Planet PWR-75-24 Bedienungsanleitung
Planet
Computeradapter
PWR-75-24
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Planet PWR-75-24 (2 Seiten) in der Kategorie Computeradapter. Dieser Bedienungsanleitung war für 17 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/2
- 1 - - 2 - - 3 - - 4 -
DC Single Output Industrial
DIN Rail Power Supply
PWR-40-24 / PWR-60-24
PWR-75-24 / PWR-120-48
PWR-240-48 / PWR-480-48
User's Manual
1. Package Contents
Thanks for purchasing DC Single Output Industrial DIN Rail
Power Supply units from PLANET technology; the DC Single
Output Industrial DIN Rail Power Supply units can transform AC
power into DC power output for PLANET Industrial equipment.
The following models come with the DC Single Output Industrial
DIN Rail Power Supply units:
PWR-40-24 (MEAN WELL / MDR-40-24): l 40W 24V DC
Single Output Industrial DIN Rail Power Supply
(-20 ~ 70 degrees C)
PWR-60-24 l 60W 24V DC (MEAN WELL / MDR-60-24):
Single Output Industrial DIN Rail Power Supply
(-20 ~ 70 degrees C)
PWR-75-24 (MEAN WELL / DR-75-24): l 75W 24V DC
Single Output Industrial DIN Rail Power Supply
(-10 ~ 60 degrees C)
PWR-120-48 (MEAN WELL / DR-120-48): l 120W 48V DC
Single Output Industrial DIN Rail Power Supply
(-10 ~ 60 degrees C)
PWR-240-48 (MEAN WELL / DR-240-48): l 240W 48V DC
2. Requirements
The DC Single Output Industrial DIN Rail Power Supply units
are designed for providing DC power to PLANET Industrial
equipment. For AC power input and DC power output from
DC Single Output Industrial DIN Rail Power Supply units, the
following equipment is necessary for further installation.
AC Power Cord Cable x 1 l
Terminal Block Connector within Two DC Power Inputs Wires l
Cutting Tools: Long Nose Pliers and Pen Knife l
Note
1. Before working on the device, please make
sure power cord has been unplugged from
power outlet.
2. PLANET DIN-Rail power supply series is for
indoor only.
3. PLANET DIN-Rail power supply series must
be earthed.
3. AC Power Cord Cable Installation
The DC Single Output Industrial DIN Rail Power Supply unit
power requirement is 100-240V AC, 50/60Hz with power input
lines. Suggest use standard AC Power Cord Cable.
Step 1: Use pen knife to cut open the AC Power Cord Cable.
Step 2: Open the AC Power Cord Cable and there are 3 lines
inside.
Step 4: Make sure the lines are not disorderly and confused.
Step 5: Please verify the 3 lines, which are live line, null line
and earth line.
Note
The standard AC power cord, live line is black,
null line is white and earth line is green. Please
verify these 3 lines from your AC power cord
before starting the following procedures.
Live line Black color
Null line White color
Earth line Green color
Wiring the AC Power Input:
: Earth line.
: Null line.
: Live line.
Note
1. Please do not connect the power plug of the
power cable to a standard wall outlet during
this installation.
2. The example is based on PWR-40-24 for
PWR-75-24, PWR-120-48, PWR-240-48 and
PWR-480-48.
The indication will be the same, but a
different location.
Step 7: Please connect the power plug of the power cable to
a standard wall outlet, then it will power on the DC
Single Output Industrial DIN Rail Power Supply units.
When the DC Single Output Industrial DIN Rail Power Supply
units receive power, the “DC OK” LED should remain solid
Green.
Figure 2. "DC OK" LED of DC Single Output Industrial DIN Rail Power
Supply units.
Single Output Industrial DIN Rail Power Supply
(-10 ~ 70 degrees C)
PWR-480-48 (MEAN WELL/ SDR-480-48): l 480W 48V DC
Single Output Industrial DIN Rail Power Supply
(-25 ~ 70 degrees C)
Note
Strongly recommend to use 24V DC Single
Output Industrial DIN Rail Power Supply units
for Industrial Non-PoE equipment; 48V DC
Single Output Industrial DIN Rail Power Supply
units for Industrial PoE equipment.
The box should contain the following items:
The DC Single Output Industrial DIN Rail Power Supply Unit l
x 1
This User’s Manual x 1 l
If any item is found missing or damaged, please contact your
local reseller for replacement.
Step 3: Use Long Nose Pliers to remove the cover of 3 lines.
Step 6: Please connect the live line, null line and earth line to
the corresponding location.
Figure 1. Connect the 3 lines from AC Power Cord Cable to the
corresponding location.
Note
1. The example is based on PWR-40-24 for
PWR-75-24, PWR-120-48, PWR-240-48 and
PWR-480-48. The DC OK indication will be
the same, but in a different location.
