Planet MC-1500R Bedienungsanleitung


Lesen Sie kostenlos die πŸ“– deutsche Bedienungsanleitung fΓΌr Planet MC-1500R (4 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war fΓΌr 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/4
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Package Contents
Before start installing the Converter, verify the package
contains the following parts:
β—ξ˜ƒ Theξ˜ƒMediaξ˜ƒConverterξ˜ƒChassisξ˜ƒxξ˜ƒ1
β—ξ˜ƒ User'sξ˜ƒManualξ˜ƒxξ˜ƒ1
β—ξ˜ƒ Mountingξ˜ƒAccessoryξ˜ƒ(forξ˜ƒ10/19β€ξ˜ƒChassisξ˜ƒShelf)ξ˜ƒxξ˜ƒ1
β—ξ˜ƒ Rubberξ˜ƒFeetξ˜ƒxξ˜ƒ4
β—ξ˜ƒ ACξ˜ƒPowerξ˜ƒCordξ˜ƒxξ˜ƒ1
Ifξ˜ƒanyξ˜ƒofξ˜ƒtheseξ˜ƒareξ˜ƒmissingξ˜ƒorξ˜ƒdamaged,ξ˜ƒpleaseξ˜ƒcontactξ˜ƒyourξ˜ƒ
dealerξ˜ƒ immediately,ξ˜ƒ ifξ˜ƒ possible,ξ˜ƒ retainξ˜ƒ theξ˜ƒ cartonξ˜ƒ includingξ˜ƒ
theξ˜ƒ originalξ˜ƒ packingξ˜ƒ material,ξ˜ƒ andξ˜ƒ useξ˜ƒ themξ˜ƒ againstξ˜ƒ toξ˜ƒ
repackξ˜ƒtheξ˜ƒproductξ˜ƒinξ˜ƒcaseξ˜ƒthereξ˜ƒisξ˜ƒaξ˜ƒneedξ˜ƒtoξ˜ƒreturnξ˜ƒitξ˜ƒtoξ˜ƒusξ˜ƒ
for repair.
3. Media Converter Chassis
Front Panel
Figureξ˜ƒ 3-1ξ˜ƒ &ξ˜ƒ 3-2ξ˜ƒ &ξ˜ƒ 3-3ξ˜ƒ showsξ˜ƒ aξ˜ƒ frontξ˜ƒ panelξ˜ƒ ofξ˜ƒ MC-700ξ˜ƒ /ξ˜ƒ
MC-1500ξ˜ƒ/ξ˜ƒMC-1500Rξ˜ƒ/ξ˜ƒMC-1500R48.
Figure 3-1 MC-700 Front Panel
Figure 3-2 MC-1500 Front Panel
Figure 3-3 MC-1500R / 1500R48 Front Panel
6. Installing the Media Converter
Chassis
6.1 Installing Media Converter Chassis to
10/19-inch Wiring Closet Rack
Β»ξ˜ƒ Installξ˜ƒfourξ˜ƒscrewsξ˜ƒthroughξ˜ƒmountingξ˜ƒearsξ˜ƒintoξ˜ƒeachξ˜ƒside.
Β»ξ˜ƒ Locateξ˜ƒ Converterξ˜ƒ Chassisξ˜ƒ atξ˜ƒ 10/19-inchξ˜ƒ mountingξ˜ƒ railsξ˜ƒ
andξ˜ƒscrewξ˜ƒupξ˜ƒtheξ˜ƒfrontξ˜ƒbrackets.
Β»ξ˜ƒ Setξ˜ƒ Mainξ˜ƒ powerξ˜ƒ switchξ˜ƒ atξ˜ƒ β€œOFFβ€ξ˜ƒ positionξ˜ƒ beforeξ˜ƒ
connectingξ˜ƒtheξ˜ƒpowerξ˜ƒcord.
Figure 6-1 Installingξ˜ƒMediaξ˜ƒChassisξ˜ƒinξ˜ƒWiringξ˜ƒClosetξ˜ƒRails
5. Media Converter Chassis
Rear Panel
Figureξ˜ƒ 5-1ξ˜ƒ &ξ˜ƒ 5-2ξ˜ƒ &ξ˜ƒ 5-3ξ˜ƒ showsξ˜ƒ aξ˜ƒ rearξ˜ƒ panelξ˜ƒ ofξ˜ƒ MC-700ξ˜ƒ /ξ˜ƒ
MC-1500ξ˜ƒ/ξ˜ƒMC-1500Rξ˜ƒ/ξ˜ƒMC-1500R48.
