Planet GSD-2022P Bedienungsanleitung

Planet Schalten GSD-2022P

Lesen Sie kostenlos die ๐Ÿ“– deutsche Bedienungsanleitung fรผr Planet GSD-2022P (2 Seiten) in der Kategorie Schalten. Dieser Bedienungsanleitung war fรผr 7 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/2
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Package Contents
Thank you for purchasing PLANET 16-Port 10/100/1000T 802.3at PoE+
Ethernet Switch, GSD-2022P. mentioned in โ€œ802.3at PoE+ Switchโ€
this Guide refers to the GSD-2022P.
Open the box of the 802.3at PoE+ Switch and carefully unpack it. The
box should contain the following items:
The 802.3at PoE+ Switch x 1 Userโ€™s Manual x 1 Power Cord x 1
SFP Dust Cap
x 2 Screws x 8 Rack-mounting
Brackets x 2 Rubber Feet x 4
If any of these pieces are missing or damaged, please contact your
dealer immediately; if possible, retain the carton including the original
packing material, and use them again to repack the product in case
there is a need to return it to us for repair.
๏ƒ˜ Hardware-based DIP switch for or mode Standard, VLAN Extend
selection;
โˆ’๎˜ƒ VLAN๎˜ƒmode:๎˜ƒPorts๎˜ƒ1๎˜ƒto๎˜ƒ16๎˜ƒcannot๎˜ƒcommunicate๎˜ƒwith๎˜ƒeach๎˜ƒother,๎˜ƒ
but can communicate with the uplink ports 17 to 18 and SFP
ports 19 to 20
โˆ’๎˜ƒ Extend๎˜ƒ mode:๎˜ƒ Ports๎˜ƒ 1๎˜ƒ to๎˜ƒ 8๎˜ƒ have๎˜ƒ data๎˜ƒ rate๎˜ƒ of๎˜ƒ 10Mbps.๎˜ƒ The๎˜ƒ
farthest transmission distance is up to 250 meters and all ports
can communicate with each other.
๏ƒ˜๎˜ƒ VLAN๎˜ƒ mode๎˜ƒ is๎˜ƒ to๎˜ƒ isolate๎˜ƒ ports๎˜ƒ to๎˜ƒ prevent๎˜ƒ broadcast๎˜ƒ storm๎˜ƒ and๎˜ƒ
defend๎˜ƒDHCP๎˜ƒspoo๎šฟng
๏ƒ˜ Automatic address learning and address aging
๏ƒ˜๎˜ƒ Supports๎˜ƒEnergy-E๎ง’cient๎˜ƒEthernet๎˜ƒ(EEE)๎˜ƒfunction๎˜ƒ(IEEE๎˜ƒ802.3az)
๏ฎ Hardware
๏ƒ˜๎˜ƒ 12-inch๎˜ƒdesktop๎˜ƒsize,๎˜ƒ1U๎˜ƒheight
๏ƒ˜ LED indicators for system power, per port PoE ready and PoE
activity,๎˜ƒspeed,๎˜ƒLink/Act
๏ƒ˜๎˜ƒ 1๎˜ƒsilent๎˜ƒfan๎˜ƒto๎˜ƒprovide๎˜ƒstable๎˜ƒand๎˜ƒe๎ง’cient๎˜ƒpower๎˜ƒperformance
๏ƒ˜๎˜ƒ Supports๎˜ƒ contact๎˜ƒ discharge๎˜ƒof๎˜ƒ ยฑ6KV๎˜ƒ DC๎˜ƒ and๎˜ƒ air๎˜ƒdistance๎˜ƒ discharge๎˜ƒ
of๎˜ƒยฑ8KV๎˜ƒDC๎˜ƒfor๎˜ƒEthernet๎˜ƒESD๎˜ƒprotection
๏ƒ˜๎˜ƒ Supports๎˜ƒยฑ6KV๎˜ƒsurge๎˜ƒimmunity
3.๎˜ƒProduct๎˜ƒSpeci๎šฟcations
Model GSD-2022P
Hardware๎˜ƒSpeci๎šฟcations
10/100/1000BASE-T
Copper Ports 18 auto MDI/MDIX
4.2 LED Indicators
๏ฎ System
LED Color Function
PWR Green Lights to indicate the Switch has power.