2. +V ADJ. for O/P voltage adjustment (PWR-
40-24 / PWR-60-24 / PWR-480-48 only),
the range is 24V to 30V for PWR-40-24 /
PWR-60-24 and 48V to 55V for PWR-480-
48. Adjustable with screwdriver and voltage
measure with multimeter.
Warning
For PWR-120-48, one 115V AC / 230V AC
adjustable DIP switch is located on the bottom
of front panel. One 115V AC / 230V AC adjust-
able DIP switch (PWR-120-48 only), this is for
system input voltage selection. Please assure
the setting of AC DIP switch with local voltage
is compatible; otherwise, it will cause device
damage.
115V AC for 100V to 120V AC input voltage.
230V AC for 200V to 240V input voltage.
- 5- - 6 - - 7 - - 8 -
4. DC Power Terminal Block Installation
The DC Single Output Industrial DIN Rail Power Supply units
consist of two sets of DC power output contact and one set
of DC OK Relay contact (PWR-40-24, PWR-60-24 and
PWR-480-48 only).
Figure 3. DC Single Output Industrial DIN Rail Power Supply Upper
Panel.
Note
In this chapter, the example is based on
PWR-40-24 for PWR-75-24, PWR-120-48,
PWR-240-48 and PWR-480-48. There is no DC
OK Relay Contact, and a different DC voltage
output contact location.
Wiring the Power Inputs
The two sets of the DC power output contact of DC Single
Output Industrial DIN Rail Power Supply units are used for
connecting to terminal block with two DC redundant powers
input.
Note
Please do not connect the power plug of the
power cable to a standard wall outlet during
this installation.
Please follow the steps below to insert the power wire.
Step 1: PleasendoneterminalblockconnectorwithintwoDC
power inputs. The power contact distributor is shown
below:
Step 4: Tighten the wire-clamp screws for preventing the wires
from loosening.
V+ V+ V- V- Relay Contact
Step 5: Install the terminal block on PLANET Industrial
Ethernet equipment.
Step 6: Connect the power plug of the power cable to a
standard wall outlet; then the DC Single Output
Industrial DIN Rail Power Supply units will get
and provide power to PLANET Industrial Ethernet
equipment.
DC OK Relay Contact (PWR-40-24 / PWR-60-24 /
PWR-480-48 Only)
The PWR-40-24 / PWR-60-24 / PWR-480-48 DC Single Output
Industrial DIN Rail Power Supply unit provides DC OK Relay
Contact function, as the detailed description is shown below:
Contact Close When the output voltage reaches the
adjusted output voltage.
Contact Open When the output voltage drop below
90% of output voltage.
Contact Ratings (max.)
PWR-40-24 / PWR-60-24:
30V/1A resistive load.
PWR-480-48:
60V/0.3A, 30V/1A resistive load.
DIN-Rail Mounting
The DIN-Rail is equipped with the DC Single Output Industrial
DIN Rail Power Supply units when out of factory. To hang the
DC Single Output Industrial DIN Rail Power Supply units, follow
the steps below:
Note
1. The example is based on PWR-40-24 for
PWR-60-24, PWR-75-24, PWR-120-48,
PWR-240-48 and PWR-480-48. The installa-
tion will be the same.
2. Admissible DIN-RAIL: TS35/7.5 or TS35/15.
Step 1: Lightly press the bottom of DIN-Rail into the track.
Step 2: Check whether the DIN-Rail is tightly on the track.
Step 3: Please refer to the following procedures to remove the
DC Single Output Industrial DIN Rail Power Supply
units from the track.
Step 4: Lightly press the bottom of DIN-Rail to remove it from
the track.
5. Product Specications
Model
PWR-40-24
(MEAN WELL
/
MDR-40-24)
PWR-60-24
(MEAN WELL
/
MDR-60-24)
PWR-75-24
(MEAN WELL
/
DR-75-24)
HardwareSpecications
Dimensions
(W x H x D)
40 x 90 x 100
mm
40 x 90 x 100
mm
55 x 125 x 100
mm
Weight (kg) 0.3kg 0.3kg 0.6kg
Input
Voltage
100-240V AC,
50/60Hz, 1.1A
100-240V AC,
50/60Hz, 1.8A
100-240V AC,
50/60Hz, 2.0A
Power
Output
40 Watts, 24V,
1.7A
60 Watts, 24V,
2.5A
75 Watts, 24V,
3.2A
Temperature
Operating:
-20 ~ 70
degrees C
Storage:
-40 ~ 85
degrees C
Operating:
-20 ~ 70
degrees C
Storage:
-40 ~ 85
degrees C
Operating:
-10 ~ 60
degrees C
Storage:
-20 ~ 85
degrees C
Humidity Operating: 20 ~ 90%
Storage: 10 ~ 95% (non-condensing)
Installation DIN Rail TS-35/7.5 or 15
Safety &
Function*
PWR-40-24 (MEAN WELL / MDR-40-24):
UL508, UL60950-1, TUV EN60950-1
approved, NEC class 2 / LPS
compliant.
