Radiant TH52Z Bedienungsanleitung


Lesen Sie kostenlos die šŸ“– deutsche Bedienungsanleitung fĆ¼r Radiant TH52Z (5 Seiten) in der Kategorie Thermometer. Dieser Bedienungsanleitung war fĆ¼r 16 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/5
Before the measurement, please make sure the selected
button accords with the measured position.
TH52Z Multi-function Infrared Thermometer
Functions
Real Time Clock
The real time clock will be recorded with the memory function and help you to recognize each
measurement result. (It includes the 12/24 Format_Hour_Minutes_Date.)
ļƒ  Please see the ā€œReal time clock settingā€ section to learn how to setup the time in the first use. ļƒ³
Room Temperature
Suitable ambient temperature is important for the baby and patient, the thermometer always help you
recognize the room temperature.
ļƒ  Setting ā€œReal time clockā€ first to enable this function. After power off, room temperature will be shown
on the screen with icon.
ļƒ  Please see the ā€œUse of the thermometerā€ section to learn how to get the correct room temperature.
Forehead / Ear
Temperature
The thermometer has been designed for practical use. Itā€™s not meant to replace a visit to the doctor.
Please also remember to compare the measurement result to your regular body temperature. Please
consult with doctor if you have health concerns.
ļƒ  Please see the ā€œUse of the thermometerā€ section to learn how to measure the body temperature.
Scan Mode
The Scan mode shows the actual, unadjusted surface temperatures, which is different from the body
temperature. It can help you to monitor if the object temperature is suitable for the baby or patient, for
example the babyā€™s milk.
ļƒ  Please see the ā€œUse of the thermometerā€ section to learn how to measure the object temperature.
Stopwatch The thermometer built the stopwatch function to help you to monitor the heartbeat
since heartbeat is one
of the healthy indexes for people.
ļƒ  Please see the ā€œUse of the Stopwatchā€ section to learn how to measure the heartbeat result.
Fever Alarm If thermometer detects a body temperature > 37.5Ā°C, there will be a long beep sound followed by three
short beep sound to warn the user for potential fever.
Zone Indicator Under ear or forehead mode, if thermometer detects a body temperature< 37.5Ā°C, there will be " Green"
light signal; if temperature > = 37.5Ā°C and < 38.0Ā°C, there will be" Yellow" light signal; if temperature
> =38.0Ā°C, there will be" Red" light signal.
Memory Locations There are total 9 sets memories for body measurement. Each memory also records the measurement
date/time/mode icon and site location..
ļƒ  When in power on, Press the ā€œON/MEMā€ button to see the temperature stored with icon.
Ā°C / Ā°F Switch ļƒ  In ā€œpower offā€ mode (The LCD only shows the date, time and room temperature). Press and hold the
ā€œFOREHEADā€ button, then immediately press and release the ā€œON/MEMā€
button. After 3 seconds, icon
ā€œĀ°Cā€ will be switched to icon ā€œĀ°Fā€. (You may use the same way to switch back to ā€œĀ°Cā€)
Real time clock setting
1. Power on: Press the ā€œON/MEMā€ button. The thermometer is ready for use after hearing two beep sounds.
2. Press and hold the ā€œON/MEMā€ button for 5sec. When you see the Set icon starts flashing, it indicates that you are in the setting screen.(see the following figure.)
3. Press the ā€œFOREHEADā€ button to make the ā€œ24ā€ icon flash. This indicates that you are in the 12/24-hour setting screen. Press the ā€œFOREHEADā€ button to set
12/24-hour Format from ā€œ24ā€(24-hour) to ā€œ12ā€(12-hour).
4. Press ā€œON/MEMā€ button to move the flashing in the sequence shown below to select our settings:
hourļƒ minutesļƒ yearļƒ monthļƒ dayļƒ leave the setting screen.
5. While the hour, minutes, year, month, day setting is flashing, use ā€œFOREHEADā€ button to change it.
Use of the thermometer
1. Always make sure the probe is clean, and without damage.
2. Power on: Press ā€œON/MEMā€ button.(see figure 1)
3. Mode selection:
3.1 Ear mode :Press the ā€œEarā€ button, you can get the body temperature by ear measurement after
hearing two beep sounds. (see figure 1)
Specifications ļƒ¾ Temperature measurement range:
Forehead / Ear mode: 34~42.2Ā°C (93.2~108Ā°F), Scan mode: -22~80Ā°C (-7.6~176Ā°F)
ļƒ¾ Operating temperature range: 10~40Ā°C (50~104Ā°F)
ļƒ¾ Storage temperature range: It should be stored at room temperature between -20~+50Ā°C,
RHā‰¦85%
Transportation temperature shall be less than 70Ā°C, RHā‰¦95%
ļƒ¾ Comply with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part
