Powerplus POWXG9554 Bedienungsanleitung
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Powerplus POWXG9554 (5 Seiten) in der Kategorie pomp. Dieser Bedienungsanleitung war für 18 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/5
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 SPECIFIC SAFETY WARNINGS ..................................................... 3
6 ASSEMBLY ...................................................................................... 3
6.1 Electrical connection .............................................................................................. 3
6.2 Earth ........................................................................................................................ 3
7 OPERATION ..................................................................................... 3
7.1 Pressure hose ......................................................................................................... 4
7.2 Safety requirements ................................................................................................ 4
8 CLEANING AND MAINTENANCE ................................................... 5
8.1 Cleaning 5 ...................................................................................................................
9 TECHNICAL DATA .......................................................................... 5
10 NOISE ............................................................................................... 5
11 TROUBLE SHOOTING .................................................................... 5
12 WARRANTY ..................................................................................... 7
13 ENVIRONMENT ............................................................................... 7
14 DECLARATION OF CONFORMITY ................................................ 8
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 3www.varo.com
5 SPECIFIC SAFETY WARNINGS
▪ This water pump has no water-sprinkling protection feature and should be placed only in a
dry environment. Never place the water pump or operate it in the rain or in a humid space.
▪ This water pump should not be used with flammable or harmful liquids.
▪ Idle operation of the water pump must be avoided.
▪ This water pump is for work in clean water. The scope its application includes irrigation of
in the garden, water supply to a household, sprinkling in a garden or on farmland.
▪ This water pump may not be exposed for long periods to impurities, sand, stone, sticky
substances, etc., mixed in with the conveyed media. Because the conveyed media may
contain chemical corrosive substances, it is necessary to pay special attention to
preventing influence by these on the material of the pump body. It is not permitted to use
this water pump to convey drinking water.
This appliance cannot be used by children or people who are physically,
mentally or developmentally impaired, or people who lack experience or
knowledge, except in case these people receive instruction from a person
responsible for their safety, a supervisor, or by studying the preceding
instructions concerning use of this appliance.
6 ASSEMBLY
▪ During the installation of the water pump, the power supply to the water pump must be
switched off.
▪ During installation of the equipment, it is necessary to keep it under dry and well-ventilated
conditions, at an ambient temperature below 40°C.
▪ If the required pumping water is excessive due to your own action, resulting in flooding of
the irrigation site, a number of protective measures may be taken (e.g. installation of a
device for discharging the excess water, an alarm, standby pump, water container, etc.).
However, our company is not responsible for any losses thus caused.
▪ Before use, the water pump should be inspected for safety to ensure that there is no
damage to the power cable or the plug.
6.1 Electrical connection
▪ The electrician responsible for installation must check to ensure that the electrical
connection is in accordance with the standard, including the earth terminal.
▪ It is necessary to check the rated current of the electric contact with protective switch - this
must be 30mA.
6.2 Earth
The water pump must be well earthed. Short-circuiting will render the relevant articles of the
guarantee invalid. If it is necessary to increase the length of the original cable, a cable with the
same section as the original cable must be used.
7 OPERATION
The pumps are not self-priming pumps. This means that the suction hose should first of all be
fitted with:
1 Non-return valve with filter; this ensures that, after disconnecting the pump, the hose
and the pump do not run dry. This part of the hose is suspended in the water to be
pumped away.
2 Hose with coupling nut; this end of the hose is attached to the front of the pump.
3 Both accessories should be securely screwed on to the hose using a hose clip.
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 5www.varo.com
8 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
8.1 Cleaning
Under normal conditions, the water pump is free of maintenance. However, the pump should
not be placed in the open air during rain, in a humid place, or dirty or frozen environment.
▪ Freezing, idling or blocking by impurities should be avoided.
▪ Always disconnect the power supply before maintenance of the pump.
