Perfect Aire PAU16 Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Perfect Aire PAU16 (12 Seiten) in der Kategorie Luchtbevochtiger. Dieser Bedienungsanleitung war für 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
ULTRASONIC COOL MIST
HUMIDIFIER
FOR MODEL:
PAU16
Before using your ultrasonic humidifie , please r
read this manual carefully and keep it for
future reference, along with your receipt.
USER MANUAL
CONTENTS
Safety Guidelines ..................................................... 2..
Technical Data............................................................. 3
Features....................................................................... 3
Parts Diagram ............................................................. 3
Humidifier Set Up ...................................................... 4
Operating Instructions.............................................. 4-5
Maintenance Instructions ......................................... 5-6
Storage Instructions .................................................... 6
Warranty ...................................................................... 8
Troubleshooting .......................................................... 7
1
2
SAFETY GUIDELINES
When using any electrical appliances, basic safety precautions should always be followed. Failure to follow these safety precautions may result
in personal injury, property damage, fire or shock
.
1. There must be water in the tank when operating the unit.
2. We recommend using only filtered or distilled water. Using tap water with a high mineral content (hard water) will result in a white
dust and the need for more frequent cleanings. Hard water can damage the nebulizer and may eventually cause it to fail.
3. Be sure the cap is firmly fastened onto the tank.
4. Position the unit so the mist control output nozzle is aimed away from children, walls and furniture in the room (min. 36 in/91 cm
clearance) to avoid condensation and property damage.
5. When removing the tank, grasp it firmly with both hands, before using one hand to support the bottom.
6. DO NOT use this unit if the tank is cracked.
7. DO NOT place the near heat sources such as a stove, oven, or direct sunlight. Keep the cord away from hot surfaces and humidifier
areas where it can be stepped on or tripped over.
8. Use only a dedicated, grounded 120V AC outlet, making sure the unit is plugged in firmly and completely. Plug and unplug the unit
with dry hands only.
9. Turn off and unplug the unit when moving or cleaning it, or when it's not in use.
10. T
o avoid the risk of fire, shock, or personal injury, do not use an extension cord or power strip.
Warning
Warning
Warning
WarningWarning: Never operate the unit with a
damaged cord or plug.
11. DO NOT place on the floor or carpet. Always place the unit on a flat, level, waterproof surface at least 24 in. (61 cm) off the floor
AWAY from direct sunlight, computers or other sensitive electronics.
12.
DO NOT place the humidifier on wood furniture or other surfaces that can be damaged by water.
13. DO NOT place the unit on towels or soft surfaces. This will block the air vent and cause overheating.
14. DO NOT add medicine, essential oils, or cleaning products of any type into the mist control nozzle, base or water tank (See the
“Weekly Maintenance Cleaning & Care” section for proper instructions). NEVER cover or block any openings on the unit. cleaning
NEVER drop or insert any objects into any openings.
15. The unit should not be left unattended in closed rooms as air could become too humid leave condensation on the walls or and
furniture. Always leave a door partially open.
16. DANGER: NEVER immerse the humidifier base (motor unit) in water or other liquids as electrical shock may occur.
17. DO NOT use the unit outdoors.
18. Turn the humidifier OFF if the relative humidity exceeds 60% or if you notice condensation on the windows. For a proper humidity
reading, use a hygrometer which is available in many retail stores.
19. The nebulizer (ultrasonic transducer) is highly sensitive. Keep this important part clean and treat it gently. Clean only according to the
instructions on page 7.
WARNING
WARNING
WARNING
WARNINGWARNING: Do not touch the nebulizer while the unit is operating, as possible burns could result.
Do not touch the nebulizer with fingers. Any residue on the metal will reduce mist output.
20. The unit contains no user serviceable parts. To reduce the risk of electrical shock, do no attempt to open the base of humidifier.
DANGER! To reduce the risk of electrical shock, this product has a polarized plug (one blade is wider than the other). As a safety
feature this plug will fit into the outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact
a qualified electrician. DO NOT attempt to bypass this safety feature. Improper use of electric cords and plugs can cause a fire or electric
shock hazard. NEVER pull on the cord to remove the plug from the outlet. Grip the plug and pull directly from the outlet. Check the power
cord and plug for damage. If the cord or plug are damaged, contact Customer Service before using the humidifier.

Produktspezifikationen

Marke: Perfect Aire
Kategorie: Luchtbevochtiger
Modell: PAU16

Brauchst du Hilfe?

Wenn Sie Hilfe mit Perfect Aire PAU16 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Luchtbevochtiger Perfect Aire

Bedienungsanleitung Luchtbevochtiger

Neueste Bedienungsanleitung für -Kategorien-