Energy Efficient
Data Center
Cabinet Systems
For more information about Cisco Compatible Solutions visit
https://marketplace.cisco.com/catalog and search Panduit.
Using the Panduit Energy
Ef cient Data Center Cabinet
System, you can greatly
improve the energy ef ciency
of your data center while
con dently increasing
your kW per cabinet density
to increase utilization of your
data center space.
Factors Effecting Ef ciency
• Inlet temperatures
• ΔT across heat exchanger
• Capacity utilization
Ef ciency In uencers
• Inlet temperatures
• Set points
• Hot air/cold air leakage and recirculation
• Server/CRAH fan speeds
• kW per cabinet density
Enabling Improved Ef ciency
• Seal every gap for complete separation
of cooling and exhaust air
• Direct cold air to where it needs to go
• Contain cooling and exhaust air for
maximum cooling capacity ef ciency
• Monitor to maintain operational and
energy ef ciency
Reduce Operational Costs, Improve
Capacity Utilization, and Lower
Power Usage Effectiveness (PUE)*
Driven by explosive data processing growth, Data Center Managers face multiple, competing
demands: reducing operational costs, improving energy ef ciency, and optimizing available
capacity, while sustaining a low total cost of ownership.
To meet these demands while minimizing the risk to service levels, the available data center
space is often underutilized while being overprovisioned with excess power and cooling capacity
regardless of actual IT equipment and space utilization. Today, a typical data center consumes
about 3-5kW per cabinet due to power and cooling concerns, while the available cabinet space
can accommodate 15kW or more per cabinet if managed effectively.
As energy and construction costs continue to rise, over-provisioning and under-utilization are no
longer sustainable. Energy costs related to cooling account for approximately 37% of the overall
data center power consumption1 and are one of the fastest rising data center operational costs
2.
2visit www.panduit.com/Cabinets
Average data center energy usage allocation
1
IT
Equipment
50%
Lighting
Etc.,
3%
Electricity
Transformer
UPS 10%
Air
Movement
12%
Cooling
25%
*Power Usage Effectiveness – a metric used to measure how effectively input power is used. It is expressed as a ratio of
power available to power used.
1 Average Data Center Energy Usage Allocation , Lawrence Berkeley National Laboratory 2007
2 451 Research has published 'Highly Energy-Ef cient Datacenters in Practice,' October 2012
3
visit www.panduit.com/Cabinets
Power and cooling capacity remain the top targets for ef ciency improvement and optimization of
cooling capacity is often the simplest way for data center operators to realize short term savings
and directly impact PUE3.
Panduit Labs research con rms that raising the supply air temperature in a data center is one of
the most effective means to reduce energy consumption. In addition, higher return temperatures
enable a higher CRAH ΔT across the heat exchangers allowing the cooling system to operate
more ef ciently.
A key way to realize this energy ef ciency potential and enable maximum capacity utilization is to
eliminate the mixing of cold and hot air within the cabinet and at the room level delivering higher
return air temperatures to the cooling system and allowing higher room set points.
1°C rise in chiller water temperature translates into
3-4% cooling system energy savings
4
.
3 How To Measure Energy Consumption In Your Data Center, Gartner Core RAS Research Note G00205428, 8 September 2010
4 Design Considerations for Datacom Equipment Centers ASHRAE 2005, ISBN 1-931862-94-X. Page 138

Produktspezifikationen

Marke: Panduit
Kategorie: Nicht kategorisiert
Modell: TLBP1R-V
Breite: 483 mm
Tiefe: 51 mm
Produktfarbe: Schwarz
Höhe: 45 mm
Menge pro Packung: 5 Stück(e)
Größe (Imperial): 19 "
Nachhaltigkeitszertifikate: RoHS
Rack-Kapazität: 1U

Brauchst du Hilfe?

Wenn Sie Hilfe mit Panduit TLBP1R-V benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Panduit

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-