๏ฎ Per 10/100/1000BASE-T Port
LED Color Function
10/100/1000
LNK/ACT Green
Lights to indicate the link through that
port is successfully established.
Blinks to indicate that the Switch is
actively๎˜ƒsending๎˜ƒor๎˜ƒreceiving๎˜ƒdata๎˜ƒover๎˜ƒ
that port.
PoE in Use Amber Lights๎˜ƒto๎˜ƒindicate๎˜ƒthe๎˜ƒport๎˜ƒis๎˜ƒproviding๎˜ƒ
PoE DC in-line power.
๏ฎ Per 1000BASE-X SFP Interface
LED Color Function
1000
LNK/ACT Green
Lights to indicate the link through that port
is successfully established at 1000Mbps.
Blinks๎˜ƒto๎˜ƒindicate๎˜ƒthat๎˜ƒthe๎˜ƒSwitch๎˜ƒis๎˜ƒactively๎˜ƒ
sending๎˜ƒor๎˜ƒreceiving๎˜ƒdata๎˜ƒover๎˜ƒthat๎˜ƒport.
Switch
Throughput@64bytes 29.76Mpps
MAC Address Table 8K entries
Jumbo Frame 9216 bytes
Flow Control IEEE 802.3x pause frame for full duplex;
back pressure for half duplex
Power๎˜ƒover๎˜ƒEthernet
PoE Standard IEEE๎˜ƒ802.3at๎˜ƒPower๎˜ƒover๎˜ƒEthernet๎˜ƒPlus/PSE
PoE Injector Ports 16
PoE Power Supply
Type
End-span/Mid-span:๎˜ƒ1/2/4/5๎˜ƒ(+),๎˜ƒ3/6/7/8๎˜ƒ
(-)
PoE Power Output
Per๎˜ƒport๎˜ƒ54V๎˜ƒDC,๎˜ƒ300mA.๎˜ƒmax.๎˜ƒ15.4๎˜ƒwatts๎˜ƒ
(IEEE๎˜ƒ802.3af)
Per๎˜ƒport๎˜ƒ54V๎˜ƒDC,๎˜ƒ600mA.๎˜ƒmax.๎˜ƒ32๎˜ƒwatts๎˜ƒ
(IEEE๎˜ƒ802.3at)
PoE Power Budget 185 watts
Number of PDs, 7
watts 16
Number of PDs, 15.4
watts 12
Number of PDs, 30
watts 6
Standards Conformance
Regulatory
Compliance FCC Part 15 Class A, CE
2. Product Features
๏ฎ Physical Port
๏ƒ˜ 16-port 10/100/1000BASE-T Gigabit RJ45 copper with IEEE
802.3at PoE+ injector function
๏ƒ˜ 2 10/100/1000BASE-T Gigabit RJ45 copper interfaces
๏ƒ˜ 2 1000BASE-X SFP slot interfaces
๏ฎ๎˜ƒ Power๎˜ƒover๎˜ƒEthernet
๏ƒ˜๎˜ƒ Complies๎˜ƒ with๎˜ƒ IEEE๎˜ƒ 802.3at๎˜ƒ Power๎˜ƒ over๎˜ƒ Ethernet๎˜ƒ Plus๎˜ƒ end-span๎˜ƒ
PSE
๏ƒ˜๎˜ƒ Up๎˜ƒ to๎˜ƒ 16๎˜ƒ ports๎˜ƒ of๎˜ƒ IEEE๎˜ƒ 802.3af/802.3at๎˜ƒ devices๎˜ƒ powered๎˜ƒ (ports๎˜ƒ
1~16)
๏ƒ˜ Supports PoE power up to 32 watts for each PoE port, with a total
PoE budget of 185W
๏ƒ˜๎˜ƒ Each๎˜ƒport๎˜ƒsupports๎˜ƒ54V๎˜ƒDC๎˜ƒpower๎˜ƒto๎˜ƒPoE๎˜ƒpowered๎˜ƒdevice
๏ƒ˜๎˜ƒ Auto๎˜ƒdetects๎˜ƒpowered๎˜ƒdevice๎˜ƒ(PD)
๏ƒ˜๎˜ƒ Supports๎˜ƒPD๎˜ƒalive๎˜ƒfunction