PWR-60-24 (MEAN WELL / MDR-60-24):
UL508, TUV EN60950-1 approved
PWR-75-24 (MEAN WELL / DR-75-24):
UL508, TUV EN60950-1 approved.
Model
PWR-120-48
(MEAN WELL
/
DR-120-48)
PWR-240-48
(MEAN WELL
/
DR-240-48)
PWR-480-48
(MEAN WELL
/
SDR-480-48)
HardwareSpecications
Dimensions
(W x H x D)
65 x 125 x 100
mm
125 x 125 x
100 mm
85.5 x 125.2 x
128.5 mm
Weight (kg) 0.79kg 1.2kg 1.6kg
Input
Voltage
100-240V AC,
50/60Hz, 3.3A
100-240V AC,
50/60Hz, 3.5A
100-240V AC,
50/60Hz, 5.0A
Power
Output
120 Watts, 48V,
2.5A
240 Watts, 48V,
5A
480 watts, 48V,
10A
Temperature
Operating:
-10 ~ 60
degrees C
Storage:
-20 ~ 85
degrees C
Operating:
-10 ~ 70
degrees C
Storage:
-20 ~ 85
degrees C
Operating:
-25 ~ 70
degrees C
Storage:
-25 ~ 85
degrees C
Humidity Operating: 20 ~ 90%
Storage: 10 ~ 95% (non-condensing)
Installation DIN Rail TS-35/7.5 or 15
Safety &
Function*
PWR-120-48 (MEAN WELL / DR-120-48):
UL508, UL60950-1, TUV EN60950-1
approved.
PWR-240-48 (MEAN WELL / DR-240-48):
UL508, UL60950-1, TUV EN60950-1
approved.
PWR-480-48 (MEAN WELL / SDR-480-48):
UL508, UL60950-1, TUV EN60950-1
approved.
* The power supply is considered a component which will be
installed into nal equipment. The nal equipment must be
re-conrmedthatitmeetsEMCdirective.
2351-AH0400-002
1 4 2 3 5 6
Power 1 Fault Power 2
- + - +
Note
The wire gauge for the terminal block should
be in the range between 12 and 24 AWG.
Step 2: Insert 4 DC power wires into the contacts 1 and 2 for
POWER 1, or 5 and 6 for POWER 2.
Step 3: Connect the 4 DC power wires from terminal block
to DC power output contact of DC Single Output
Industrial DIN Rail Power Supply units.
DC OK Relay Contact
Note
The wire gauge for the terminal block should
be in the range between 12 and 24 AWG.
1
2
1
2
Produktspezifikationen
Marke: | Planet |
Kategorie: | Computeradapter |
Modell: | PWR-75-24 |
Breite: | 55 mm |
Tiefe: | 100 mm |
Gewicht: | 600 g |
Produktfarbe: | Blue, Grey |
Höhe: | 125 mm |
Energieschutzeigenschaften: | Over voltage, Overheating, Overload, Short circuit |
AC Eingangsspannung: | 100 - 240 V |
AC Eingangsfrequenz: | 50 - 60 Hz |
DC input Spannung: | 120 - 370 V |
Betriebstemperatur: | -10 - 60 °C |
Relative Luftfeuchtigkeit in Betrieb: | 20 - 90 % |
Zertifizierung: | UL508, TUV EN60950-1 |
Warentarifnummer (HS): | 84733020 |
Leistung: | 75 W |
Temperaturbereich bei Lagerung: | -20 - 85 °C |
Luftfeuchtigkeit bei Lagerung: | 10 - 95 % |
Anzahl: | 1 |
Ausgangsstrom: | 3200 mA |
Ausgangsspannung: | 24 V |
Eingangsstrom: | 1.45 A |
Sicherheit: | Ul508, TUV EN60950-1 |
Kühlung: | Passiv |
Gesamtleistung: | 75 W |
DIN-Schienen-Montage: | Ja |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Planet PWR-75-24 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Computeradapter Planet
7 Mai 2023
Bedienungsanleitung Computeradapter
- Computeradapter Corsair
- Computeradapter Gigabyte
- Computeradapter Pyle
- Computeradapter Fantec
- Computeradapter Ewent
- Computeradapter LC-Power
- Computeradapter MSI
- Computeradapter Ansmann
- Computeradapter Cooler Master
- Computeradapter Delta
- Computeradapter Be Quiet!
- Computeradapter Akasa
- Computeradapter Steren
- Computeradapter Zippy
- Computeradapter Xilence
- Computeradapter Antec
- Computeradapter StarTech.com
- Computeradapter AeroCool
- Computeradapter CLUB3D
- Computeradapter Fractal Design
- Computeradapter ENDORFY
- Computeradapter Seasonic
- Computeradapter Mini-Box
- Computeradapter FSP
- Computeradapter DeepCool
- Computeradapter FSP/Fortron
Neueste Bedienungsanleitung für -Kategorien-
15 August 2024
25 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
23 Juni 2024
20 Juni 2024
20 Juni 2024