Oregon Scientific BARM699A Bedienungsanleitung
Oregon Scientific
Wetterstation
BARM699A
Lesen Sie kostenlos die š deutsche Bedienungsanleitung fĆ¼r Oregon Scientific BARM699A (3 Seiten) in der Kategorie Wetterstation. Dieser Bedienungsanleitung war fĆ¼r 21 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/3
Touch-Control AM/FM Atomic Weather
Clock with Dual Alarm
Model: BARM699A
USER MANUAL
INTRODUCTION
Thank you for selecting the Oregon Scientiļ¬c
TM Touch-
Control AM/FM Atomic Weather Clock with Dual
Alarm (BARM699A). The main unit can support up
to 3 sensors. To purchase additional sensors, please
contact your local retailer.
NOTE Please keep this manual handy as you use
your new product. It contains practical step-by-step
instructions, as well as technical speciļ¬cations and
warnings you should know about.
OVERVIEW
FRONT VIEW
1. : Activate snooze; set the sleep SLEEP / SNOOZE
timer
2. : Turn radio ON / OFFRADIO ON / OFF
3. STATION: Toggle between 16 preset radio channels;
save a channel
4. : Increase / decrease volume VOLUME /
5. : Change setting / display CLOCK
6. : Toggle between AM and FM AM / FM
7. : Increase / decrease TUNING / SET /
setting; activate / deactivate clock reception signal;
change radio frequency
BACK VIEW
1. MEMORY: View current, maximum and minimum
temperature
2. : Switch remote sensor displayCHANNEL
3. Adapter socket
4. : View alarm status; set alarm ALARM
5. : Select temperature unit Ā°C / Ā°F Ā°C / Ā°F
6. : Reset unit to default settingsRESET
LCD
1. Ice warning
1
5
6
7
2
3
4
14
5
6
2
3
18
7
9
10
13
14
15
16
17
18
20
19
11
12
2
3
4
5
6
2. Weather forecast
3. Preset radio station number
4. AM / FM station; radio frequency in MHz or KHz and
volume level
5. Radio-controlled clock reception icon
6. 12-hour clock
7. Indoor temperature display icon
8. Channel number and sensor reception status
9. Sensor low battery warning
10. Outdoor temperature reading
11. Maximum / minimum outdoor temperature reading
12. Main unit low battery warning
13. Indoor temperature reading
14. Maximum / minimum indoor temperature reading
15. Sleep function is activated
16. Alarm is displayed
17. Beep alarm is set
18. Radio alarm is set
19. US time zone, weekday or seconds
20. Time, alarm and date
REMOTE SENSOR
1. LED status indicator:
Blinks red during data
transmission
2. Ventilation duct
1. Wall mount
2. Battery compartment
3. Battery door
4. Table stand
5. switchCHANNEL
GETTING STARTED
POWER
Plug adapter into main unit.
NOTE This product may malfunction when radio
interference appears on the AC power line. The unit will
revert to normal operation when interference stops.
NOTE Install the remote sensor battery and plug in the
main unit. Press RESET after each battery change. Do
not use rechargeable batteries. It is recommended that
you use alkaline batteries with this product for longer
performance.
shows when battery is low.
UNIT LOCATION
Main Indoor temperature area
Remote Outdoor temperature area
REMOTE SENSOR
The sensor collects temperature readings approx. every
40 seconds and sends them to the main unit. The main
unit can collect data from up to 3 sensors.
To set up the sensor:
1. Slide open the battery door.
2. Insert the battery, matching the polarity (+ / -).
3. Select a channel. Make sure you use a different
channel for each sensor.
4. Close the battery compartment.
5. Secure the sensor in the desired location using the
wall mount or table stand.
1 2 3
CHANNEL
1
2
3
4
5
1
2
For best results:
ā¢ Place the sensor out of direct sunlight and
moisture.
ā¢ Do not place the sensor more than 30 meters (100
feet) from the main (indoor) unit.
ā¢ Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls,
and furniture.
ā¢ Place the sensor in a location with a clear view to
the sky, away from metallic or electronic objects.