▪ If the power cable is damaged, it must be replaced by professional personnel. Damage
caused by short circuiting is not included in scope of the guarantee.
▪ If trouble with the pump is experienced, guaranteed repairs must be carried out by an
authorized maintenance center.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
9 TECHNICAL DATA
type
POWXG9554
Mains voltage / frequency
230V~ /50Hz
Rated power
1000W
Max. pump capacity
3500 l/hour
Max. lift
44 m
Maximum suction level
7 m
Max. water temperature
35°C
Min. diameter of suction hose
1” (25mm)
Min. diameter of pressure hose
3/ 204” ( mm)
Cable length
1,2 m
10 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
72 dB(A)
Acoustic power level LwA
86 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
11 TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
The electric motor is
running but the pump
does not suck water
After the pump
starts, the pump
body does not fill
with water
Fill the pump with water
Produktspezifikationen
Marke: | Powerplus |
Kategorie: | pomp |
Modell: | POWXG9554 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Powerplus POWXG9554 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung pomp Powerplus
7 Oktober 2024
11 August 2024
7 August 2024
4 August 2024
1 August 2024
30 Juli 2024
30 Juli 2024
28 Juli 2024
27 Juli 2024
26 Juli 2024
Bedienungsanleitung pomp
- pomp Crivit
- pomp SilverCrest
- pomp SKS
- pomp Makita
- pomp Vonroc
- pomp Siemens
- pomp Powerfix
- pomp Black And Decker
- pomp Ryobi
- pomp Coleman
- pomp Einhell
- pomp Worx
- pomp Bartscher
- pomp Ultimate Speed
- pomp Eheim
- pomp Eurom
- pomp Hyundai
- pomp Fuxtec
- pomp Hazet
- pomp Metabo
- pomp Kärcher
- pomp Güde
- pomp Scheppach
- pomp Fieldmann
- pomp Wetelux
- pomp Westfalia
- pomp Vaillant
- pomp Husqvarna
- pomp Enermax
- pomp MSW
- pomp Germania
- pomp Fluval
- pomp Vetus
- pomp Jabsco
- pomp Sanibroyeur
- pomp Topeak
- pomp Hayward
- pomp Gre
- pomp Milwaukee
- pomp Toolcraft
- pomp Osram
- pomp Bestway
- pomp AL-KO
- pomp Gardena
- pomp Melinera
- pomp Blackburn
- pomp Lezyne
- pomp Alpha Tools
- pomp Sicce
- pomp Bulex
- pomp Danfoss
- pomp Comet
- pomp Hozelock
- pomp Ozito
- pomp Blumfeldt
- pomp Nibe
- pomp Sun Joe
- pomp Fluke
- pomp Nefit
- pomp Oase
- pomp POLARIS
- pomp Velda
- pomp Vivaria
- pomp Waldbeck
- pomp WHALE
- pomp AstralPool
- pomp Pedrollo
- pomp Esotec
- pomp T.I.P.
- pomp Panduit
- pomp Heissner
- pomp DAB
- pomp Abac
- pomp Baracuda
- pomp Ubbink
- pomp JANDY
- pomp Liberty Pumps
- pomp Monzana
- pomp Lifan
- pomp Elpumps
- pomp For_Q
- pomp Simpson
- pomp Pontec
- pomp BluGarda
- pomp Grundfos
- pomp Zoeller
- pomp B-Air
- pomp Anova
- pomp Perlick
- pomp Fiap
- pomp Little Giant
- pomp Ebara
- pomp Basement Watchdog
- pomp Barwig
- pomp Wayne
- pomp Ribimex
- pomp Maruyama
- pomp ESPA
- pomp Hollex
- pomp Sauermann
- pomp Eco-Flo
- pomp Nowax
- pomp EvoHeat
- pomp Zéfal
- pomp OSIP
- pomp Franklin Electric
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
13 Oktober 2024
2 Oktober 2024
1 Oktober 2024
1 Oktober 2024