Prem-i-air EH0522 Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Prem-i-air EH0522 (8 Seiten) in der Kategorie Ventilator. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
EH0522
18" Air Circulator
3 Speed settings
Full tilt adjustment
Page 1
IMPORTANT
Installer and Users please note:
These instructions should be read carefully and left with the user of the
product for future reference.
OPERATION
• Plug the mains lead into a 13 Amp mains socket.
• If connecting via an extension lead, make sure that the lead is rated at 6
Amps or more, and that it is fully unwound
• Tilt the fan to the required angle
• Switch the appliance on at the mains socket.
• Turn the rotary switch to the speed required:
Low Speed = 2700 m3/h airflow
Medium Speed = 3000 m3/h airflow
High Speed = 3660 m3/h airflow
• It is normal for the motor to become warm in normal use.
• Unplug the appliance from the mains when not in use.
PRODUCT SAFETY
• This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved.
• Children shall not play with the appliance.
• Cleaning and user maintenance shall not be made by children without
supervision.
• Do not use in close proximity to gas appliances
• For indoor use only.
• Do not cover when in use.
• Do not place the mains lead beneath a carpet or rug.
• Do not use the appliance in locations where paint, petrol or other
flammable liquids are used or stored.
• Do no insert any object into the appliance through the grilles. This may
damage the appliance or result in overheating or electric shock.
• Do not use this appliance in the immediate surroundings of a bath, a
shower or a swimming pool.
• The appliance is fitted with an overload cut-out which will operate if the
motor overheats or is stalled. If this happens, disconnect from the mains
supply immediately, and allow the motor to cool down.
Page 2
PAT TESTING
When used in an office environment, this product must be safety-tested
yearly by a qualified electrician (PAT Tested) in order to comply with the
Electricity at Work Regulations.
If hired out, it must be PAT tested prior to each hire.
We recommend that it is PAT tested regularly when used in a domestic
environment.
GENERAL SAFETY REQUIREMENTS
Domestic wiring must be tested periodically by a qualified electrician at
least once every 10 years or at every change of occupancy.
For office and retail premises, and buildings such as village halls, the
wiring must be inspected at least once every 5 years.
It is recommended that all building be fitted with smoke alarms (it is
mandatory for new buildings).
OPERATING COSTS
At time of going to press, the average cost of electricity is 12p per unit
(kilowatt-hour). The amount you are being charged will be shown on your
electricity bill. At this cost, the fan will cost 29p per day to run on the "low
speed" setting, 31p per day on the "medium speed" setting or 37p per
day to run on the "high speed" setting.
MAINTENANCE
Before cleaning, turn the appliance off, and disconnect from the mains
supply. The appliance may then be cleaned using a damp cloth with a
drop of washing-up liquid to remove any dust or dirt from the case. Do no
use stronger detergents or solvents as these may damage the paint
finish.
Using a dry 1" (25mm) paint-brush, remove any dust from the grilles.
If the mains lead is d amaged, it must be replaced by the manufacturer or
and authorised service centre.
If the mains plug needs to be replaced, proceed as
follows:
• Connect the brown wire to the terminal labelled "L".
• Connect the blue wire to the terminal labelled "N".
• Connect the green/yellow wire to the terminal
labelled with the earth symbol or "E".
• Make sure that the cord-grip is positioned correctly
(over the outer sheath of the cable) and it fully tightened.
Fuse
(3A)
Earth
(Green
Yellow)
Neutral
(Blue)
Live
(Brown)
• If the plug is fitted with a 13 A fuse, replace it by a 3 A fuse.
Page 3


Produktspezifikationen

Marke: Prem-i-air
Kategorie: Ventilator
Modell: EH0522

Brauchst du Hilfe?

Wenn Sie Hilfe mit Prem-i-air EH0522 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Ventilator Prem-i-air

Bedienungsanleitung Ventilator

Neueste Bedienungsanleitung für -Kategorien-