Theξ˜ƒ rearξ˜ƒ panelξ˜ƒ ofξ˜ƒ theξ˜ƒ MC-700ξ˜ƒ isξ˜ƒ withξ˜ƒ oneξ˜ƒ fan,ξ˜ƒ oneξ˜ƒ ON/
OFFξ˜ƒ Switchξ˜ƒ andξ˜ƒ aξ˜ƒ powerξ˜ƒ inletξ˜ƒ thatξ˜ƒ acceptξ˜ƒ 100~240Vξ˜ƒ AC,ξ˜ƒ
50/60Hzξ˜ƒpowerξ˜ƒinput.
Figure 5-1 MC-700 Rear Panel
Theξ˜ƒ rearξ˜ƒ panelξ˜ƒ ofξ˜ƒ theξ˜ƒ MC-1500ξ˜ƒ isξ˜ƒ withξ˜ƒ twoξ˜ƒ fans,ξ˜ƒ oneξ˜ƒ ON/
OFFξ˜ƒ Switchξ˜ƒ andξ˜ƒ aξ˜ƒ powerξ˜ƒ inletξ˜ƒ thatξ˜ƒ acceptξ˜ƒ 100~240Vξ˜ƒ AC,ξ˜ƒ
50/60Hzξ˜ƒpowerξ˜ƒinput.
Figure 5-2 MC-1500 Rear Panel
2. Product Features
β—ξ˜ƒ Highξ˜ƒqualityξ˜ƒ10"
/
19β€ξ˜ƒRack-Mountableξ˜ƒChassisξ˜ƒinstallation
β—ξ˜ƒ Supportsξ˜ƒ upξ˜ƒ toξ˜ƒ sevenξ˜ƒ (7)ξ˜ƒ /ξ˜ƒ fteenξ˜ƒ (15)ξ˜ƒ hot-swappableξ˜ƒ
mediaξ˜ƒconverters
β—ξ˜ƒ Oneξ˜ƒ fanξ˜ƒ bringsξ˜ƒ theξ˜ƒ air-owξ˜ƒ forξ˜ƒ systemξ˜ƒ cooling,ξ˜ƒ andξ˜ƒ LEDξ˜ƒ
indicatorsξ˜ƒforξ˜ƒsystemξ˜ƒandξ˜ƒfanξ˜ƒstatusξ˜ƒ(MC-700)
β—ξ˜ƒ Twoξ˜ƒ fanξ˜ƒ bringsξ˜ƒ theξ˜ƒ air-owξ˜ƒ forξ˜ƒ systemξ˜ƒ cooling,ξ˜ƒ andξ˜ƒ LEDξ˜ƒ
indicatorsξ˜ƒforξ˜ƒ systemξ˜ƒandξ˜ƒfanξ˜ƒstatusξ˜ƒ(MC-1500ξ˜ƒ /ξ˜ƒ1500Rξ˜ƒ/ξ˜ƒ
1500R48)
β—ξ˜ƒ Theξ˜ƒpowerξ˜ƒslotξ˜ƒatξ˜ƒrearξ˜ƒpanelξ˜ƒforξ˜ƒredundantξ˜ƒpowerξ˜ƒsupportξ˜ƒ
withξ˜ƒ optionsξ˜ƒ ofξ˜ƒ 100~240Vξ˜ƒ ACξ˜ƒ orξ˜ƒ -48Vξ˜ƒ DCξ˜ƒ suppliesξ˜ƒ
(MC-1500Rξ˜ƒ/ξ˜ƒ1500R48)
β—ξ˜ƒ Bayξ˜ƒ powerξ˜ƒ isolation,ξ˜ƒ ensureξ˜ƒ eachξ˜ƒ bayξ˜ƒ isξ˜ƒ electricallyξ˜ƒ
isolatedξ˜ƒfromξ˜ƒeachξ˜ƒother
β—ξ˜ƒ Supportξ˜ƒ multipleξ˜ƒ convertersξ˜ƒ withξ˜ƒ 10/100/1000Mbps,ξ˜ƒ
copper,ξ˜ƒFiber,ξ˜ƒsingle/multi-modeξ˜ƒST/SC/SFPξ˜ƒconnectors
β—ξ˜ƒ Reduceξ˜ƒtheξ˜ƒeffortξ˜ƒ ofξ˜ƒconverterξ˜ƒmaintenanceξ˜ƒ andξ˜ƒmanage-
ment,ξ˜ƒdiagnoseξ˜ƒtheξ˜ƒstatusξ˜ƒatξ˜ƒoneξ˜ƒtime
β—ξ˜ƒ Cost-effective,ξ˜ƒeasyξ˜ƒinstall
4. LED Indicators
MC-700
Printing LED
Status Description
PWR
ON Theξ˜ƒchassisξ˜ƒisξ˜ƒpowered.
