Powerplus POWXG9554 Bedienungsanleitung

Powerplus pomp POWXG9554

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Powerplus POWXG9554 (5 Seiten) in der Kategorie pomp. Dieser Bedienungsanleitung war für 18 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/5
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 SPECIFIC SAFETY WARNINGS ..................................................... 3
6 ASSEMBLY ...................................................................................... 3
6.1 Electrical connection .............................................................................................. 3
6.2 Earth ........................................................................................................................ 3
7 OPERATION ..................................................................................... 3
7.1 Pressure hose ......................................................................................................... 4
7.2 Safety requirements ................................................................................................ 4
8 CLEANING AND MAINTENANCE ................................................... 5
8.1 Cleaning 5 ...................................................................................................................
9 TECHNICAL DATA .......................................................................... 5
10 NOISE ............................................................................................... 5
11 TROUBLE SHOOTING .................................................................... 5
12 WARRANTY ..................................................................................... 7
13 ENVIRONMENT ............................................................................... 7
14 DECLARATION OF CONFORMITY ................................................ 8
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 3www.varo.com
5 SPECIFIC SAFETY WARNINGS
This water pump has no water-sprinkling protection feature and should be placed only in a
dry environment. Never place the water pump or operate it in the rain or in a humid space.
This water pump should not be used with flammable or harmful liquids.
Idle operation of the water pump must be avoided.
This water pump is for work in clean water. The scope its application includes irrigation of
in the garden, water supply to a household, sprinkling in a garden or on farmland.
This water pump may not be exposed for long periods to impurities, sand, stone, sticky
substances, etc., mixed in with the conveyed media. Because the conveyed media may
contain chemical corrosive substances, it is necessary to pay special attention to
preventing influence by these on the material of the pump body. It is not permitted to use
this water pump to convey drinking water.
This appliance cannot be used by children or people who are physically,
mentally or developmentally impaired, or people who lack experience or
knowledge, except in case these people receive instruction from a person
responsible for their safety, a supervisor, or by studying the preceding
instructions concerning use of this appliance.
6 ASSEMBLY
During the installation of the water pump, the power supply to the water pump must be
switched off.
During installation of the equipment, it is necessary to keep it under dry and well-ventilated
conditions, at an ambient temperature below 40°C.
If the required pumping water is excessive due to your own action, resulting in flooding of
the irrigation site, a number of protective measures may be taken (e.g. installation of a
device for discharging the excess water, an alarm, standby pump, water container, etc.).
However, our company is not responsible for any losses thus caused.
Before use, the water pump should be inspected for safety to ensure that there is no
damage to the power cable or the plug.
6.1 Electrical connection
The electrician responsible for installation must check to ensure that the electrical
connection is in accordance with the standard, including the earth terminal.
It is necessary to check the rated current of the electric contact with protective switch - this
must be 30mA.
6.2 Earth
The water pump must be well earthed. Short-circuiting will render the relevant articles of the
guarantee invalid. If it is necessary to increase the length of the original cable, a cable with the
same section as the original cable must be used.
7 OPERATION
The pumps are not self-priming pumps. This means that the suction hose should first of all be
fitted with:
1 Non-return valve with filter; this ensures that, after disconnecting the pump, the hose
and the pump do not run dry. This part of the hose is suspended in the water to be
pumped away.
2 Hose with coupling nut; this end of the hose is attached to the front of the pump.
3 Both accessories should be securely screwed on to the hose using a hose clip.
POWXG9554 EN
Copyright © VARO NV 2020 P a g e | 5www.varo.com
8 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
8.1 Cleaning
Under normal conditions, the water pump is free of maintenance. However, the pump should
not be placed in the open air during rain, in a humid place, or dirty or frozen environment.
Freezing, idling or blocking by impurities should be avoided.
Always disconnect the power supply before maintenance of the pump.
If the power cable is damaged, it must be replaced by professional personnel. Damage
caused by short circuiting is not included in scope of the guarantee.
If trouble with the pump is experienced, guaranteed repairs must be carried out by an
authorized maintenance center.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
9 TECHNICAL DATA
type
POWXG9554
Mains voltage / frequency
230V~ /50Hz
Rated power
1000W
Max. pump capacity
3500 l/hour
Max. lift
44 m
Maximum suction level
7 m
Max. water temperature
35°C
Min. diameter of suction hose
1” (25mm)
Min. diameter of pressure hose
3/ 204” ( mm)
Cable length
1,2 m
10 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
72 dB(A)
Acoustic power level LwA
86 dB(A)
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
11 TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSE
The electric motor is
running but the pump
does not suck water
After the pump
starts, the pump
body does not fill
with water