๏ƒ˜๎˜ƒ Circuit๎˜ƒprotection๎˜ƒprevents๎˜ƒpower๎˜ƒinterference๎˜ƒbetween๎˜ƒports
๏ƒ˜ Remote power feeding up to 100m in standard mode with 250m in
extend mode
๏ฎ Switching
๏ƒ˜ Hardware-based 10/100/1000Mbps auto-negotiation and auto MDI/
MDI-X
๏ƒ˜๎˜ƒ Supports๎˜ƒ IEEE802.3x๎˜ƒ ๎›€ow๎˜ƒ control๎˜ƒ in๎˜ƒ full-duplex๎˜ƒ mode๎˜ƒ and๎˜ƒ back-
pressure in half-duplex mode
๏ƒ˜ Integrates address look-up engine, supporting 8K absolute MAC
addresses
๏ƒ˜๎˜ƒ 9K๎˜ƒjumbo๎˜ƒframe๎˜ƒsupports๎˜ƒall๎˜ƒspeeds๎˜ƒ(10/100/1000Mbps)
1000BASE-X SFP
Slots 2
DIP Switch
Selectable operation mode
๏ƒ˜ Standard
๏ƒ˜ VLAN
๏ƒ˜ Extend
LED
๏ƒ˜ System:
๎˜ƒ๎˜ƒ๎˜ƒPower๎˜ƒ(Green)
๏ƒ˜ 10/100/1000T RJ45 Interfaces
๎˜ƒ๎˜ƒ๎˜ƒ10/100/1000๎˜ƒLNK/ACT๎˜ƒ(Green),
๎˜ƒ๎˜ƒ๎˜ƒPoE-in-Use๎˜ƒ(Amber)
๏ƒ˜ 1000X SFP Interfaces
๎˜ƒ๎˜ƒ๎˜ƒ1000๎˜ƒLNK/ACT๎˜ƒ(Green)
Dimensions
(W๎˜ƒx๎˜ƒD๎˜ƒx๎˜ƒH) 280๎˜ƒx๎˜ƒ180๎˜ƒx๎˜ƒ44๎˜ƒmm๎˜ƒ(1U๎˜ƒheight)
Enclosure Metal
Weight 1810g
Power Requirements 100~240V๎˜ƒAC,๎˜ƒ50/60Hz,๎˜ƒ5A๎˜ƒmax.
Power Consumption/
Dissipation Max. 201 watts/686 BTU
Thermal Fan 1
ESD Protection Contact๎˜ƒdischarge๎˜ƒof๎˜ƒยฑ6KV๎˜ƒDC,
Air๎˜ƒdischarge๎˜ƒof๎˜ƒยฑ8KV๎˜ƒDC
Surge Protection ยฑ6KV
Installation Desktop or rack-mount installation
Switching
Switch Architecture Store-and-Forward
Switch Fabric 40Gbps/non-blocking
Standards
Compliance
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab Gigabit 1000BASE-T
IEEE๎˜ƒ802.3z๎˜ƒGigabit๎˜ƒSX/LX
IEEE๎˜ƒ802.3x๎˜ƒ๎›€ow๎˜ƒcontrol๎˜ƒand๎˜ƒback๎˜ƒpressure
IEEE๎˜ƒ802.3af๎˜ƒPower๎˜ƒover๎˜ƒEthernet
IEEE๎˜ƒ802.3at๎˜ƒPower๎˜ƒover๎˜ƒEthernet๎˜ƒPlus
IEEE๎˜ƒ802.3az๎˜ƒEnergy-E๎ง’cient๎˜ƒEthernet
Environment
Operating
Temperature: 0 ~ 50 degrees C
Relative๎˜ƒHumidity:๎˜ƒ5~๎˜ƒ95%
(non-condensing)
Storage
Temperature: -10 ~ 70 degrees C
Relative๎˜ƒHumidity:๎˜ƒ5๎˜ƒ~๎˜ƒ95%
(non-condensing)
4. Hardware Introduction
4.1 Front Panel
The Front Panel of the 802.3at PoE+ Switch consists of 18 auto-sensing
10/100/1000Mbps Ethernet RJ45 ports and 2 1000BASE-X SFP slots.
The LED Indicators are also located on the front panel of the 802.3at
PoE+ Switch.