OFF
Theξ˜ƒchassisξ˜ƒisξ˜ƒnotξ˜ƒpoweredξ˜ƒorξ˜ƒpowerξ˜ƒ
failure,ξ˜ƒifξ˜ƒtheξ˜ƒACξ˜ƒoutletξ˜ƒisξ˜ƒwithξ˜ƒ
100~240Vξ˜ƒACξ˜ƒvoltage.ξ˜ƒPleaseξ˜ƒconsultξ˜ƒ
yourξ˜ƒlocalξ˜ƒdealerξ˜ƒifξ˜ƒpowerξ˜ƒfailure.
FAN
ON Theξ˜ƒfanξ˜ƒisξ˜ƒfunctionalξ˜ƒok.
OFF
Theξ˜ƒfanξ˜ƒisξ˜ƒnotξ˜ƒpoweredξ˜ƒorξ˜ƒitξ˜ƒisξ˜ƒ
malfunction.ξ˜ƒIfξ˜ƒtheξ˜ƒfanξ˜ƒLEDξ˜ƒremainsξ˜ƒ
offξ˜ƒwhileξ˜ƒpowerξ˜ƒisξ˜ƒon.ξ˜ƒPleaseξ˜ƒconsultξ˜ƒ
yourξ˜ƒlocalξ˜ƒdealerξ˜ƒtoξ˜ƒreplaceξ˜ƒtheξ˜ƒFAN.
MC-1500 Series
Printing LED
Status Description
PWR
ON Theξ˜ƒchassisξ˜ƒisξ˜ƒpowered.
OFF Theξ˜ƒchassisξ˜ƒisξ˜ƒnotξ˜ƒpoweredξ˜ƒorξ˜ƒpowerξ˜ƒ
failure.
FANξ˜ƒAξ˜ƒ/ξ˜ƒ
FANξ˜ƒB
ON Theξ˜ƒfanξ˜ƒisξ˜ƒfunctionalξ˜ƒO.K.
OFF
Theξ˜ƒfanξ˜ƒisξ˜ƒnotξ˜ƒpoweredξ˜ƒorξ˜ƒitξ˜ƒisξ˜ƒ
malfunction.ξ˜ƒIfξ˜ƒtheξ˜ƒfanξ˜ƒLEDξ˜ƒremainsξ˜ƒ
offξ˜ƒwhileξ˜ƒpowerξ˜ƒisξ˜ƒon.ξ˜ƒPleaseξ˜ƒconsultξ˜ƒ
yourξ˜ƒlocalξ˜ƒdealerξ˜ƒtoξ˜ƒreplaceξ˜ƒtheξ˜ƒFAN.
Theξ˜ƒrearξ˜ƒpanelξ˜ƒofξ˜ƒtheξ˜ƒMC-1500Rξ˜ƒ/ξ˜ƒ1500R48.
Figure 5-3 MC-1500R / 1500R48 Rear Panel
Note
1.ξ˜ƒTheξ˜ƒMC-1500Rξ˜ƒshippedξ˜ƒwithξ˜ƒoneξ˜ƒ100~240Vξ˜ƒ
ACξ˜ƒpowerξ˜ƒsupplyξ˜ƒmoduleξ˜ƒ(MC-15RPS130).
