Ozito PSA-001 Bedienungsanleitung

Ozito Pumpe PSA-001

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung fĂŒr Ozito PSA-001 (6 Seiten) in der Kategorie Pumpe. Dieser Bedienungsanleitung war fĂŒr 11 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/6
PRESSURE
SWITCH
10 BAR
INSTRUCTION MANUAL
SPECIFICATIONS
Input: 220-240V~50Hz
Pump Max: 1.1kW, 10 Amps
Max. Pressure: 10 bar (1 Mpa)
Inlet & Outlet: 25.4mm (1“BSP) Male
Water Temp.: 1ÂșC to 35ÂșC
Cable Male Plug: 1.5m
Cable Female Socket: 0.5m
IP Rating: IP65
Weight: 1.7kg
PSA-001
STANDARD EQUIPMENT
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from
the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: O-rings, bearing,
seals gaskets.
WARNING
The following actions will result in the warranty being void.
‱ If the tool has been operated on a supply voltage other
than that specified on the tool.
‱ If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
‱ Failure to perform maintenance as set out within the
instruction manual.
‱ If the tool is disassembled or tampered with in any way.
‱ Professional, industrial or high frequency use.
WARRANTY
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
ozito.com.au
0518
Pressure Switch
TeïŹ‚on Tape
ONLINE MANUAL
Scan this QR Code with your
mobile device to take you to
the online manual.
1. Discharge outlet
2. LED’s
3. Restart button
4. Brass union (knuckle)
5. Inlet
6. Female socket
7. Male plug
PRESSURE SWITCH
KNOW YOUR PRODUCT
1. ASSEMBLY
SETUP & PREPARATION
WARNING!: ENSURE THE PRESSURE SWITCH
IS DISCONNECTED FROM THE POWER SUPPLY
BEFORE PERFORMING ANY OF THE FOLLOWING
OPERATIONS.
ACCESSORIES
8. Teontape
Connecting the Pressure Switch
1. Screw the pressure switch
brass union to the transfer
pump outlet of a suitable
pump.Tightenrmlywitha
spanner (not included).
Note:Teontapeisrequiredonthreadstoensureawatertight
seal and prevent any leakage.
Connecting to the Pumps Suction Inlet
1. Insert 1” male threaded
adaptor (not included).
Tightenrmlywitha
spanner (not included).
2. Securely attach the
input hose or pipe (not
included) to the other end
of the adaptor. Ensure
you have the correct
diameter hose or pipe that
is compatible with your
water drawing source and
pump.
1
8
4
5
6
7
3
2
Primingthepumpisrequiredtopurgeairfromthehose.Don’t
operate the pump without it being primed.
1. Ensure the pump is
switched off at the mains
power.
2. Remove the priming plug
from the top of the pump
housing by turning anti
clockwise.
3. Fill the pump completely
with water. Ensure the
pump and inlet pipe or
hose are full. Replace the priming plug.
4. To fully prime the pump refer to “Starting the pump”.
2. PRIMING THE PUMP
OPERATION
WARNING!: THIS PRODUCT IS INTENDED
FOR PUMPING WATER IN A HOME DOMESTIC
APPLICATION. DO NOT USE IT FOR CORROSIVE,
ABRASIVE, EXPLOSIVE OR DANGEROUS LIQUIDS.
CAUTION. THE PUMP SHOULD BE FILLED WITH
WATER AFTER EACH NEW CONNECTION OR IF WATER
LOSS OR AIR INTAKE HAS OCCURRED. EXTENDED
OPERATION WITHOUT A WATER REFILL WILL DAMAGE
THE PUMP!
Connecting to the Discharge Outlet
1. Insert a 1” female threaded
adaptor (not included).
tightenrmlywitha
spanner.
2. Securely attach the
output hose or pipe (not
included) to the other end
of the adaptor. Ensure
you have the correct
diameter hose or pipe
that is compatible with
your water discharge
application.
Note: The discharge hose or pipe you are using must have a
minimum diameter of 19mm (3/4’’).
Note: Ensure the discharge hose or pipe is not restricted in any
way and nothing is obstructing the hose or pipe when the pump
is in operation.
WARNING!: RISK OF INJURY! IF THE
COMPONENTS ARE NOT COMPRESSION-PROOF
OR IF THEY ARE IMPROPERLY INSTALLED, THE
PRESSURE LINE COULD BURST DURING OPERATION.
Connecting to the Female Socket
1. Connect the pump power
cord plug to the pressure
switch female socket


Produktspezifikationen

Marke: Ozito
Kategorie: Pumpe
Modell: PSA-001

Brauchst du Hilfe?

Wenn Sie Hilfe mit Ozito PSA-001 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Pumpe Ozito

Bedienungsanleitung Pumpe

Neueste Bedienungsanleitung fĂŒr -Kategorien-