ā¢ Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may
affect battery performance and signal transmission.
The transmission range may vary depending on many
factors. You may need to experiment with various
locations to get the best results.
Standard Alkaline batteries contain signiļ¬cant
amounts of water. Because of this they will freeze
in low temperatures of approximately -12Ā°C (10Ā°F).
Disposable Lithium batteries have a much lower
threshold for temperature with an estimated freezing
range of below -30Ā°C (-22Ā°F).
Wireless ranges can be impacted by a variety of factors
such as extremely cold temperatures. Extreme cold
may temporarily reduce the effective range between the
sensor and the base station. If the unitās performance
fails due to low temperature, the unit will resume proper
functioning as the temperature rises to within the
normal temperature range (i.e. no permanent damage
will occur to the unit due to low temperatures).
SENSOR DATA TRANSMISSION
The reception icon shown in the outdoor temperature
area shows the status.
ICON DESCRIPTION
Main unit is searching for
the sensor(s)
A channel has been found
and signal is being
received
and ā- -ā The sensor cannot be found.
(Outdoor temperature Search for the sensor or
area) check the battery
To search for a sensor
:
Simultaneously, press and hold MEM CHANNEL and
for 2 seconds.
NOTE The sensor LED ļ¬ashes when data is being
sent to the main unit. If the sensor signal is still not
found, check the battery, obstructions, and remote unit
location.
LIGHT TOUCH KEY
The touch keys used in this product have a key lock
function that prevents accidental changes to user
settings. When the clock keys have not been used in
the last minute, the key lock function is automatically
activated. Press any key once to disable the key lock
function and then operate the clock as usual.
CLOCK RECEPTION
This product is designed to synchronize its date and
time automatically once it is within range of the WWVB-
60 signal from the atomic clock in Boulder, Colorado.
The sensor collects the radio signals whenever it is
within 3219 km (2000 miles) of a signal.
NOTE Initial reception takes 2-10 minutes for ļ¬rst set
up or when RESET is pressed. Once complete, the
reception icon will stop blinking. If the signal is weak, it
can take up to 24 hours to get a valid signal.
RECEPTION SIGNAL
STRONG WEAK NO SIGNAL
To enable and force a signal search:
Press and hold for 2 seconds.TUNING / SET
To disable the signal reception
:
Press and hold for 2 seconds. TUNING / SET
ļ¬ashes when it is searching for the atomic clock
signal and disappears when it is disabled.
CLOCK
To manually set the clock make sure the clock signal
reception is disabled.
To manually set the clock:
1. Press and hold CLOCK for 2 seconds.
2. Press TUNING / SET / to change the
settings.
3. Press CLOCK to conļ¬rm.
4. The setting sequence is: US time zone, 12 / 24
hour format, hour, minute, year, day / month format,
month, day, and display language.
NOTE The US time zone options are Paciļ¬c (PA),
Mountain (MO), Central (CE) and Eastern (EA).
NOTE The language options are (E) English, (F)
French, (D) German, (I) Italian, and (S) Spanish.
To switch the clock display:
Press to toggle between:CLOCK
ā¢ Clock with seconds
ā¢ Clock with weekday
ā¢ Calendar
ALARM
To set the alarm:
1. Press ALARM to view the alarm. will show on
the display.
2. Press and hold ALARM for 2 seconds.
3. Press TUNING / SET / to change the hour,
minute, beep or radio alarm. If you select the radio
alarm, press and AM / FM STATION to select the
band and station respectively.
4. Press ALARM to conļ¬rm.
To activate or deactivate the alarm:
Press when in the alarm display. or ALARM
appears when the alarm is set.
To silence the alarm:
ā¢ Press to silence it for 8 minutes.SNOOZE
OR
ā¢ Press any key except to turn the alarm off SNOOZE
and activate it again after 24 hours.
NOTE or ļ¬ashes when snooze is activated.
WEATHER FORECAST
This product forecasts the weather for the next 12 to 24
hours within a 19-31 mile (30-50 km) radius, with 70 to
75 percent accuracy.