2.ξ˜ƒTheξ˜ƒMC-1500R48ξ˜ƒshippedξ˜ƒwithξ˜ƒoneξ˜ƒDCξ˜ƒ-48Vξ˜ƒ
powerξ˜ƒsupplyξ˜ƒmoduleξ˜ƒ(MC-15RPS48).
Power
Notice
1.ξ˜ƒTheξ˜ƒdeviceξ˜ƒisξ˜ƒaξ˜ƒpower-requiredξ˜ƒdevice,ξ˜ƒitξ˜ƒ
means,ξ˜ƒitξ˜ƒwillξ˜ƒnotξ˜ƒworkξ˜ƒtillξ˜ƒitξ˜ƒisξ˜ƒpowered.ξ˜ƒ
Ifξ˜ƒyourξ˜ƒnetworksξ˜ƒshouldξ˜ƒactiveξ˜ƒallξ˜ƒtheξ˜ƒ
time,ξ˜ƒpleaseξ˜ƒconsiderξ˜ƒuseξ˜ƒaξ˜ƒproperξ˜ƒUPSξ˜ƒ
(Uninterruptedξ˜ƒPowerξ˜ƒSupply)ξ˜ƒforξ˜ƒyourξ˜ƒ
device.ξ˜ƒItξ˜ƒwillξ˜ƒpreventξ˜ƒyouξ˜ƒfromξ˜ƒnetworkξ˜ƒ
dataξ˜ƒlossξ˜ƒorξ˜ƒnetworkξ˜ƒdowntime.
2.ξ˜ƒInξ˜ƒsomeξ˜ƒarea,ξ˜ƒinstallingξ˜ƒaξ˜ƒsurgeξ˜ƒ
suppressionξ˜ƒdeviceξ˜ƒmayξ˜ƒalsoξ˜ƒhelpξ˜ƒtoξ˜ƒ
protectξ˜ƒyourξ˜ƒchassisξ˜ƒfromξ˜ƒbeingξ˜ƒdamagedξ˜ƒ
byξ˜ƒunregulatedξ˜ƒsurgeξ˜ƒorξ˜ƒcurrentξ˜ƒtoξ˜ƒtheξ˜ƒ
converterξ˜ƒorξ˜ƒtheξ˜ƒpowerξ˜ƒadapter.
Rack Mount Instructions
A)ξ˜ƒ Elevatedξ˜ƒ Operatingξ˜ƒ Ambientξ˜ƒ -ξ˜ƒ Ifξ˜ƒ installedξ˜ƒ inξ˜ƒ aξ˜ƒ closedξ˜ƒ orξ˜ƒ
multi-unitξ˜ƒrackξ˜ƒassembly,ξ˜ƒtheξ˜ƒoperatingξ˜ƒambientξ˜ƒtemper-
atureξ˜ƒ ofξ˜ƒ theξ˜ƒ rackξ˜ƒ environmentξ˜ƒ mayξ˜ƒ beξ˜ƒ greaterξ˜ƒ thanξ˜ƒ
roomξ˜ƒ ambient.ξ˜ƒTherefore,ξ˜ƒconsiderationξ˜ƒshouldξ˜ƒbeξ˜ƒgivenξ˜ƒ
toξ˜ƒ installingξ˜ƒ theξ˜ƒ equipmentξ˜ƒ inξ˜ƒ anξ˜ƒ environmentξ˜ƒ compat-
ibleξ˜ƒ withξ˜ƒ theξ˜ƒ maximumξ˜ƒ ambientξ˜ƒ temperatureξ˜ƒ (Tma)ξ˜ƒ
speciedξ˜ƒbyξ˜ƒtheξ˜ƒmanufacturer.
B)ξ˜ƒ Reducedξ˜ƒ Airξ˜ƒ Flowξ˜ƒ -ξ˜ƒ Installationξ˜ƒ ofξ˜ƒ theξ˜ƒ equipmentξ˜ƒ inξ˜ƒ aξ˜ƒ
rackξ˜ƒshouldξ˜ƒbeξ˜ƒsuchξ˜ƒthatξ˜ƒtheξ˜ƒamountξ˜ƒofξ˜ƒairξ˜ƒξ›€owξ˜ƒrequiredξ˜ƒ
forξ˜ƒsafeξ˜ƒoperationξ˜ƒofξ˜ƒtheξ˜ƒequipmentξ˜ƒisξ˜ƒnotξ˜ƒcompromised.
