1. Package Contents
Thank you for purchasing PLANET industrial Gigabit Media Converter,
IGT-805AT. In the following sections, the term Industrial Gigabit
Media Converter mentioned in this user’s manual also means the
IGT-805AT.
Open the box of the Industrial Gigabit Media Converter and
carefully unpack it. The box should contain the following items:
Industrial Gigabit
Media Converter x 1 User's Manual x 1 Wall-mount Plate w/
Screws x 1
DIN-rail Bracket
w/Screws x 1 RJ45 Dust Cap x 1 SFP Dust Cap x 1
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original
packing material, and use them again to repack the product in case
there is a need to return it to us for repair.
Weight 395g
Power Requirements
DC 12~48V, redundant power with reverse
polarity protection function.
AC 24V power adapter
Power
Consumption/
Dissipation
2.6 watts/8.8BTU (DC 48V)
Converter Specications
Flow Control Back pressure for half duplex.
IEEE 802.3x pause frame for full duplex
Fabric 4Gbps
Throughput
(packet per second) 2.97Mpps@64bytes
Maximum
Transmission Unit 9216 bytes
Network Cables
10/100/1000BASE-T:
Cat3, 4, 5, 5e, 6 UTP cable
(100 meters, max.)
EIA/TIA-568 100-ohm STP
(100 meters, max.)
1000BASE-SX:
50/125μm or 62.5/125μm multi-mode
ber optic cable, up to 550m
(varying on SFP module)
1000BASE-LX:
9/125μm single-mode ber optic cable,
up to 10/20/40/60/80/120 kilometers
(varying on SFP module)
3.2 LED Indicators
System
LED Color Function
P1 Green Lit: indicates power 1 has power.
P2 Green Lit: indicates power 2 has power.
Alarm Red Lit: indicates either power 1 or power 2 has no
power.
Per 100/1000BASE-X SFP Port
LED Color Function
LNK/
ACT Green
Lit: indicates the link through that port is
successfully established at 100Mbps or 1000Mbps.
Blinking: indicates that the Converter is actively
sending or receiving data over that port.
Per 10/100/1000BASE-T Port
LED Color Function
LNK/
ACT Green
Lit: indicates that the Gigabit Ethernet Port
is successfully connecting to the network at
10/100/1000Mbps.
Blinking: indicates that the Gigabit Ethernet Port
is actively sending or receiving data over that port.
1000
LNK/
ACT
Green
Lit: indicates the link through that port is
successfully established at 1000Mbps.
Blinking: indicates that the Gigabit Ethernet Port
is actively sending or receiving data over that port.
O: indicates the link through that port is
successfully established at 10/100Mbps.
3. Hardware Introduction
3.1 Three-View Diagram
The three-view diagram of the Industrial Gigabit Media Converter
consists of Ethernet interfaces and one removable 6-pin terminal
block. The LED indicators are also located on the front panel.
IGT-805AT:
32.00
135.00
87.80
97.10
48.8046.50 39.70
28.00
48.80
53.50 53.50
18.00
15.20
30.00
9.20
40.00
28.0018.00
28.00
18.0028.00
28.00
40.00
163.00
Top View
Side View Front View
Mounting Kit
Mounting Kit
DIN-Rail Kit
Side View Rear View
Unit: mm
Bottom View
P1 P2
LNK /
ACT
LNK /ACT
1000
Alarm
100/1000X
10/100/1000T
Max. Fault Ala rm Loading: 24V, 1A
DC Input: 12-48V
, 1A max.
AC I nput: 24V
, 0.6A max .
V1+ V2+
PWR1 PW R2Alarm
2.ProductSpecications
Model IGT-805AT
Hardware Specications
Copper Interface 1 x 10/100/1000BASE-T RJ45 TP
Auto-MDI/MDI-X, auto-negotiation
Fiber Optic
Interface
1 1000BASE-SX/LX/BX SFP interface.
Compatible with 100BASE-FX SFP
Connector
Removable 6-pin terminal block
Pin 1/2 for Power 1, Pin 3/4 for fault alarm,
Pin 5/6 for Power 2
Alarm
Provides one relay output for power failure
Alarm relay current carry ability: 1A @ DC
24V
LED
3 x LED for System and Power:
Green: DC Power 1
Green: DC Power 2
Red: Power Alarm
2 x LED for Per Copper Port:
Green: LNK/ACT
Green:1000 LNK/ACT
1 x LED for Per SFP Interface
Green: LNK/ACT
ESD Protection 6KV DC
Enclosure IP30 type metal case
Installation DIN rail kit and wall mount ear
Dimensions
(W x D x H) 32 x 87 x 135 mm
Network Cables
100BASE-FX:
50/125μm or 62.5/125μm multi-mode
ber optic cable, up to 2 kilometers
(varying on SFP module)
9/125μm single-mode ber optic cable, up
to 20/40/60 kilometers
(varying on SFP module)
Standards Conformance
Standards
Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3ab Gigabit Ethernet
IEEE 802.3z Gigabit Ethernet
IEEE 802.3x full-duplex ow control
Regulatory
Compliance FCC Part 15 Class A, CE
Stability Testing
IEC 60068-2-32 (free fall)
IEC 60068-2-27 (shock)
IEC 60068-2-6 (vibration)
Environment
Temperature Operating: -40~75 degrees C
Storage: -40~75 degrees C
Humidity Operating: 5~95% (non-condensing)
Storage: 5~95% (non-condensing)
Front Panel
P1 P2
LNK/
ACT
LNK/
ACT
1000
Alarm
100/1000X
10/100/1000T
SFP Port
100/1000BASE-X SFP port
for transceiver module,
enabling to have a networking
distance of 550 meters to 2km
(multi-mode ber) and up to
10/20/40/60/80/120 kilometers
(single-mode ber or WDM
ber).
