DISASSEMBLY/REPAIR INSTRUCTIONS
R2000WF Repair 2/2020
Cap Removal Tool
GENERAL DISASSEMBLY
1. from the ACME thread of REMOVE THE SPRINKLER
the quick change adapter.
2. SEPARATE THE CAP FROM THE BODY by squeezing
the release points (the words SQUEEZE) while
turning counter-clockwise. For easy removal, use
the #10689 Cap Removal Tool. Position the tool (as
shown on the right) to apply pressure to the words
SQUEEZE.
3. Use the #12260 2TN Nozzle Removal Tool to
REMOVE THE 2TN NOZZLE from the body. Place
the tool at the top of the R2000WF body and press
down. The nozzle should easily pop out.
WARNING: Always use the #12260 tool to remove a 2TN nozzle from a
R2000WF Rotator. Never use a stick, rod, or any other object to push on
the outlet of the 2TN nozzle to remove. This can easily damage the plate
bearing surface and cause rotation failure.
4. REMOVE THE PLATE by placing your fingers in the
open space in the cap (between the washer and
plate). Pull towards you until the plate pops up
away from the cap.
5. REMOVE THE MOTOR from the cap bytting the
Motor Removal Tool #12215 onto the top of the cap.
Press on the outer ring of the motor removal (1)
tool so it fits tightly against the cap. Press on (2)
the inner circle of the tool so the motor disengages
from the cap. Gently push the motor from the top to
completely remove it from the cap assembly.
Nozzle
oval
Motor Removal Tool
40 and 65 PSI (2.8 to 4.5 BAR)
Proper assembly is essential to
product satisfaction.
Plate
Body
2TN Nozzle
Quick Change
Adapter
Motor
Cap
Diffuser
Washer
Cap Assembly
1 1
2
NELSON IRRIGATION CORPORATION
848 Airport Rd., Walla Walla, WA 99362 U.S.A.
Tel: 509.525.7660 Fax: 509.525.7907 info@nelsonirrigation.com
NELSON IRRIGATION CORPORATION OF AUSTRALIA PTY. LTD.
35 Sudbury Street, Darra QLD 4074
Tel: +61 7 3715 8555 Fax: +61 7 3715 8666 info@nelsonirrigation.com.au
NELSON IRRIGAÇÃO BRASIL LTDA.
Rua Benedita Mano Schincariol, 110 Santa Cruz, Mogi Mirim, SP 13800-443
Tel: +55 (19) 98816-4992 www.nelsonirrigation.com.br
WARRANTY AND DISCLAIMER: Nelson R2000WF Rotators are warranted for one year from the date of original sale to be free of defective material and workmanship when used within the working specifications for which the
products were designed and under normal use and service. The manufacturer assumes no responsibility for installation, removal or unauthorized repair of defective parts and the manufacturer will not be liable for any crop or
other consequential damages resulting from any defects or breach of warranty. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR PARTICULAR PURPOSES AND OF ALL OTHER OBLIGATIONS OR LIABILITIES OF MANUFACTURER. No agent, employee or representative of the manufacturer has authority to waive, alter or add to the provisions
of this warranty nor to make any representations or warranty not contained herein. This product may be covered by one or more of the following U.S. Patent Numbers 4796811, RE33823, DES312865, 5058806, 5372307, 5875815
and other U.S. Patents pending or corresponding issued or pending foreign patents.
GENERAL ASSEMBLY
1. SELECT THE NEW PARTS — nozzle, plate and/or motor that will be used in the assembly.
Always be sure the nozzle size is recommended for the plate and the motor. See graph
on right.
2. While holding the cap in one hand,
INSTALL THE MOTOR by first setting the
diffuser in place (small teeth against the
ridges in the cap) and topping it off with
the washer. Direct the motor into the hole
of the cap assembly. Align the hole of the
Motor Assembly Tool (the disc that ships
with part #12215) on the shaft of the
motor and snap motor into place.
3. Next, ASSEMBLE THE PLATE TO THE CAP
ASSEMBLY. Place the cap assembly in
one hand and the WF Plate in the other.
Orient the two components so the ats
of the motor shaft and plate are parallel
as shown below. Gently push the plate
onto the shaft. The plate is correctly
installed once you have felt two distinct
“clicks” as you push the plate on. Do not
continue pushing after you have felt the
plate snap into place. Damage to the plate
and/or other parts may occur, resulting in
unsatisfactory sprinkler operation.
2. CONNECT THE CAP/PLATE ASSEMBLY TO
THE BODY by holding the body in one
hand and fastening the cap/assembly
with a clockwise turn of the other hand.
3. PLACE A 2TN NOZZLE INTO THE BASE OF
THE WF BODY with the small end of the
nozzle pointed towards the cap.
4. PLACE A QUICK CHANGE ADAPTER INTO THE
BASE OF THE BASE OF THE BODY and turn
clock-wise. Confirm that there is a o-ring
in place. Assembly is now complete.
SPRINKLER LESS ADAPTER
COMPLETE
R2000WF CAP
& BODY ASSY
WF MOTOR
COLOR
COMPLETE
R2000LP CAP
& BODY ASSY
LP
MOTOR
COLOR
10 10 Purple Green 9928-1010 9929-1010
12 11 Green 9928-1211 Ivory 9929-1211
12 Green 9928-1212 Ivory 9929-1212
14
9928-1413 Ivory 9929-1413 Purple
14 Purple9928-1414 Ivory 9929-1414
16
15 Purple9928-1615 Ivory 9929-1615
16 Purple9928-1616 Ivory 9929-1616
18 18 Purple9928-1818 Ivory 9929-1818
20 20 Purple9928-2020 Ivory 9929-2020
NOZZLE
PLATE
or Assembly Tool
Motor
Plate
Flat sides of the shaft
must be parallel
to the flats at top
center of the plate.
Flats on plate
Flat side
of shaft


Produktspezifikationen

Marke: Nelson
Kategorie: Bewässerungskontrolle
Modell: R2000WF

Brauchst du Hilfe?

Wenn Sie Hilfe mit Nelson R2000WF benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Bewässerungskontrolle Nelson

Bedienungsanleitung Bewässerungskontrolle

Neueste Bedienungsanleitung für -Kategorien-