C)ξ˜ƒ Mechanicalξ˜ƒ Loadingξ˜ƒ -ξ˜ƒ Mountingξ˜ƒ ofξ˜ƒ theξ˜ƒ equipmentξ˜ƒ inξ˜ƒ theξ˜ƒ
rackξ˜ƒ shouldξ˜ƒ beξ˜ƒ suchξ˜ƒ thatξ˜ƒ aξ˜ƒ hazardousξ˜ƒ conditionξ˜ƒ isξ˜ƒ notξ˜ƒ
achievedξ˜ƒdueξ˜ƒtoξ˜ƒunevenξ˜ƒmechanicalξ˜ƒloading.
D)ξ˜ƒ Circuitξ˜ƒ Overloadingξ˜ƒ -ξ˜ƒ Considerationξ˜ƒ shouldξ˜ƒ beξ˜ƒ givenξ˜ƒ toξ˜ƒ
theξ˜ƒ connectionξ˜ƒ ofξ˜ƒ theξ˜ƒ equipmentξ˜ƒ toξ˜ƒ theξ˜ƒ supplyξ˜ƒ circuitξ˜ƒ
andξ˜ƒtheξ˜ƒeffectξ˜ƒthatξ˜ƒoverloadingξ˜ƒofξ˜ƒtheξ˜ƒcircuitsξ˜ƒmightξ˜ƒhaveξ˜ƒ
onξ˜ƒovercurrentξ˜ƒprotectionξ˜ƒandξ˜ƒsupplyξ˜ƒwiring.ξ˜ƒAppropriateξ˜ƒ
considerationξ˜ƒofξ˜ƒequipmentξ˜ƒnameplateξ˜ƒratingsξ˜ƒ shouldξ˜ƒbeξ˜ƒ
usedξ˜ƒwhenξ˜ƒaddressingξ˜ƒthisξ˜ƒconcern.
E)ξ˜ƒ Reliableξ˜ƒ Earthingξ˜ƒ -ξ˜ƒ Reliableξ˜ƒ earthingξ˜ƒ ofξ˜ƒ rack-mountedξ˜ƒ
equipmentξ˜ƒ shouldξ˜ƒ beξ˜ƒ maintained.ξ˜ƒ Particularξ˜ƒ attentionξ˜ƒ
shouldξ˜ƒ beξ˜ƒ givenξ˜ƒ toξ˜ƒ supplyξ˜ƒ connectionsξ˜ƒ otherξ˜ƒthanξ˜ƒ directξ˜ƒ
connectionsξ˜ƒ toξ˜ƒ theξ˜ƒ branchξ˜ƒ circuitξ˜ƒ (e.g.ξ˜ƒ useξ˜ƒ ofξ˜ƒ powerξ˜ƒ
strips)."
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
6.2 Installing Converters to the Media Converter
Chassis
Β»ξ˜ƒ Turnξ˜ƒoffξ˜ƒtheξ˜ƒConverterξ˜ƒChassisξ˜ƒpower.
Β»ξ˜ƒ Verifyξ˜ƒ theξ˜ƒ Mediaξ˜ƒ Converterξ˜ƒ isξ˜ƒ rightξ˜ƒ forξ˜ƒ thisξ˜ƒ Chassisξ˜ƒ andξ˜ƒ
locateξ˜ƒ +5VDCξ˜ƒ powerξ˜ƒ jackξ˜ƒ onξ˜ƒ converterξ˜ƒ back,ξ˜ƒ carefullyξ˜ƒ
slideξ˜ƒ inξ˜ƒ andξ˜ƒ plugξ˜ƒ toξ˜ƒ matchξ˜ƒ 10”/19β€ξ˜ƒ Chassisξ˜ƒ slotξ˜ƒ +5Vξ˜ƒ
DCξ˜ƒ receptacle.ξ˜ƒ Pushξ˜ƒ upξ˜ƒ theξ˜ƒ picketξ˜ƒ fenceξ˜ƒ toξ˜ƒ lockξ˜ƒ theξ˜ƒ
converters.