5:Performance of infra-red ear thermometers(with maximum device),
IEC/EN60601-1-2(EMC),IEC/EN60601-1(Safety) standards.
ļƒ¾ Accuracy:
For ear mode: +/-0.2Ā°C (0.4Ā°F) during 35.5~42Ā°C (95.9~107.6Ā°F),
+/-0.3Ā°C (0.5Ā°F) for other range.
For forehead mode: +/-0.2Ā°C (0.4Ā°F) during 36~39Ā°C (96.8~102Ā°F),
+/-0.3Ā°C (0.5Ā°F) for other range.
For scan mode: +/-0.3Ā°C (0.5Ā°F) during 22~42.2Ā°C (71.6~108Ā°F),
others +/-4% or +/-2Ā°C (4Ā°F) whichever is greater.
ļƒ¾ Fever alarm & Memory locations under ā€œEar/Forehead modeā€ (with each measurement
date/time/mode icon)
ļƒ¾ 3 color LED Fever Indicator
ļƒ¾ Real time clock, Ā°C / Ā°F Switch mode
ļƒ¾ Battery: one lithium cell battery (CR2032 *1pcs)
ļƒ¾ This thermometer converts the ear/forehead temperature to display its ā€œoral equivalent.ā€
There is no gender and age limitation for using infrared thermometer.
This is not an AP or APG product.
Figure 1 Figure2 Figure 3 Figure
4
3.2 Forehead mode: Press the ā€œFOREHEADā€ button, you can get the body temperature by forehead measurement after hearing two beep sounds. (see figure 2)
3.3 Scan Mode: Press and hold the ā€œON/MEMā€ button, and press the ā€œFOREHEADā€ button one
time, you can see the icon on your LCD display(see figure 3). In this mode,
press the ā€œFOREHEADā€ button to get the target surface temperature.
3.4 Stopwatch: Press and hold the ā€œON/MEMā€ button, and press the ā€œFOREHEADā€ button twice,
you can see the icon on your LCD display(see figure 4). In this mode, press the
ā€œFOREHEADā€ button to count by 0.01sec to 3 minutes.
4. Temperature taking:
4.1 Ear temperature measuring, points for attention:
Remarks: a. It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature.
b. To avoid the risk of cross contamination, please clean the probe according to ā€œCare and cleaningā€ section after each use.
4.1.1 Gently pull the ear back to straighten the ear canal (Fig.4.1.1) and snugly position the probe into the ear canal, aiming towards the
membrane of the eardrum to obtain an accurate reading (Fig.4.1.2).
4.1.2 Press and hold the ā€œEarā€ button
until you hear a beep sound. Remove the probe from ear and read the temperature measurement
on the LCD.
c. The different temperature varies in healthy persons between different parts of the body can be between 0.2~1Ā°C
d. Clinical repeatability: 0.23Ā°C (<1 year old),0.22Ā°C (1~5 years old),0.21Ā°C (>5 years old)
4.2 Forehead temperature measuring, points for attention:
Remarks: a. Forehead temperature is displayed in oral mode. This mode converts the forehead temperature to display its ā€œoral-equivalentā€ Value.
b. Before the measurement, please stay in a stable environment for 5mins and avoid exercise, bath for 30mins.
c. Remember to keep the temple area clean and away from sweat, cosmetics and scar while taking temperature.
4.2.1 The temporal artery is connected to the heart via the carotid artery. It is designed to measure the skin surface around
temporal artery, a major artery of the head (Fig.4.2.1).
4.2.2 Attach the thermometer to the required measurement location on the forehead (Fig. 4.2.2). (You can choose left or
right temple.)
4.2.3 Press the ā€œFOREHEAD ā€ button, and gently scan around the temple area (Fig. 4.2.3). While scanning, you will hear a
beep sound, which indicates you the newest measurement is taking place. Measurement has been completed after
two short beeps are heard and the forehead icon stops flashing. The time consuming for measurement might be
between 5~8 sec (up to 30sec). It depends on how much time the device needs to get the correct forehead
temperature.
4.3 Measuring temperature under Scan mode:
4.3.1 When you press the ā€œFOREHEADā€ button, you will get the real time temperature immediately. If you press and hold the ā€œFOREHEADā€ button, the reading of
measurement will be continuous updated.
4.3.2 Applications include temperature measurements for Water, Milk, Cloth, Skin or other object.
* Note: This mode shows the actual, unadjusted surface temperatures, which is different from the body temperature.
4.4 Get the room temperature
4.4.1 Setting ā€œReal time clockā€ first to enable this function. After power off, room temperature will be shown on the screen with icon.
4.4.2 For room temperature, the thermometer should be placed on the table and avoid the direct sunshine or air conditioner flow on.
4.4.3 The room temperature can be reference after 15min later.
5. After Measurement:
5.1 Power off: Device will automatically shut off if left idle for more than 1 minute to extend battery life. The LCD will only show the date, time and room temperature.
