User manual
DreamStation CPAP
DreamStation CPAP Pro
DreamStation Auto CPAP
© 2015 Koninklijke Philips N.V. All rights reserved.
Table of Contents
Intended Use ........................................................................................................................................................... 1
Important ................................................................................................................................................................. 1
Warnings .................................................................................................................................................................. 1
Cautions ................................................................................................................................................................... 2
Contraindications .................................................................................................................................................. 2
Symbol Key ..............................................................................................................................................................3
System Contents .................................................................................................................................................... 3
How to Contact Philips Respironics ................................................................................................................. 3
System Overview ................................................................................................................................................... 4
Installing/Replacing the Air Filters ......................................................................................................................5
Where to Place the Device .................................................................................................................................6
Supplying AC Power to the Device .................................................................................................................... 6
Connecting the Breathing Circuit ...................................................................................................................... 7
Navigating the Device Screens ............................................................................................................................8
Starting the Device ................................................................................................................................................8
Menu Navigation (Therapy ON) and Optional Humidication Settings ...................................................9
Ramp Feature .......................................................................................................................................................... 9
Menu Navigation (Therapy OFF) ......................................................................................................................10
Bluetooth® Wireless Technology .........................................................................................................................14
Check Mask Fit .....................................................................................................................................................15
Sleep Progress ......................................................................................................................................................15
Altitude Compensation ......................................................................................................................................15
Device Alerts ........................................................................................................................................................16
Troubleshooting ...................................................................................................................................................20
Accessories ...........................................................................................................................................................22
Traveling with the System ..................................................................................................................................23
Cleaning the Device ............................................................................................................................................24
Cleaning or Replacing the Filters .....................................................................................................................24
Cleaning the Tubing ..............................................................................................................................................24
Service ....................................................................................................................................................................24
Additional Notices ...............................................................................................................................................25
Specications ........................................................................................................................................................26
Disposal ..................................................................................................................................................................27
EMC Information .................................................................................................................................................27
Limited Warranty ...................................................................................................................................Back Page
1User Manual
Caution: U. S. federal law restricts this device to sale by or on the order of a physician.
Intended Use
The Philips Respironics DreamStation systems deliver positive airway pressure therapy for the treatment of Obstructive Sleep Apnea in
spontaneously breathing patients weighing over 30 kg (66 lbs). It is for use in the home or hospital/institutional environment.
Important
The device is to be used only on the instruction of a licensed physician. Your home care provider will make the correct pressure
settings and device congurations including accessories according to your health care proessionals prescription
Several accessories are available to make your OSA treatment with the DreamStation system as convenient and comfortable as
possile To ensure that you receive the sae eective therapy prescried or you use only hilips espironics accessories
Warnings
A warning indicates the possibility of injury to the user or the operator.
This manual serves as a reerence The instructions in this manual are not intended to supersede the health care proessionals
instructions regarding the use of the device.
The operator should read and understand this entire manual eore using the device
This device is not intended or lie support
ended y hilips espironics or ith those recommended y the The device should e used only ith mass and connectors recomm
health care professional or respiratory therapist. A mask should not be used unless the device is turned on and operating properly.
The exhalation port(s) associated with the mask should never be blocked. The device is intended Explanation of the Warning:
to e used ith special mass or connectors that have ehalation ports to allo continuouso o air out o the mas hen
the device is turned on and unctioning properly ne air rom the device ushes the ehaled air out through the mas ehalation
port Hoever hen the device is not operating enough resh air ill not e provided through the mas and ehaled air may e
rebreathed. Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation.
 you are using a ull ace mas (a mas covering oth your mouth and your nose) the mas must e euipped ith a saety
(entrainment) valve.
hen using oygen ith this system the oygen supply must comply ith local regulations or medical oygen
Oygen supports comustion Oygen should not e used hile smoing or in the presence o an open ame
hen using oygen ith this system turn the device on eore turning on the oygen Turn the oygen o eore turning the
device off. This will prevent oxygen accumulation in the device. Explanation of the Warning: hen the device is not in
operation and the oygen o is let on oygen delivered into the tuing may accumulate ithin the devices enclosure Oygen
accumulated in the device enclosure ill create a ris o re
hen using oygen ith this system a hilips espironics ressure alve must e placed inline ith the patient circuit eteen
the device and the oygen source The pressure valve helps prevent the aco o oygen rom the patient circuit into the
device hen the unit is o ailure to use the pressure valve could result in a re haard
o not connect the device to an unregulated or high pressure oygen source
o not use the device in the presence o a ammale anaesthetic miture in comination ith oygen or air or in the presence
of nitrous oxide.
o not use the device near a source o toic or harmul vapors
  ( )  the device is used at room temperaturesarmer o not use this device i the room temperature is armer than 
than ( ) the temperature o the airo may eceed   ( ) This could cause irritation or inury to your airay
o not operate the device in direct sunlight or near a heating appliance ecause these conditions can increase the temperature o
the air coming out of the device.
ontact your health care proessional i symptoms o sleep apnea recur
 you notice any uneplained changes in the perormance o this device i it is maing unusual or harsh sounds i it has een
dropped or mishandled i ater is spilled into the enclosure or i the enclosure is roen disconnect the poer cord and
discontinue use ontact your home care provider
epairs and adustments must e perormed y hilips espironicsauthoried service personnel only nauthoried service could
cause inury invalidate the arranty or result in costly damage
o not use any accessories detachale parts and materials not recommended y hilips espironics ncompatile parts or
accessories can result in degraded performance.
se only approved cales and accessories Misuse may aect M perormance and should e avoided
The Health ndustry Manuacturers ssociation recommends that a minimum separation o si inches e maintained eteen
a ireless phone and a pacemaer to avoid potential intererence ith the pacemaer The reamStation onoard Bluetooth
communication should be considered a wireless phone in this regard.
ay cause se only poer cords supplied y hilips espironics or this devicese opoer cords not suppliedy hilips espironics m
overheating or damage to the device and may result in increased emissions or decreased immunity o the euipment or system
The device should not e used hile staced or in close approimation to other nonapproved devices
o not pull or stretch the tuing This could result in circuit leas


Produktspezifikationen

Marke: Philips
Kategorie: Nicht kategorisiert
Modell: DreamStation Auto CPAP

Brauchst du Hilfe?

Wenn Sie Hilfe mit Philips DreamStation Auto CPAP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Philips

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-