SUNNY PARTLY CLOUDY CLOUDY RAINY
TEMPERATURE
To change the temperature measurement unit:
Press on the bottom of the unit.Ā°C / Ā°F
To view outdoor sensor(s) temperature readings
:
Press . CHANNEL
ā¢ shows which remote sensorās data you are
viewing.
ā¢ is permanently displayed in the indoor
temperature area.
To auto-scan between sensors:
Press and hold CHANNEL for 2 seconds. Each sensorās
data is displayed for 3 seconds.
To end auto-scan:
Press or CHANNEL MEMORY.
To toggle between current, minimum and maximum
records for the selected sensor:
Press MEMORY repeatedly.
To clear the records:
Select the channel to clear the memory, then press and
hold MEMORY for 2 seconds.
NOTE The indoor memory record will be cleared
simultaneously.
ICE WARNING
If the channel 1 sensor falls between 3Ā°C to -2Ā°C (37Ā°F
to 28Ā°F), will ļ¬ash to warn you that the temperature
is approaching freezing.
NOTE The alarm will automatically stop if the
temperature goes outside the ice-warning range.
RADIO
You can save up to 16 radio stations (8 for AM and 8
for FM).
To turn the radio ON / OFF:
Press . RADIO
To save a station:
1. Press RADIO to turn the radio ON.
2. Press AM / FM to select radio frequency.
3. Press TUNNING / SET / to manually ļ¬ne
tune the frequency or press and hold TUNNING /
SET / to activate auto-search.
4. Press and hold STATION to save the station.
SLEEP TIMER
To turn the sleep timer ON:
1. Press SLEEP once to activate the last setting
used.
2. Press SLEEP to set radio sleep timer duration (120,
90, 60, 30, 15 or 0 minutes). Select ā0ā to disable
the sleep timer.
3. Press to change the volume.VOLUME /
NOTE āSLEEPā ļ¬ashes when the sleep timer is
activated.
BACKLIGHT
Press any key to activate the backlight for 1 minute.
RESET
Press to return the main unit to the default RESET
settings. Remove and then re-insert the batteries to
reset the sensor.
PRECAUTIONS
This product is engineered to give you years of
satisfactory service if you handle it carefully. Here are
a few precautions:
ā¢ Do not use a damp cloth to clean the surface of
the light touch key, If it is necessary to use a damp
cloth to clean the unit, turn the power off before
cleaning.
ā¢ Placement of this product on wood surfaces with
certain types of ļ¬nishes, such as clear varnish, may
result in damage to the ļ¬nish. Consult the furniture
manufacturerās care instructions for direction as
to the types of wood surface. Oregon Scientiļ¬c
shall not be responsible for any damage to wood
surfaces from contact with this product.
ā¢ Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
ā¢ Do not clean the unit with abrasive or corrosive
materials.
ā¢ Do not subject the unit to excessive force, shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and distorted parts.
ā¢ Do not tamper with the unitās internal components.
Doing so will invalidate the warranty on the unit and
may cause unnecessary damage. The unit contains
no user-serviceable parts.
ā¢ Only use fresh batteries as speciļ¬ed in the userās
instructions. Do not mix new and old batteries.
ā¢ Do not use rechargeable batteries.
ā¢ Remove batteries when storing the product for a
long time.
ā¢ Do not dispose this product as unsorted municipal
waste. Collection of such waste separately for
special treatment is necessary.
ā¢ Due to printing limitations, the displays shown in
this manual may differ from the actual display.
ā¢ The contents of this manual may not be reproduced
without the permission of the manufacturer.
NOTE The technical speciļ¬cations for this product and
the contents of the user manual are subject to change
without notice.