Gigabit TP Interface
10/100/1000BASE-T
copper RJ45 twisted-pair
with up to 100 meters in
distance.
Figure 2: IGT-805AT Front Panel
3.3 Wiring the Power Inputs
The terminal block connector on the top panel of Industrial Gigabit
Media Converter is used for 12~48V DC power inputs. Please follow
the steps below to insert the power wire.
Caution
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
sure the power is OFF to prevent from getting an
electric shock.
1. Insert positive/negative DC power wires into contacts 1 and 2 for
POWER 1, or 5 and 6 for POWER 2.
Max . Fault A larm Lo ading: 24V, 1A
DC Input: 12-48V
, 1A max.
AC Input: 24V
, 0.6A max.
V1+ V2+
PWR1 PWR2Alarm
1 2 3 4 5 6
2. Tighten the wire-clamp screws for preventing the wires from
loosening.
123456
Power 1 Power 2Alarm
+ - + -
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
Note
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. The DC power input range is 12V ~ 48V DC and
supports 24V AC
3. Use one power input when using 24V AC
3.4 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. When inserting the wires,
the Industrial Gigabit Media Converter will detect the fault status
of the power failure and then forms an open circuit. The following
illustration shows an application example for wiring the fault alarm
contacts.
Fault Alarm Contacts
Alarm
1 2 3 4 5 6
The Fault Alarm Contacts are energized
(CLOSE) for normal operation and will
OPEN when failure occurs
Note
1. The wire gauge for the terminal block should be in
the range of 12 ~ 24 AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A
currents.
4.1 DIN-rail Mounting Installation
1
2
4.2 Wall-mount Plate Mounting
4.3 Side Wall-mount Plate Mounting
Caution
You must use the screws supplied with the wall-
mounting brackets. Damage caused to the parts by
using incorrect screws would invalidate your warranty.
3.5 Grounding the Device
Users MUST complete grounding wired with the device; otherwise,
a sudden lightning could cause fatal damage to the device. EMD
(Lightning) DAMAGE IS NOT CONVERED UNDER WARRANTY.
Max . Fault Alar m Loadi ng: 24V, 1A
DC Input: 12-48V
, 1A max.
AC Input: 24V
, 0.6A max.
V1+ V2+
PWR1 PWR2Alarm
1 2 3 4 5 6
Earth Ground
4. Installation
This section describes the functionalities of the Industrial Gigabit
Media Converter’s components and guides how to install it on
the DIN-rail and wall. Basic knowledge of networking is assumed.
Please read this chapter completely before continuing.
Note
This following pictures show the user how to install
the device, and the device is not IGT-805AT.
5. Link Fault Passthrough
The LFP function includes Link Loss Carry Forward (LLCF), Link Loss
Return (LLR) and turned on by chipset default. LLCF and LLR can
immediately alarm administrators the issue of the link media and
provide ecient solution to monitor the net.
IP Camera
LFP
Enabled
LFP
Enabled
Copper Cable Copper Cable
Monitoring Center
IP Camera
Fiber Cable
LFP
Enabled
LFP
Enabled
Copper Cable Copper Cable
Monitoring Center
Copper Link Broken
1
Copper
Link Down
5
LFP disconnects
Fiber Link
2
LFP disconnects
Copper Link
4
Fiber Link Down
3
1000
1000
Fiber Cable
Remote Link
B ro k e n
Remote Link
N o rm al
1000BASE-SX/LX Fiber-optic
1000
1000BASE-T UTP
Note
LFP function is turned on by chipset default and this
feature cannot be turned off. Please assure both TP
and Fiber port connections have established to enable
both TP and Fiber connections to link up.
Customer Support
Thank you for purchasing PLANET products. You can browse our
online FAQ resource on PLANET web site rst to check if it could
solve your issue. If you need more support information, please
contact PLANET switch support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2021.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.


Produktspezifikationen

Marke: Planet
Kategorie: Nicht kategorisiert
Modell: IGT-805AT
Breite: 32 mm
Tiefe: 87 mm
Gewicht: 395 g
Produktfarbe: Blau
Internationale Schutzart (IP-Code): IP30
Übertragungstechnik: Kabelgebunden
Höhe: 135 mm
Betriebstemperatur: -40 - 75 °C
Relative Luftfeuchtigkeit in Betrieb: 5 - 95 %
Zertifizierung: FCC Part 15 Class A, CE
Stromverbrauch (Standardbetrieb): 3.3 W
Anzahl Ethernet-LAN-Anschlüsse (RJ-45): 1
Warentarifnummer (HS): 85176990
Gehäusematerial: Metall
Maximale Datenübertragungsrate: 1000 Mbit/s
Ethernet LAN Datentransferraten: 10,100,1000 Mbit/s
Eingebaut: Nein
LED-Anzeigen: Ja
Temperaturbereich bei Lagerung: -40 - 75 °C
Luftfeuchtigkeit bei Lagerung: 5 - 95 %
Auto MDI/MDI-X: Ja
Eingangsspannung: 12 - 48 V
Maximal mögliche Übertragungsstrecke: 120000 m
Wellenlänge: - nm
Optischer Kabelverbinder: SFP
Anzahl Faseranschlüsse: 1
DIN-Schienen-Montage: Ja
Converter output Oberfläche: 1000Base-BX, 1000Base-LX, 1000Base-SX