For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
D1.89
B2.
Cable
Accessories
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
F.
Index
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
E5.
Lockout/
Tagout
& Safety
Solutions
B1.
Cable Ties
A.
System
Overview
D3.
Grounding
Connectors
E4.
Permanent
Identification
Tooling Selection Guide for
PANDUIT
Terminals, Splices, and Disconnects
Table continues on page D1.90
PANDUIT
Terminal
Series
Terminal
Description
Std.
Wire
Range
(AWG)
Wire
Strip
Length
(In.)
[+1/32;-0]
Plier Tools Controlled Cycle Hand Tools
Crimp Heads
for Pneumatic
CT-600-A Tool
CT-100A
CT-160
CT-200
CT-260
CT-300-1
CT-310
CT-400
CT-460
CT-1014
CT-1015
CT-1525
CT-1550
CT-1551
CT-1570
CT-1701
CT-2500
CT-500CH
CT-520CH
CT-550CH
CT-570CH
CT-720
BS Non-insulated
butt splices
26 – 22 1/4 X X
22 – 18 9/32 X X X X X X X
16 – 14 9/32 X X X X X X X
12 – 10 9/32 X X X X X XX X
BSH Heat shrink splices 22 – 18 5/16 X
16 – 14 5/16 X
12 – 10 5/16 X
BSN Nylon insulated
butt splices
26 – 22 1/4 X X
22 – 18 9/32 X X X X X X X
16 – 14 9/32 X X X XX X X X X
12 – 10 9/32 X X X X X X X X
BSV Vinyl insulated
butt splices
22 – 18 5/16 X X X X X X X X X
16 – 14 5/16 X X X XX X X X X X
12 – 10 5/16 X X X X X X X X
D,
DR
Non-insulated
sleeved barrel
disconnects
(includes right
angle disconnect)
22 – 18 9/32 X X X X X X X
16 – 14 9/32 X X X X X X X
12 – 10 9/32 X X X X X XX X
D-M Non-insulated male
blade adapters
22 – 18 9/32 X X X X X X X
16 – 14 9/32 X X X X X X X
D-M Non-insulated
male disconnect
12 – 10 9/32 X X XX X X X
D-MB,
DR-B
Non-insulated right
angle female disc.
and non-insulated
male butted
seam disc.
22 – 18 9/32 X X X X
16 – 14 9/32 X X X X
DNF Nylon, funnel entry,
barrel insulated
disconnect
(not .110/.111)
22 – 18 9/32 X X X X X X
16 – 14 9/32 X X X X X X XX X
DNF-110,
DNF-111
Nylon, funnel entry
barrel insulated
disconnect,
.110/.111 tab size
22 – 18 7/32 X X X X X
16 – 14 9/32 X X X X
DNF-FI Nylon, fully
insulated
disconnect
22 – 18 9/32 X X X XX X X X X
16 – 14 9/32 X X X X X X X X
12 – 10 3/8 X X X X X X X X
DPF-FI Premium nylon,
fully insulated
disconnect
12 – 10 3/8 X X X X X X X X
DNF-FIB,
DNF-FIM,
DNF-FIMB,
DPF-FIB,
DPF-FIMB,
DNF-LPB,
DPF-LPB
Nylon and premium
grade nylon, fully
insulated, funnel
entry, male/female
couplers
(not .110/.111)
22 – 18 9/32 X X X X
16 – 14 9/32 X X X X
12 – 10 3/8 X X
DNF-FIB,
DPF-FIB
Nylon and premium
grade nylon, fully
insulated, funnel
entry disconnect,
110/.111 tab size
22 – 18 7/32 X X X X
DNF-FIBX Nylon, expanded
wire entry
fully insulated
22 – 18 X-9/32 X X
16 – 14 X-9/32 X
Mechanical
Tool/product approved combinations indicated on individual product pages.
ELECTRICAL SOLUTIONS
Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.
D1.90
B2.
Cable
Accessories
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
F.
Index
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
E5.
Lockout/
Tagout
& Safety
Solutions
B1.
Cable Ties
A.
System
Overview
D3.
Grounding
Connectors
E4.