SPECIFICATIONS
TYPE DESCRIPTION
Main unit
Dimensions 163 x 65.4 x 96 mm
(L x W x D) (6.4 x 2.6 x 3.8 inches)
Weight 300g (10.6 ounces)
Temperature unit ā Ā°C / Ā°F
Indoor range -5Ā°C to 50Ā°C (23Ā°F to 122Ā°F)
Outdoor range -30Ā°C to 60Ā°C (-22Ā°F to 140Ā°F)
Resolution 0.17Ā°C (0.2Ā°F)
Radio clock
Synchronization Auto or disabled
Clock display HH:MM
Hour format 12hr AM/PM or 24hr
Calendar DD/MM or MM/DD
Weekday in 5 (E, G, F, I, S)
languages
Alarm 2-minute beep or radio alarm with
8-minute snooze
PLL Radio FM / AM; MHz / KHz; 16 preset
channels
Sleep 120, 90, 60, 30 and 0 mins
Remote unit (THN132N)
Dimensions 92 x 22 x 50 mm
(L x W x D) (3.6 x 0.9 x 2.0 inches)
Weight 46 g (1.62 lbs) without battery
RF frequency 433MHz
Range Up to 30 meters (100 feet) with no
obstructions
Transmission Approx. every 40 seconds
Channel no. 1, 2 or 3
Power
Main unit 6V adapter
Remote unit 1 x UM-3 (AA) 1.5V battery
NOTE We recommend that you use alkaline batteries in
the sensor for longer usage and lithium batteries for use
in temperatures below freezing.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientiļ¬c.com) to
learn more about Oregon Scientiļ¬c products such as
digital cameras; MP3 players; childrenās electronic
learning products and games; projection clocks; health
and ļ¬tness gear; weather stations; and digital and
conference phones.
The website also includes contact information for our
Customer Care department in case you need to reach
us, as well as frequently asked questions and customer
downloads. We hope you will ļ¬nd all the information you
need on our website, however if youāre in the US and
would like to contact the Oregon Scientiļ¬c Customer
Care department directly, please visit:
www2.oregonscientiļ¬c.com/service/default.asp OR call
1-800-853-8883. For international inquiries, please visit:
www2.oregonscientiļ¬c.com/about/international.asp
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
WARNING Changes or modiļ¬cations not expressly
approved by the party responsible for compliance could
void the userās authority to operate the equipment.
NOTE This equipment has been tested and found
to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
ā¢ Reorient or relocate the receiving antenna.
ā¢ Increase the separation between the equipment
and receiver.
ā¢ Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
ā¢ Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact
for support or sales. Please call our customer service
number (listed on our website at www.oregonscientiļ¬c.
com), or on the warranty card for this product) for all
inquiries instead.
We
Name: Oregon Scientiļ¬c, Inc.
Address: 19861 SW 95th Ave., Tualatin,
Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: BARM699A
Product Name: Wireless Thermometer with
Self-Setting Clock and FM
Radio
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St., Hung
Hom, Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: 1)
This device may not cause harmful interference. 2) This
device must accept any interference received, including
interference that may cause undesired operation.
Ā© 2006 Oregon Scientiļ¬c. All rights reserved.
