Orion ORH-028D Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Orion ORH-028D (6 Seiten) in der Kategorie Luftbefeuchter. Dieser Bedienungsanleitung war für 8 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/6
U
US
SE
ER
R
S
S
G
GU
UI
ID
DE
E
U
UL
LT
TR
RA
AS
SO
ON
NI
IC
C
D
DI
IG
GI
IT
TA
AL
L
H
HU
UM
MI
ID
DI
IF
FI
IE
ER
R
M
MO
OD
DE
EL
L
O
OR
RI
IO
ON
N
O
OR
RН
Н-
-0
02
28
8D
D
(
(E
En
ng
gl
li
is
sh
h)
)
www.orion.ua / support@orion.ua
2
CONTENTS
PRECAUTIONS.................................................................………………………………… 2
FUNCTIONS AND FEATURES………………………….…………………………………… 3
DIRECTIONS FOR USE………………………………………………………………………. 3
FILTER………………………………………………………………………………………….. 3
MAINTENANCE………………………………………………………………………………… 4
SPECIFICATIONS………… …………………….………………………………………………….. 4
TROUBLE SHOOTING………………..…………………..………………………………….. 4
DEAR CUSTOMERS!
MANY THANKS FOR BUYING ORION ULTRASONIC HUMIDIFIER!
We really believe you will get the greatest pleasure from using this device for the years!
Please, read the user’s guide in detail before first using of this ultrasonic humidifier
PRECAUTIONS
This product should be used only in accordance with the specifications outlined in this manual. Usage other
than what has been specified here may result in serious injury.
1. Place the body horizontally at a suitable place, and the angle of slope less than 5°.
2. Don’t use soap when you clean the water tank and bath, please use washing-powder.
3. Never touch the oscillating transduction piece with a sharp hard tool. Clean it with wet cloth only.
4. During cleaning, avoid water entryinto the body, lest the internal electric components should become damp
and faulty,
5. Don’t remove the body components at will.
6. Don’t add hot water of above 40 to the water tank and water bath to avoid discoloratin or distortion.
7. When the room temperature is below0, please empty the water tank and water bath, lest the icing of
water should damage the components.
8. Don’t place metals, chemicals and detergents into the water bath, otherwise there might be poor
atomzation.
9. When there is much water in the water bath, do not move it about, otherwise water might overflow and flow
into the body to cause troubles.
10. Don’t pur the unit at a place with strong light or direct hot air radiation.
11. When the unit is not to use for a long time, please cut off the power and unplug the plug.
12. Never pour out the water remaining in the water bath without turning off power, otherwise the transducer
will be burned out immediately
13. Don’t turn on the plug woth a wethand, otherwise there might be the risk of electric shock.
14. When the body is inclinde, please handle this with the power cut off.
15. Don’t touch the transduction piece upon starting, otherwise you will have the feel of pain.
16. Don’t disassemble the unit without cutting off the power to avoid an electric shock.
17. Don’t replace the power cord without authorization.
Failure to comply with the warnings listed above may result in electric shock or serious injury.
www.orion.ua / support@orion.ua
3
FUNCTIONS AND FEATURES
LED Ultrasonic Humidifer (Computer controlled)
Cool mist
Room Temperature and Humidity showing
Adjustable humidify and mist volume
Timer setting
Two modes (AUTO and MANUAL)
Auto cut out when waterless with alarm
Anion Function
Using the nanometer technology effectively remove heavy metal.(filter option)
Ultrasonic high frequency oscillation atomize the water into mist quickly
Whisper-quiet cool mist operation
Modern design. Safe and easy to use
DIRECTIONS FOR USE
1. Place the body horizontally at a suitable place.
2. Take out the water tank, screw off the tank cover where writing “Add Water Here” and top up clean tap
water.
3. Screw down the cover and put the water tank on the right way.
4. Connect the unit to a 220V/50HZ power supply, turn on the power switch and the humidifying indicator
will be illuminated.
5. There is staged adjustment of mist output, which is set to the humidifying your room. Adjusted the mist
through to press “-”or”+” button
6. Press the “ANION” key when you want to make anion air, the indicator light will be on at the same time.
7. When there is no water in the water tank, the built-in safety device will cut out the power automatically.
To continue the operation, please turn off the power and refill the water tank.
8. Manul mode: There are auto and manual working model, please press the “SETUP” button if you want
to change the model. The acquiescent model is auto when you press power button. It’s follow “humidity
setting”→ →”time setting” ”quit setting””auto model””humidity setting” when you press “SETUP
button each time. In addition,“humidity setting”time setting””quit setting” are belong to manual
working model.
9. Humidity setting: Adjusted the mist through to press “-”or”+” button, the set point is 50%-90%. Humidifier
will start automatically when humidity is below the seting humidity, stoped when above the seting digital,
other fuction will not be changed.
10. Time setting: Set the time through to press”-” or”+”button, the set point is 0.5-8 hours. Increase or
reduce 0.5 hours when press the button each time. Humidifier will be turned off automatically when time
is out. Please press the power button again when you want to turn on the machine.
11. Quit setting: Quit setting and keep the humidity setting and time setting.
12. There is build-in water less device. Machine will be stop, the LCD will twinkle and showing “−−” with
alarm bell of ” di di………” when water less.
FILTER
This filter clears and softs heavy water, improves water quality.
Features:
Making water molecules smaller, easier to penetrate the cell membrane, increase cell activity and
human immunity.
Eliminate water odor and chlorine, eradicate harmful substances and carcinogens.
Weak water alkaline to help the body acid-base balance and nutritional balance.
Incrase water Microelements which human body need, including calcium, magnesium, sodium,
potassium,etc, and all kinds of mineral substance.
High conductivity and low OPR promote digestion, prevention of aging and longevity benefit.
Filter Characteristics remain unchanged under any condition no matter effected by sun, temperature,
pressure,etc.
Note:
Filter should be Cleaned each month and can be used all along.
Recommended period of use of washable filter is 2 years with frequent use.


Produktspezifikationen

Marke: Orion
Kategorie: Luftbefeuchter
Modell: ORH-028D

Brauchst du Hilfe?

Wenn Sie Hilfe mit Orion ORH-028D benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Luftbefeuchter Orion

Bedienungsanleitung Luftbefeuchter

Neueste Bedienungsanleitung für -Kategorien-