2 106 14 18 20
1 95 13 17 19
PoE Max
PWR
4 128 16
3 117 15
19 20
1000X SFP
Standard
VLAN
Ext end
PoE-in-Us e
LNK
ACT
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
Figure 4-1: GSD-2022P Switch Front Panel
4.3 Multiple Functions of DIP Switch
The๎˜ƒ front๎˜ƒ panel๎˜ƒof๎˜ƒ the๎˜ƒ 802.3at๎˜ƒ PoE+๎˜ƒSwitch๎˜ƒ provides๎˜ƒ one๎˜ƒ DIP๎˜ƒ switch๎˜ƒfor๎˜ƒ
Standard, VLAN or Extend mode selection. The detailed descriptions
are shown in the following table.
DIP Switch Mode Function
Standard
VLAN
Extend
This mode makes the 802.3at PoE+ Switch
operate as a general switch and all PoE
ports operate at 10/100/1000Mbps auto-
negotiation. All ports can communicate with
one another.
Standard
VLAN
Extend
This mode makes the 802.3at PoE+ Switch
operate as a switch andVLAN isolation
1.๎˜ƒ Ports๎˜ƒ1๎˜ƒto๎˜ƒ16๎˜ƒwill๎˜ƒisolate๎˜ƒrespectively.
2. Ports 1 to 16 can only communicate with
ports๎˜ƒ17~18๎˜ƒ(uplink๎˜ƒports)๎˜ƒand๎˜ƒSFP๎˜ƒports๎˜ƒ
19~20
Standard
VLAN
Extend
This mode makes the 802.3at PoE+ Switch
operate as a Long Reach PoE switch and
1. Ports 1 to 8 support farthest transmission
distance of up to 250 meters
2.๎˜ƒ Ports๎˜ƒ1๎˜ƒto๎˜ƒ8๎˜ƒhave๎˜ƒa๎˜ƒdata๎˜ƒrate๎˜ƒof๎˜ƒ10Mbps
3. All ports can communicate with one
another.
Note
Please adjust the DIP switch before powering on the
802.3at PoE+ Switch.
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
Standard Mode (default)
Power
PoE IP Camera
PoE
100 meters (328 feet)
PoE
100BASE-TX UTP with PoE
GSD-2022P
Standard
VLAN
Extend
VLAN Isolation Mode
NVR
PC
Ports 1 to 16
Access Denied
PoE
PoE
PoE
PoE
100BASE-TX UTP with PoE
GSD-2022P
IP Camera
IP Camera
IP Camera
Ports 17~18 and SFP Ports 19~20
to Ports 1~16 Access Permitted
1000BASE-T UTP
Standard
VLAN
Extend
Extend Mode
Ports 1 to 8
Power
250 meters (820 feet)
PoE
PoE
10BASE-T UTP with PoE
PoE IP Camera
GSD-2022P
Standard
VLAN
Extend
5. Hardware Installation
5.1 Rack Mounting
To install the 802.3at PoE+ Switch in a 19-inch standard rack, follow the
instructions described below.
Step 1:๎˜ƒ Place๎˜ƒ your๎˜ƒ 802.3at๎˜ƒ PoE+๎˜ƒ Switch๎˜ƒ on๎˜ƒ a๎˜ƒ hard๎˜ƒ ๎›€at๎˜ƒ surface,๎˜ƒ with๎˜ƒ
the front panel positioned towards your front side.
Step 2: Attach a rack-mount bracket to each side of the 802.3at PoE+
Switch with supplied screws attached to the package. Figure
5-1 shows how to attach brackets to one side of the 802.3at
PoE+ Switch.
210
614 18 20
19
513 17 19
PoE Max
PW R
4 12
816
311
715
19 20
100
0X S FP
Standa rd
VLA N
Ex
tend
PoE-in-Use
LNK
ACT
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
Figure 5-1: Attaching the Brackets to the 802.3at PoE+ Switch.
Caution
You must use the screws supplied with the mounting
brackets. Damage caused to the parts by using incorrect
screws๎˜ƒwould๎˜ƒinvalidate๎˜ƒthe๎˜ƒwarranty.
Step 3: Secure the brackets tightly.
Step 4: Follow the same steps to attach the second bracket to the
opposite side.
4.4 Rear Panel
The rear panel of the 802.3at PoE+ Switch indicates an AC power
socket,๎˜ƒwhich๎˜ƒaccepts๎˜ƒinput๎˜ƒpower๎˜ƒfrom๎˜ƒ100๎˜ƒto๎˜ƒ240V๎˜ƒAC,๎˜ƒ50-60Hz,๎˜ƒ5A.
