermometer Speco Technologies
- Thermometer AcuRite
- Thermometer InfiRay
- Thermometer Beha-Amprobe
- Thermometer Chauvin Arnoux
- Thermometer Pancontrol
- Thermometer Ebro
- Thermometer Etekcity
- Thermometer Greisinger
- Thermometer Mobi
- Thermometer Grado
- Thermometer Klein Tools
- Thermometer Delta Ohm
- Thermometer TensCare
- Thermometer A&D
- Thermometer ClimeMET
- Thermometer AvaTemp
- Thermometer AnD
- Thermometer ATN
- Thermometer Bioland
- Thermometer Blue Circle Medical
- Thermometer CDN
- Thermometer Telesystem
- Thermometer Bintoi
- Thermometer Innovo
- Thermometer Yummly
- Thermometer Aspen
- Thermometer Bearware
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
13 Oktober 2024
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
7 Oktober 2024
5 Oktober 2024
4 Oktober 2024