Permanent
Identification
Tooling Selection Guide for
PANDUIT
Terminals, Splices, and Disconnects (continued)
CT-520CH
PANDUIT
Terminal
Series
Terminal
Description
Std.
Wire
Range
(AWG)
Wire
Strip
Length
(In.)
[+1/32;-0]
Plier Tools Controlled Cycle Hand Tools
Crimp Heads
for Pneumatic
CT-600-A Tool
CT-100A
CT-160
CT-200
CT-260
CT-300-1
CT-310
CT-400
CT-460
CT-1014
CT-1015
CT-1525
CT-1550
CT-1551
CT-1570
CT-1701
CT-500CH
DNF-M Nylon insulated,
funnel entry,
barrel insulated,
male disconnects
22 – 18 9/32 X X X X X XX X
16 – 14 9/32 X X X X X XX X
12 – 10 9/32 X X X X X X XX
DNFR-B Nylon
pre-insulated, right
angle disconnects
22 – 18 9/32 X X
16 – 14 9/32 X X
DNFR-FIB Nylon butted
seam, right
angle disconnects
22 – 18 11/32 X
16 – 14 11/32 X
DNG-FB
SUPRA GRIP
β„’nylon,
fully insulated
disc., (except
DNG14-187FB and
DNG14-188FB)
22 – 18 1/4 X
16 – 14 1/4 X
DNG-FL
DISCO -LOK
β„’nylon,
fully insulated
disconnects
22 – 18 1/4 X
16 – 14 1/4 X
DNH Heat
shrink disconnects
22 – 18 5/16 X
16 – 14 5/16 X
12 – 10 5/16 X
DV Vinyl barrel insulated
sleeved disconnects
12 – 10 9/32 X X X XX
DV-B Vinyl
insulated, butted
seam disconnects
22 – 18 1/4 X X XX
16 – 14 1/4 X X XX
DV-M Vinyl barrel insulated
male blade adapters
22 – 18 9/32 X X X X X X XX X
16 – 14 9/32 X X X XX X X XX X
DV-M Vinyl insulated
male disconnects
12 – 10 9/32 X X X
DV-MB Vinyl insulated
butted seam male
disconnects
22 – 18 9/32 X X X XX X
16 – 14 9/32 X XX X XX X
DV-P Vinyl insulated
piggyback
disconnects
22 – 18 1/4 X X X X X XX X
16 – 14 1/4 X X X X X XX X
DVF Vinyl funnel entry
barrel insulated
female disconnect
22 – 18 9/32 X X XX X
16 – 14 9/32 X X XX X
JNon-insulated
wire joints
J214-312 14 – 12 1/2 X X
J318-412 18 – 12 1/2 X X
J216-410 16 – 10 3/4 X
JN Nylon insulated
wire joints
JN224-318 24 – 16 7/16 X X X X X XX X
JN218-216 22 – 16 7/16 X X X X XX X
JN418-212 18 – 12 1/2 X X X X XX
JN314-412 14 – 12 5/8 X
P-HDR Non-insulated heavy
duty rings
16 – 12 9/32 X X XX X XX
P-P Non-insulated
pin terminals
22 – 18 9/32 X X X X X XX
16 – 14 9/32 X X X X X XX
12 – 10 9/32 X X X X X X XX
P-R Non-insulated large
ring terminals
8 3/8 X
6 7/16 X
4 1/2 X
2 1/2 X
CT-570CH
CT-2500
CT-550CH
CT-720
Mechanical
Tool/product approved combinations indicated on individual product pages.
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
ELECTRICAL SOLUTIONS
D1.91
B2.
Cable
Accessories
C1.
Wiring
Duct
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
F.
Index
B3.
Stainless
Steel Ties
C2.
Surface
Raceway
E5.
Lockout/
Tagout
& Safety
Solutions
B1.
Cable Ties
A.
System
Overview
D3.
Grounding
Connectors
E4.
Permanent
Identification
Tooling Selection Guide for
PANDUIT
Terminals, Splices, and Disconnects (continued)
β– 
KYNAR is a registered trademark of Atonfina Chemicals, Inc.
‑Use Die CD-720PV8-2.
PANDUIT
Terminal
Series Terminal Description
Std.
Wire
Range
(AWG)
Wire
Strip
Length
(In.)