5.2 Clean the probe after each use to ensure an accurate reading and avoid cross contamination. (See the section of Care and Cleaning for details.)
5.3 Remember to put on the Probe Cap when not in use.
Use of the Stopwatch
1. Press and hold the ā€œON/MEMā€ button, and press the ā€œFOREHEADā€ button twice for ā€œstopwatchā€ mode.
2. For start or stop counting, press the ā€œFOREHEADā€ button; for reset counting, press the ā€œON/MEMā€ button.
3. Press and hold the ā€œON/MEMā€ button, and press the ā€œFOREHEADā€ button to enter the forehead mode.
4. How to measure the heartbeat? If you count out the number of beating is 18 in 15sec, then you can calculate the heartbeat of patient is 72 times in 1min.
Figure 4.1.1 Figure 4.1.2
Figure 4.2.3 Figure 4.2.2 Figure 4.2.1
Ref No.ļ¼š022011
Important Notes
Care and cleaning
The probe is the most delicate part of the thermometer. Use with care when cleaning the lens to avoid damage.
a. After the measurement, please use the cotton swab with the Alcohol (70% concentration) to clean the inside of the probe,
including lens and metal parts.
b. Allow the probe to fully dry for at least 1 minute.
c. Storage temperature range: It should be stored at room temperature between -20~+50Ā°C,
RHā‰¦85%
d .Keep the unit dry and away from any liquids and direct sunlight.
e. The Probe should not be submerged into liquids.
* Note: Please check the device if damaged once it falls. If you canā€™t make sure of it ,please send the
complete device to the nearest retailer for recalibration.
Holding the thermometer too long may cause a higher ambient temperature reading of the probe.
This could make the body temperature measurement lower than usual.
Battery replacement
ā—‹
1 Open the battery cover: Insert a pointed object, such as a pen, into battery cover pick hole.
At the same time, use thumb to push battery cover out.
ā—‹
2 Hold the device and flip the battery out with a small screwdriver
ā—‹
3 Insert the new battery under the metal hook on the left side and press the right side of the battery
down until you hear a click.
ā—‹
4 Replace the battery cover
Keep the battery away from children. (This device is supplied with one lithium cell (CR2032x1).)
The positive (+) side up and the negative (-) side pointed down.
Trouble shooting:
Error Message Problem Solution
Error 5~9, the system is not functioning properly. Unload the battery, wait for 1 minute and repower it. If the message
reappears, contact the retailer for service.
Measurement before device stabilization. Wait until all the icons stops flashing.
The device showing a rapid ambient temperature change.
The ambient temperature is not within the range between 10oC and 40oC (50oF
~104oF).
Allow the thermometer to rest in a room for at least 30 minutes at room
temperature: 10oC and 40oC (50oF ~104oF).
(1) In Ear/Forehead mode: Temperature taken is higher than +42.2oC (108Ā°F)
(2) In Scan mode: Temperature taken is higher than +80oC (176Ā°F)
(1) In Ear/Forehead mode: Temperature taken is lower than +34oC (93.2Ā°F)
(2) In Scan mode: Temperature taken is lower than ā€“22oC (-7.6Ā°F)
Please select the target within specifications. If a malfunction still exists,
please contact the nearest retailer.
Device cannot be powered on to the ready stage. Change with a new battery.
Warranty:
Warranty :12 months
Manufacture Dateļ¼šas the serial number( please open the battery cover, it is shown on the inside of the device.)
Ex.SN:E912A000001, the first ā€œEā€ is External, the second number ā€œ9ā€ is the manufacture year 2009, the third and the fourth number ā€œ12ā€ is the manufacture month, the
others is the serial number.
Note: Suggest that the device is performed the re-test for accuracy after 3 years. Please send the complete device to the dealers or nearest service address.
However, if this device is used according to the operation instruction, periodic re-calibration is not required.
Please read the instructions for use BF type applied part
Radiant Innovation Inc.
Http://www.radiantek.com.tw
Add: 1F, No.3, Industrial East 9th Road,
Science-Based Industrial Park, HsinChu, Taiwan 300.
Medical Technology Promedt Consulting GmbH
Add: Altenhofstrasse 80, D-66386 St. Ingbert, Germany


Produktspezifikationen

Marke: Radiant
Kategorie: Thermometer
Modell: TH52Z

Brauchst du Hilfe?

Wenn Sie Hilfe mit Radiant TH52Z benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Thermometer Radiant

Bedienungsanleitung Thermometer

Neueste Bedienungsanleitung fĆ¼r -Kategorien-