50/60Hz
100-240V , 5A max.
Figure 4-2: GSD-2022P Switch Rear Panel
๏ฎ AC Power Receptacle
Power
Notice
The๎˜ƒ device๎˜ƒ is๎˜ƒ a๎˜ƒ power-required๎˜ƒ device,๎˜ƒ which๎˜ƒ means๎˜ƒ
it will not work till it is powered. If your networks
should๎˜ƒ be๎˜ƒ active๎˜ƒ all๎˜ƒ the๎˜ƒ time,๎˜ƒ please๎˜ƒ consider๎˜ƒ using๎˜ƒ UPS๎˜ƒ
(Uninterrupted๎˜ƒ Power๎˜ƒ Supply)๎˜ƒ for๎˜ƒ your๎˜ƒ device.๎˜ƒ It๎˜ƒ will๎˜ƒ
prevent๎˜ƒyou๎˜ƒfrom๎˜ƒnetwork๎˜ƒdata๎˜ƒloss๎˜ƒor๎˜ƒnetwork๎˜ƒdowntime.
Power
Notice
In๎˜ƒ some๎˜ƒ areas,๎˜ƒ installing๎˜ƒ a๎˜ƒ surge๎˜ƒ suppression๎˜ƒ device๎˜ƒ may๎˜ƒ
also help to protect your 802.3at PoE+ Switch from being
damaged by unregulated surge or current to the 802.3at
PoE+ Switch or the power adapter.
Step 5: After the brackets are attached to the 802.3at PoE+ Switch,
use suitable screws to securely attach the brackets to the
rack, as shown in Figure 5-2.
2106 14 18
20
1 9
513 17
19
PoE Max
PW R
412
816
31
1
715
19 20
100
0X SFP
Stan dard
VLA N
Ext end Po E-in -Use
LN
K
ACT
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
Figure 5-2: Mounting the 802.3at PoE+ Switch in a Rack
Step 6: Connect your 802.3at PoE+ Switch to 802.3af/802.3at
complied๎˜ƒPDs๎˜ƒand๎˜ƒother๎˜ƒnetwork๎˜ƒdevices.
A. Connect one end of a standard network cable to the
10/100/1000BASE-T RJ45 ports on the front panel of the 802.3at
PoE+ Switch.
B.๎˜ƒ Connect๎˜ƒ the๎˜ƒother๎˜ƒend๎˜ƒof๎˜ƒ the๎˜ƒcable๎˜ƒ to๎˜ƒthe๎˜ƒnetwork๎˜ƒdevices๎˜ƒ such๎˜ƒas๎˜ƒ
printer๎˜ƒservers,๎˜ƒworkstations๎˜ƒor๎˜ƒrouters,๎˜ƒetc.
Step 7: Supply power to the 802.3at PoE+ Switch.
A. Connect one end of the power cable to the 802.3at PoE+ Switch.
B. Connect the power plug of the power cable to a standard wall
outlet.
When๎˜ƒ the๎˜ƒ 802.3at๎˜ƒ PoE+๎˜ƒ Switch๎˜ƒ receives๎˜ƒ power,๎˜ƒ the๎˜ƒ power๎˜ƒ LED๎˜ƒ should๎˜ƒ
remain solid Green.
5.2 Installing the SFP Transceiver
The๎˜ƒ sections๎˜ƒ describe๎˜ƒ how๎˜ƒ to๎˜ƒ insert๎˜ƒ an๎˜ƒ SFP๎˜ƒ transceiver๎˜ƒ into๎˜ƒ an๎˜ƒ SFP๎˜ƒ slot๎˜ƒ
of the 802.3at PoE+ Switch.
The๎˜ƒSFP๎˜ƒtransceivers๎˜ƒare๎˜ƒhot-pluggable๎˜ƒand๎˜ƒhot-swappable.๎˜ƒYou๎˜ƒcan๎˜ƒplug๎˜ƒ
in๎˜ƒand๎˜ƒout๎˜ƒthe๎˜ƒtransceiver๎˜ƒto/from๎˜ƒany๎˜ƒSFP๎˜ƒport๎˜ƒwithout๎˜ƒhaving๎˜ƒ to๎˜ƒpower๎˜ƒ
down the 802.3at PoE+ Switch, as the Figure 5-3 shows.