[+1/32;-0]
Plier Tools Controlled Cycle Hand Tools
Crimp Heads
for Pneumatic
CT-600-A Tool
CT-100A
CT-160
CT-200
CT-260
CT-300-1
CT-310
CT-400
CT-460
CT-1014
CT-1015
CT-1525
CT-1550
CT-1551
CT-1570
CT-1701
CT-2500
CT-500CH
CT-520CH
CT-550CH
CT-570CH
P-R,
P-F,
P-LF,
P-SLF,
P-FF
Non-insulated rings,
forks, locking forks,
short locking forks,
flanged forks
26 – 22 3/16 X X X
22 – 18 7/32 X X X X X X X
16 – 14 7/32 X X X X X X X
12 – 10 9/32 X X X X X XX X
P-RHT6 High temperature rings 22 – 18 9/32 X X X X X X X
16 – 14 9/32 X X X X X X X
12 – 10 9/32 X X X X X XX X
PH Heat shrink terminals 22 – 18 5/16 X
16 – 14 5/16 X
12 – 10 5/16 X
PN-R,
PN-RX,
PN-F,
PN-LF,
PN-FF,
PNF-R,
PNF-F,
PNF-LF
Nylon and nylon
funnel entry forks,
locking forks, flanged
forks (includes
expanded insulation)
26 – 22 3/16 X X X
22 – 18 7/32 X X X X X X X
16 – 14 7/32 X X X X X XX X
12 – 10 9/32 X X X X X X
PN-HDR,
PN-HDRX
Nylon insulated heavy
duty and nylon
expanded insulated
heavy duty rings
16 – 12 9/32 X X X X X
PN-SLF,
PNF-SLF
Nylon insulated short
locking forks
22 – 18 7/32 X X X X X X
16 – 14 7/32 X X X X X X X
12 – 10 9/32 X X X X X
PS Non-insulated
parallel splices
22 – 18 5/16 X X X
20 – 16 5/16 X X X
14 – 12 7/16 X X X
PSN Nylon insulated
parallel splices
22 – 18 5/16 X X X
20 – 16 5/16 X X X X X X
14 – 12 7/16 X X X
PK-R KYNARβ– rings 22 – 18 7/32 X X X X X X X X
16 – 14 7/32 X X X X X X X X
12 – 10 9/32 X X X X X
PV-HDR,
PV-HDRX
Vinyl insulated heavy
duty rings
16 – 12 5/16 X X X X X
PV-LF,
PV-LFX
Vinyl insulated locking
forks (includes
expanded insulation)
22 – 18 5/16 X X X X X X X X
16 – 14 5/16 X X X X X XX X
12 – 10 5/16 X X X X X X X
PV-P Vinyl insulated
pin terminals
22 – 18 5/16 X X X X X X X X
16 – 14 5/16 X X X X X X X X
12 – 10 5/16 X X X X X X X
PV-R,
PV-F,
PV-FF,
PV-RX,
PV-FX
Vinyl insulated rings
and forks (includes
expanded insulation)
26 – 22 3/16 X X X
22 – 18 5/16 X X X X X X X X X
16 – 14 5/16 X X X XX X X X X X
12 – 10 5/16 X X X X X X X
PV-R,
PV-RX
Vinyl insulated large
ring terminals
8 3/8 X‑
6 7/16 X‑
4 1/2 X‑
2 1/2 X X‑
PV-SLF Vinyl insulated short
locking forks
22 – 18 5/16 X X X X X
16 – 14 5/16 X X X X X X
12 – 10 5/16 X X X
Mechanical
CT-720


Produktspezifikationen

Marke: Panduit
Kategorie: Nicht kategorisiert
Modell: PV14-10R-M
Produktfarbe: Blau
Material: Kupfer
Menge pro Packung: 100 StΓΌck(e)
Nachhaltigkeitszertifikate: RoHS
Beschichtung Steckerkontakte: Kupfer
Steckerverbindergeschlecht: MΓ€nnlich/Weiblich
AbisolierlΓ€nge: 9.7 mm
Maximale Kabelquerschnitt: 2.5 mmΒ²
Minimum Kabelquerschnitt: 1.5 mmΒ²
KabelstΓΌck (AWG): 16 - 14