086L004256-013
Produktspezifikationen
Marke: | Oregon Scientific |
Kategorie: | Wetterstation |
Modell: | BARM699A |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Oregon Scientific BARM699A benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Wetterstation Oregon Scientific
2 September 2024
27 August 2024
27 August 2024
27 August 2024
27 August 2024
21 August 2024
21 August 2024
19 August 2024
19 August 2024
Bedienungsanleitung Wetterstation
- Wetterstation Clatronic
- Wetterstation Hama
- Wetterstation Lexibook
- Wetterstation Nedis
- Wetterstation Tchibo
- Wetterstation Clas Ohlson
- Wetterstation Cotech
- Wetterstation Profile
- Wetterstation Adler
- Wetterstation Camry
- Wetterstation Velleman
- Wetterstation ADE
- Wetterstation Alecto
- Wetterstation Auriol
- Wetterstation Beurer
- Wetterstation Bresser
- Wetterstation Cresta
- Wetterstation Day
- Wetterstation Denver
- Wetterstation Dexford
- Wetterstation Durabase
- Wetterstation ECG
- Wetterstation EMOS
- Wetterstation Eurochron
- Wetterstation Gira
- Wetterstation HomeMatic
- Wetterstation Irox
- Wetterstation Jacob Jensen
- Wetterstation Kemot
- Wetterstation Kƶnig
- Wetterstation MarQuant
- Wetterstation Mebus
- Wetterstation Medisana
- Wetterstation Mesko
- Wetterstation National Geographic
- Wetterstation Prologue
- Wetterstation Renkforce
- Wetterstation Sempre
- Wetterstation Techno Line
- Wetterstation Technoline
- Wetterstation Telefunken
- Wetterstation TFA
- Wetterstation ThinkGizmos
- Wetterstation Thomson
- Wetterstation Trevi
- Wetterstation Ventus
- Wetterstation Weinberger
- Wetterstation Ytora
- Wetterstation Trotec
- Wetterstation Blaupunkt
- Wetterstation Braun
- Wetterstation Rocktrail
- Wetterstation Daewoo
- Wetterstation Pyle
- Wetterstation Muse
- Wetterstation Avidsen
- Wetterstation Elro
- Wetterstation GoGEN
- Wetterstation Hyundai
- Wetterstation Orion
- Wetterstation Livoo
- Wetterstation Perel
- Wetterstation Soehnle
- Wetterstation Balance
- Wetterstation Fysic
- Wetterstation Sencor
- Wetterstation Krontaler
- Wetterstation Honeywell
- Wetterstation MINOX
- Wetterstation Lowrance
- Wetterstation Globaltronics
- Wetterstation ELV
- Wetterstation Guardo
- Wetterstation Unitec
- Wetterstation Netatmo
- Wetterstation Ascot
- Wetterstation Theben
- Wetterstation Brandson
- Wetterstation Tanita
- Wetterstation JUNG
- Wetterstation Johnson
- Wetterstation OBH Nordica
- Wetterstation Optex
- Wetterstation Davis
- Wetterstation Levenhuk
- Wetterstation Vitek
- Wetterstation Prestigio
- Wetterstation EQ-3
- Wetterstation EVE
- Wetterstation Extech
- Wetterstation Daikin
- Wetterstation Fluke
- Wetterstation La Crosse Technology
- Wetterstation Homematic IP
- Wetterstation EQ3
- Wetterstation Elgato
- Wetterstation Digi-tech
- Wetterstation DMV Electronics
- Wetterstation Ea2 LABS
- Wetterstation EMOS SELECT
- Wetterstation Garni
- Wetterstation Hesdo
- Wetterstation Inovalley
- Wetterstation IT
- Wetterstation Kaindle
- Wetterstation La Crosse
- Wetterstation Meade
- Wetterstation Nasa
- Wetterstation Nor-tec
- Wetterstation Otio
- Wetterstation Paget Trading
- Wetterstation PCE Instruments
- Wetterstation Saxon
- Wetterstation Taylor
- Wetterstation Thierry Mugler
- Wetterstation UPM
- Wetterstation Uzoli
- Wetterstation Waldbeck
- Wetterstation Xeecom ApS
- Wetterstation TFA Dostmann
- Wetterstation Vimar
- Wetterstation PeakTech
- Wetterstation AcuRite
- Wetterstation Chauvin Arnoux
- Wetterstation Brigmton
- Wetterstation Chacon
- Wetterstation Baldr
- Wetterstation Garin
- Wetterstation ChiliTec
- Wetterstation Global Water
- Wetterstation Greisinger
- Wetterstation Marathon
- Wetterstation Majestic
- Wetterstation Gewiss
- Wetterstation ClimeMET
- Wetterstation Buienradar
- Wetterstation Balance Meteo
- Wetterstation Rebel
- Wetterstation JDC
- Wetterstation Greenure
- Wetterstation Browin
- Wetterstation Setti+
- Wetterstation Bearware
Neueste Bedienungsanleitung fĆ¼r -Kategorien-
15 Oktober 2024
8 Oktober 2024
5 Oktober 2024
3 Oktober 2024
2 Oktober 2024
30 September 2024
29 September 2024
29 September 2024
24 September 2024
24 September 2024