MGB-Series
SFP Transceiver
LC Fiber Cable
1
2
Figure 5-3: Plug In the SFP Transceiver
๏ฎ Approved PLANET SFP Transceivers
PLANET 802.3at PoE+ Switch supports both single mode and multi-
mode๎˜ƒ SFP๎˜ƒ transceivers.๎˜ƒ The๎˜ƒ website๎˜ƒ link๎˜ƒ of๎˜ƒ approved๎˜ƒ PLANET๎˜ƒ SFP๎˜ƒ
transceivers๎˜ƒis๎˜ƒshown๎˜ƒbelow:
https://www.planet.com.tw/en/product/mgb-series-transceiver
Note
It is recommended to use PLANET SFP on the 802.3at
PoE+๎˜ƒ Switch.๎˜ƒ If๎˜ƒ you๎˜ƒ insert๎˜ƒ an๎˜ƒ SFP๎˜ƒ trans-ceiver๎˜ƒ that๎˜ƒ is๎˜ƒ not๎˜ƒ
supported,๎˜ƒthe๎˜ƒ802.3at๎˜ƒPoE+๎˜ƒSwitch๎˜ƒwill๎˜ƒnot๎˜ƒrecognize๎˜ƒit.
1. Before we connect the 802.3at PoE+ Switch to the other network
device,๎˜ƒ we๎˜ƒ have๎˜ƒto๎˜ƒ make๎˜ƒ sure๎˜ƒ both๎˜ƒsides๎˜ƒ of๎˜ƒthe๎˜ƒ SFP๎˜ƒ transceivers๎˜ƒ are๎˜ƒ
with the same media type, for example, 1000BASE-SX to 1000BASE-
SX; 1000BASE-LX to 1000BASE-LX.
2.๎˜ƒCheck๎˜ƒ whether๎˜ƒthe๎˜ƒ๎šฟber-optic๎˜ƒ cable๎˜ƒtype๎˜ƒmatches๎˜ƒ with๎˜ƒthe๎˜ƒSFP๎˜ƒ trans-
ceiver๎˜ƒrequirement.
๏ƒ˜๎˜ƒTo๎˜ƒ connect๎˜ƒ to๎˜ƒ 1000BASE-SX๎˜ƒ SFP๎˜ƒ transceiver,๎˜ƒ please๎˜ƒ use๎˜ƒ the๎˜ƒ
multi-mode๎˜ƒ ๎šฟber๎˜ƒ cable๎˜ƒ with๎˜ƒ one๎˜ƒ side๎˜ƒ being๎˜ƒ the๎˜ƒ male๎˜ƒ duplex๎˜ƒ LC๎˜ƒ
connector type.
๏ƒ˜๎˜ƒTo๎˜ƒ connect๎˜ƒ to๎˜ƒ 1000BASE-LX๎˜ƒ SFP๎˜ƒ transceiver,๎˜ƒ please๎˜ƒ use๎˜ƒ the๎˜ƒ
single-mode๎˜ƒ ๎šฟber๎˜ƒ cable๎˜ƒ with๎˜ƒ one๎˜ƒ side๎˜ƒ being๎˜ƒ the๎˜ƒ male๎˜ƒ duplex๎˜ƒ LC๎˜ƒ
connector type.
Customer Support
Thank you for purchasing PLANET products. You can browse our online
FAQ๎˜ƒ resource๎˜ƒ on๎˜ƒ PLANET๎˜ƒ Web๎˜ƒ site๎˜ƒ ๎šฟrst๎˜ƒ to๎˜ƒ check๎˜ƒ if๎˜ƒ it๎˜ƒ could๎˜ƒ solve๎˜ƒ your๎˜ƒ
issue. If you need more support information, please contact PLANET
support team.
PLANET online FAQs:
https://www.planet.com.tw/en/support/faq
Support team mail address
support@planet.com.tw
Copyright ยฉ PLANET Technology Corp. 2020
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.


Produktspezifikationen

Marke: Planet
Kategorie: Schalten
Modell: GSD-2022P

Brauchst du Hilfe?

Wenn Sie Hilfe mit Planet GSD-2022P benรถtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schalten Planet

Bedienungsanleitung Schalten

Neueste Bedienungsanleitung fรผr -Kategorien-