Morco GB24 Series III Bedienungsanleitung

Morco Ketel & boiler GB24 Series III

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Morco GB24 Series III (44 Seiten) in der Kategorie Ketel & boiler. Dieser Bedienungsanleitung war für 3 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/44
Jan 2021
UIN 220216 A04
User & Installation Instructions
GB24 & GB30
Series III
Propane
8 8
rest ar t
Morco House, Riverview Road, Beverley, East rkshire, HU17 0LDYo
Morco Produc Ltdts
Tel: 01482 325456 Fax: 01482 212869
Website: www.morcoproduc .co.ukts
To Domestic Hot Water:
GB24-Propane Minimum 4.9 kW (16,600 Btu/h)
GB30-Propane Minimum 6.1 kW (20,700 Btu/h)
GB24-Propane Maximum 24.2 kW (82,570 Btu/h)
GB30-Propane Maximum 30.3 kW (103,384 Btu/h)
To Central Heating:
GB24-Propane Minimum 4.9kW (16,600 Btu/h)
GB30-Propane Minimum 6.1 kW (20.700 Btu/h)
GB24-Propane Maximum 17.2 kW (58,728 Btu/h)
GB30-Propane Maximum 20.4 kW (69,607 Btu/h)
BOILER OUTPUT
min ma x min max
mod e
of f
e
re st a rt
2
MODEL
SYMBOL UNITS 24 30
Condensing Boiler n/a n/a yes yes
Low Temperature Boiler n/a n/a no no
B1 Boiler n/a n/a no no
Cogeneration Space Heater n/a n/a no no
Equipped with a Supplementary Heater n/a n/a no no
Combination Heater n/a n/a yes yes
Nominal Heat Output for Space Heating
Full Load P kW 17.2 20.44
Part Load P kW 5.6 5.71
Auxiliary Electricity Consumption
Full Load el kW 0.023 0.022max
Part Load el kW 0.010 0.010min
Standby P kW 0.003 0.003SB
Seasonal Space Heating Energy Efîš¿ciency
Full Load Æž4% 91.7 92.0
Part Load Æž1% 99.2 100.4
Standby Loss P kW 0.050 0.050stby
Ignition P kW 0 0ign
Emissions Gross NO mg/kWh 32 38x
Annual Energy Consumption Q GJ 53 61HE
Sound Power Level, Indoors L dB 42 39WA
Domestic Hot Water
Domestic Hot Water Qelec kWh 0.121 0.119
Water heating energy efîš¿ciency (Eco)
Tapping Proîš¿le XL
hHW % 74 75
Daily fuel consumption 24hr (GCV) Actual
measured
Qfuel kWh 8.090 7.954
Annual electricity consumption AEC kWh 26 26
Annual fuel consumption AFC GJ 6 6
ERP DATA
All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. You can check your installer by calling Gas Safe
Register direct on 0800 4085500.
3
MORCO COMBINATION BOILER
Morco Products Ltd
ERP DATA
SYMBOL UNITS MODEL
24 30
Condensing boiler Yes
Seasonal Space heating efîš¿ciency class A
Rated heat output kW 17 20
Seasonal space heating energy efîš¿ciency Æžs% 94* 95
Annual energy consumption Q GJ 53 61HE
Sound power level, indoors L dB 42 39WA
Water heating energy efîš¿ciency class A
Seasonal Space Heating Energy Efîš¿ciency of the Boiler *%
Temperature control (from îš¿che of temperature control) %
Class I Class II Class III Class IV Class V Class VI Class VII Class VIII
1% 2% 1.5% 2% 3% 4% 3.5% 5%
PRODUCT FICHE
 
The energy efîš¿ciency of the package of products provided for in this document may not correspond to its actual energy efîš¿ciency once installed in a
building, as the efciency is inuenced by further factors such as heat loss in the products in relation to the building size and its characteristics
Collector Size
(in m2)
Tank Volume
(in m3)
Collector
Efîš¿ciency
(in %)
Tank rating
A* = 0.95
A = 0.91
B = 0.86
C = 0.83
D-G = 0.81
Solar Contribution (from îš¿che of solar device)
Seasonal Space Heating Energy Efîš¿ciency of Package TOTAL: A+B+C=
Seasonal Space Heating Energy Efîš¿ciency Class of Package
= (‘ + ‘ ) x 0.9 x (III ’x IV ’ x / 100 x = %
%
G F E D C B A A+ A++ A+++
< 30% ≥ 30% ≥ 34% ≥ 36% ≥ 75% ≥ 82% ≥ 90% ≥ 98% ≥ 125% ≥ 150%
A
B
C

Produktspezifikationen

Marke: Morco
Kategorie: Ketel & boiler
Modell: GB24 Series III

Brauchst du Hilfe?

Wenn Sie Hilfe mit Morco GB24 Series III benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Ketel & boiler Morco

Bedienungsanleitung Ketel & boiler

Neueste Bedienungsanleitung für -Kategorien-