Note
Theξ˜ƒ slide-inξ˜ƒ Mediaξ˜ƒ Convertersξ˜ƒ andξ˜ƒ Converterξ˜ƒ
Chassisξ˜ƒ shouldξ˜ƒ beξ˜ƒ suppliedξ˜ƒ onlyξ˜ƒ fromξ˜ƒ PLANET,ξ˜ƒ
bothξ˜ƒ Mediaξ˜ƒ Convertersξ˜ƒ andξ˜ƒ Chassisξ˜ƒ areξ˜ƒ builtξ˜ƒ
toξ˜ƒ matchξ˜ƒeachξ˜ƒotherξ˜ƒ atξ˜ƒdimensions,ξ˜ƒDCξ˜ƒpowerξ˜ƒ
jack,ξ˜ƒandξ˜ƒDCξ˜ƒreceptacleξ˜ƒandξ˜ƒpowerξ˜ƒsafety.
Β»ξ˜ƒ Ensureξ˜ƒthatξ˜ƒthereξ˜ƒisξ˜ƒnoξ˜ƒactivityξ˜ƒinξ˜ƒtheξ˜ƒnetwork.
Β»ξ˜ƒ Connectξ˜ƒtheξ˜ƒmediaξ˜ƒcableξ˜ƒforξ˜ƒnetworkξ˜ƒconnection.
Β»ξ˜ƒ Turnξ˜ƒonξ˜ƒtheξ˜ƒ chassisξ˜ƒpower,ξ˜ƒ theξ˜ƒ Powerξ˜ƒLED,ξ˜ƒandξ˜ƒbothξ˜ƒ FANξ˜ƒ
LEDξ˜ƒindicatorsξ˜ƒwillξ˜ƒlightξ˜ƒup.
7. Product Specications
MC-700 Converter Chassis Specications
Dimension 217ξ˜ƒmmξ˜ƒxξ˜ƒ88.5ξ˜ƒmmξ˜ƒxξ˜ƒ140ξ˜ƒmm
(Wξ˜ƒxξ˜ƒHξ˜ƒxξ˜ƒD),ξ˜ƒ2Uξ˜ƒheight
Converter Slots 7ξ˜ƒslots
Power Input 100~240Vξ˜ƒAC,ξ˜ƒ50/60Hz
Power
Consumption 40ξ˜ƒWattsξ˜ƒmaximumξ˜ƒ/ξ˜ƒ136BTU
Power Output
Per Slot +5Vξ˜ƒDC
DC Plug Per Slot 2.5ξ˜ƒmmξ˜ƒDCξ˜ƒreceptacle
LED Indication 2;ξ˜ƒPower,ξ˜ƒFAN
FAN 1
Temperature /
Humidity
Operating Environment
0~50ξ˜ƒDegreeξ˜ƒC;ξ˜ƒHumidity:ξ˜ƒ5~90%ξ˜ƒ
non-condensing
Storage Environment
-40~70ξ˜ƒDegreeξ˜ƒC;ξ˜ƒHumidity:ξ˜ƒ5~90%ξ˜ƒ
non-condensing
Emission FCCξ˜ƒPartξ˜ƒ15ξ˜ƒClassξ˜ƒA,ξ˜ƒCE
6.3 Converter Check Point
Fiber
Port
Attachξ˜ƒtheξ˜ƒξšΏberξ˜ƒ
cable.ξ˜ƒTheξ˜ƒTx,ξ˜ƒ
Rxξ˜ƒξšΏberξ˜ƒcableξ˜ƒ
mustξ˜ƒbeξ˜ƒpairedξ˜ƒ
atξ˜ƒbothξ˜ƒends.
2.5mm
DCξ˜ƒReceptacleξ˜ƒ2.5mm
+5Vξ˜ƒforξ˜ƒeachξ˜ƒslot
DCξ˜ƒreceptacleξ˜ƒisξ˜ƒ2.5mmξ˜ƒwideξ˜ƒ
thatξ˜ƒconformsξ˜ƒtoξ˜ƒandξ˜ƒmatchesξ˜ƒ
theξ˜ƒMediaξ˜ƒConverterξ˜ƒ2.5mmξ˜ƒDCξ˜ƒ
jack'sξ˜ƒcentralξ˜ƒpole.ξ˜ƒDoξ˜ƒnotξ˜ƒinstallξ˜ƒ
anyξ˜ƒimproperξ˜ƒunit,ξ˜ƒmodelξ˜ƒofξ˜ƒtheξ˜ƒ
Mediaξ˜ƒConverter.
