Newco FC-AP Bedienungsanleitung


Lesen Sie kostenlos die đź“– deutsche Bedienungsanleitung fĂĽr Newco FC-AP (12 Seiten) in der Kategorie Kaffeemaschine. Dieser Bedienungsanleitung war fĂĽr 5 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/12
Oct. 18, 17 NEI 1.800.325.7867 www.newcocoffee.com | P a g e 1
FC SERIES BREWERS
Installation/Operation Manual
FC-S3 FC-5 FC-3 FC-TD FC-AP FC-LD FC-S
FC-TS
Oct. 18, 17 NEI 1.800.325.7867 www.newcocoffee.com | P a g e 2
Table of Contents
Plumber’s Install Instructions ___________________________________________ Page: 3
Brewer Set Up Procedures ____________________________________________ Pages: 3 & 4
Coffee Preparation Procedures _________________________________________ Page: 4
Telescoping Brewer Operation Procedures ________________________________
Pages: 4 thru 6
Temperature & Volume Adjustment Settings _______________________________
Pages: 7 & 8
Wiring Schematics ___________________________________________________ Page: 9
Addendum to Operation Manual_________________________________________
Page: 10
Product Warranty ___________________________________________________ Page: 11
Oct. 18, 17 NEI 1.800.325.7867 www.newcocoffee.com | P a g e 3
PLUMBER’S INSTALLATION INSTRUCTIONS:
1. Flush water line before installing brewer. Brewer should be connected to cold water line for best performance – operation.
2. Water pressure should be at 20 lbs. For less than a 25 ft. run, use 1/4" copper tubing and connect to a 1/2" or larger water
line. For longer runs, use 3/8” copper tubing and connect to a 1/2" or larger water line. An adaptor fitting should be used to
connect to the brewer.
3. If installed with a saddle valve, the valve should have a minimum 1/8” porthole up to 25 ft. In excess of 25 ft., use a 5/16”
porthole.
4. Connect incoming water line to the flow control attached to the elbow extending from the back of the brewer. Manufacturer
recommends using copper tubing to make connection.
BREWER SET UP PROCEDURES:
WARNING: READ AND FOLLOW INSTALLATION INSTRUCTIONS BEFORE PLUGGING OR WIRING
IN THE BREWER TO AN ELECTRICAL CIRCUIT. WARRANTY WILL BE VOIDED IF BREWER IS
CONNECTED TO ANY VOLTAGE OTHER THAN SPECIFIED ON THE SERIAL TAG.
1. Make sure that the on-off switch, located on the back of the brewer, is in the “off” position. This switch controls only the tank
element and will prevent the element from being damaged during tank’s initial water fill up.
2. Plug, or wire brewer, to appropriate voltage circuit as indicated on the serial tag. Turn on the lower warmer switch [warmer
models] or power switch [thermal models] to the “on” position to supply power to the brewer. Unplug the brewer from the
power source.
3. While depressing the black start button, plug the brewer back in to its power source. This will activate the water fill to the
required operating volume level. (Once the water starts to fill the hot water tank… the start button can be released. Note: If the
brewer is powered up prematurely, before depressing the start button, the hot water tank will not fill to the optimum volume level.
If the water probe does not sense water within one (1) minute, an error light [Auto Arm] will flash. To reset this function, turn “off”
the power switch and turn it back “on” defaulting back to the initial set up function. Repeat the water fill procedure again.)
4. Turn the “on-off” switch, located in the rear of the brewer, to the “on” position. This activates the tank’s element initializing the
heating process for brewing operations. [Allow 15 to 20 minutes for the hot water tank to reach optimum operating temperature.]
5. Volume Setting: Place an empty glass decanter, or thermal dispenser, in position underneath the brew basket. With the
vessel in place, depress the black start button to begin a brew cycle. Observe the volume of water being delivered in to the
vessel. If the water volume comes up short…increase [+] the time on the timer [clockwise]. If the water volume comes up
long…decrease [-] the time on the timer [counter clockwise]. {FYI… Turning off the power switch [red lighted rocker switch] will
“stop” the brewing operations.}
6. Temperature Setting: After the water has reached brewing temperature, the thermostat will click off and the green “ready”
light will illuminate. Brew one cycle checking optimum brewing temperature by using an accurate thermometer like a digital or
mercury thermometer. Place the thermometer underneath the brew basket opening, at the beginning of the brew cycle and when
the vessel is halfway full. The recommended brewing temperature is 195 degrees Fahrenheit. [Note: The brewing cycle can be
canceled at any time be depressing the black


Produktspezifikationen

Marke: Newco
Kategorie: Kaffeemaschine
Modell: FC-AP

Brauchst du Hilfe?

Wenn Sie Hilfe mit Newco FC-AP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Kaffeemaschine Newco

Bedienungsanleitung Kaffeemaschine

Neueste Bedienungsanleitung fĂĽr -Kategorien-