TP
Port
Attach UTP
Cat. 3 or 5 ca-
ble to TP port.
Note
Forξ˜ƒ safetyξ˜ƒ reason,ξ˜ƒ itξ˜ƒ isξ˜ƒ recommendedξ˜ƒ storingξ˜ƒ
theξ˜ƒ ACξ˜ƒ adapterξ˜ƒ ofξ˜ƒ theξ˜ƒ converterξ˜ƒ inξ˜ƒ aξ˜ƒ knownξ˜ƒ
securedξ˜ƒplace.ξ˜ƒForξ˜ƒmoreξ˜ƒaboutξ˜ƒconverter,ξ˜ƒreferξ˜ƒ
toξ˜ƒtheξ˜ƒuserξ˜ƒ guideξ˜ƒofξ˜ƒtheξ˜ƒconverter.
MC-1500 Converter Chassis Specications
Dimension 440ξ˜ƒmmξ˜ƒxξ˜ƒ103ξ˜ƒmmξ˜ƒxξ˜ƒ180ξ˜ƒmm
(Wξ˜ƒxξ˜ƒHξ˜ƒxξ˜ƒD),ξ˜ƒ2.4Uξ˜ƒheight
Converter Slots 15ξ˜ƒslots
Power Input 100~240Vξ˜ƒAC,ξ˜ƒ50/60Hz
Power
Consumption 70ξ˜ƒWattsξ˜ƒmaximumξ˜ƒ/ξ˜ƒ238BTU
Power Output
Per Slot +5Vξ˜ƒDC
DC Plug Per Slot 2.5ξ˜ƒmmξ˜ƒDCξ˜ƒreceptacle
LED Indication 3;ξ˜ƒPowerξ˜ƒ1,ξ˜ƒFANξ˜ƒA,ξ˜ƒFANξ˜ƒB
FAN 2
Temperature /
Humidity
Operating Environment
0~50ξ˜ƒDegreeξ˜ƒC;ξ˜ƒHumidity:ξ˜ƒ5~90%ξ˜ƒ
non-condensing
Storage Environment
-40~70ξ˜ƒDegreeξ˜ƒC;ξ˜ƒHumidity:ξ˜ƒ5~90%ξ˜ƒ
non-condensing
Emission FCCξ˜ƒPartξ˜ƒ15ξ˜ƒClassξ˜ƒA,ξ˜ƒCE
MC-1500R / MC-1500R48 Converter Chassis
Specications
Model MC-1500R MC-1500R48
Dimension 440ξ˜ƒmmξ˜ƒxξ˜ƒ103ξ˜ƒmmξ˜ƒxξ˜ƒ180ξ˜ƒmm
(Wξ˜ƒxξ˜ƒHξ˜ƒxξ˜ƒD),ξ˜ƒ2.4Uξ˜ƒheight
Converter Slots 15ξ˜ƒslots
Power Input 100~240Vξ˜ƒAC,ξ˜ƒ
3.3A,ξ˜ƒ50-60Hz
DCξ˜ƒ-48V,ξ˜ƒ2A,
Range:ξ˜ƒ-40Vξ˜ƒ~ξ˜ƒ-60V
Power
Consumption
10.7ξ˜ƒWattsξ˜ƒ/ξ˜ƒ36BTU
(1ξ˜ƒxξ˜ƒpowerξ˜ƒsupply,
notξ˜ƒincludeξ˜ƒ
converters)
88.3ξ˜ƒWattsξ˜ƒ/ξ˜ƒ301BTUξ˜ƒ
(Fullξ˜ƒloading)
5.3ξ˜ƒWattsξ˜ƒ/ξ˜ƒ18BTU
(1ξ˜ƒxξ˜ƒpowerξ˜ƒsupply,
notξ˜ƒincludeξ˜ƒ
converters)
80ξ˜ƒWattsξ˜ƒ/ξ˜ƒ272BTUξ˜ƒ
(Fullξ˜ƒloading)
Power Output
Per Slot Eachξ˜ƒslotξ˜ƒ5V
1A
DC Plug Per
Slot 2.5ξ˜ƒmmξ˜ƒDCξ˜ƒreceptacle
LED Indication 4;ξ˜ƒPowerξ˜ƒ1,ξ˜ƒPowerξ˜ƒ2,ξ˜ƒFANξ˜ƒA,ξ˜ƒFANξ˜ƒB
FAN 2
Temperature /
Humidity
Operating Environment
0~50ξ˜ƒDegreeξ˜ƒC;ξ˜ƒHumidity:ξ˜ƒ5~90%
non-condensing
Storage Environment
-40~70ξ˜ƒDegreeξ˜ƒC;ξ˜ƒHumidity:ξ˜ƒ5~90%
non-condensing
Emission FCCξ˜ƒPartξ˜ƒ15ξ˜ƒClassξ˜ƒA,ξ˜ƒCE
8. Customer Support
Thankξ˜ƒ youξ˜ƒ forξ˜ƒ purchaseξ˜ƒ PLANETξ˜ƒ products.ξ˜ƒ Youξ˜ƒ canξ˜ƒ browseξ˜ƒ
ourξ˜ƒ onlineξ˜ƒ FAQξ˜ƒ resourceξ˜ƒ atξ˜ƒ theξ˜ƒ PLANETξ˜ƒ Webξ˜ƒ siteξ˜ƒ rstξ˜ƒ toξ˜ƒ
checkξ˜ƒ ifξ˜ƒ itξ˜ƒ couldξ˜ƒ solveξ˜ƒyouξ˜ƒ issue.ξ˜ƒ Ifξ˜ƒ youξ˜ƒ needξ˜ƒ moreξ˜ƒsupportξ˜ƒ
information,ξ˜ƒpleaseξ˜ƒcontactξ˜ƒPLANETξ˜ƒMediaξ˜ƒConverterξ˜ƒsupportξ˜ƒ
team.
PLANETξ˜ƒonlineξ˜ƒFAQξ˜ƒ:
http://www.planet.com.tw/en/support/faq.php?type=3
Mediaξ˜ƒConverterξ˜ƒsupportξ˜ƒteamξ˜ƒmailξ˜ƒaddressξ˜ƒ:
support_converter@planet.com.tw
Copyright Β© PLANET Technology Corp. 2012.
Contents subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All other
trademarks belong to their respective owners.


Produktspezifikationen

Marke: Planet
Kategorie: Nicht kategorisiert
Modell: MC-1500R
Breite: 438 mm
Tiefe: 200 mm
Gewicht: 4300 g
Produktfarbe: Schwarz
Übertragungstechnik: Kabelgebunden
HΓΆhe: 103 mm
AC Eingangsspannung: 100 - 240 V
AC Eingangsfrequenz: 50 - 60 Hz
Betriebstemperatur: 0 - 50 Β°C
Relative Luftfeuchtigkeit in Betrieb: 5 - 90 %
Zertifizierung: FCC Class A, CE
Stromverbrauch (Standardbetrieb): 80 W
Warentarifnummer (HS): 85176990
Plug & Play: Ja
Ethernet LAN Datentransferraten: 1000,100 Mbit/s
Eingebaut: Ja
LED-Anzeigen: Ja
Temperaturbereich bei Lagerung: -20 - 70 Β°C
Luftfeuchtigkeit bei Lagerung: 5 - 90 %
Rack-Einbau: Ja
Grâße (Imperial): 19 "
Ausgangsstrom: 1 A
Ausgangsspannung: 5 V
Ethernet Schnittstellen Typ: Fast Ethernet, Gigabit Ethernet
Eingangsstrom: 3.3 A
Anzahl LΓΌfter: 2 LΓΌfter
KΓΌhlung: Aktiv
Rack-KapazitΓ€t: 2.4U
Anzahl Slots: 15

Brauchst du Hilfe?

Wenn Sie Hilfe mit Planet MC-1500R benΓΆtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Planet

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fΓΌr -Kategorien-