Mistral M2020C Bedienungsanleitung

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Mistral M2020C (8 Seiten) in der Kategorie niet gecategoriseerd. Dieser Bedienungsanleitung war für 2 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
3-In-1
Bathroom Heater
Model: M2020C
Instruction Manual
2
Important Safeguards
• This bathroom heater is not intended for use
by persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
• Children should be supervised to ensure that
they do not play with the appliance.(i.e. wall
switch)
• Ensure that the switch is in the off position
when changing the heat lamp (globe) or
light globe.
• Ensure that the wattage of the centre
replacement light globe is the same as the
globe
supplied with the unit.
• E27 275W heat globes can be used in this unit.
• Ensure the grille is free of objects, dust build
up, etc. Make sure that the airow through
the grille is not inhibited.
• Means for disconnection must be
incorporated in the xed wiring, in
accordance with the wiring rules.
• Precautions must be taken to avoid the back-
ow of gases into the room from the open
ue of gas or other fuel burning appliances.
• When cutting the ceiling material, care must
be taken to ensure you do not damage
electrical wiring and other hidden utilities.
• This bathroom heater is to be installed so
that switches or other controls can not be
touched by a person in the bath or shower.
• The lamps are extremely hot when in use. Do
not touch to the lamps with any part of your
body when in use. Allow all lamps cool down
sufciently before touching or replacement.
• The appliance shall, under no circumstances,
be covered with insulating material or similar
material.
Cleaning
• Ensure the Mistral bathroom heater is
switched off and cool down sufciently
before cleaning.
• Remove globes when they are at room
temperature. Wipe with a damp cloth, never
immerse.
• Unclip lamp surround and wash in warm
soapy water. Always use a soft cloth, never
abrasives.
• Clean away any excess uff from the inside of
the body, motor blade brackets.
• The exhaust fan requires regular cleaning
to ensure optimum performance. With the
power off, regularly wipe the fan clear of dust
and dirt.
• Clean the exhaust ducting kit, ensuring there
are no obstructions at the exit.
Warning
If the power cord is damaged, the power cord
must be replaced by either the service agent
or similarly qualied persons in order to avoid a
hazard.
This product has not been designed for any uses
other than those specied in this booklet.
Save These Instructions
3
Fitting Instructions
Thank you for purchasing Mistral bathroom
heater. This product combines heat globes
an exhaust fan and light, to provide gentle
radiant heat, clean air and a bright light from
one compact, stylish unit. This model allows for
exhausting of steam and odours right out of your
home. All functions are separately controlled
from a supplied switch plate for convenient
ngertip control.
You can be assured trouble free operation by
getting your Mistral Bathroom heater carefully
installed by a qualied electrician, according
to the instructions. Please read all instructions
before commencing installation.
Mistral Bathroom heater can be mounted in
any room that requires instant, direct, and
radiant heat to ward off winter chills. The light
has separate switching, making it suitable for
bathrooms, ensuites, toilets, dressing & change
rooms.
Suitability
The Mistral Bathroom Heater has been designed
especially for cavity type ceilings. Flat roof
installation is NOT recommended.
This product must not be mounted in areas
subject to direct splashing, and must be
mounted in the horizontal position only.
Unsuitable for ‘cathedral’ or ‘raked’ ceilings.
This model comes with 4 Infrared Heat Globes
which emit harmless radiant heat. It is best
positioned directly above the area requiring
warmth. Before you start, make sure your ceiling
has at least 280mm clearance from the roof (see
to the ‘Mounting’ diagram).
Where to Locate
Radiant globe heaters are not designed to heat
entire rooms. They provide instant, concentrated
heat to persons standing directly below the heat
lamps. Therefore, Mistral Bathroom heater should
be located over the area where drying off takes
place, not directly over a shower or bath.
This Heater is not designed to be left on for
extended periods of time, as this could cause
overheating and premature failure. Mistral
Bathroom Heater, should not be covered or
installed in situations which restrict the natural
ventilation of the units for cooling purposes.
Ceiling insulation should be kept well clear
of the units (at least 100mm). For optimum
performance, models with exhaust fans should
be installed in areas with good ventilation,
to enable fresh air to ow into the room. Any
restrictions on return air entering the room will
impair effectiveness and may contribute to
premature failure.
Radiant Heat
The Mistral Bathroom Heater requires no warm
up period because of its efcient, radiant heat
globes. Heat is directed at you for an instant
warmth you can feel, rather than gradually
warming the entire room. Because of this, Mistral
Bathroom Heater only needs to be turned ON
when you are in the room.
General Illumination
A 6 watt light is designed to provide general
illumination only. Additional lighting may be
required for duties.

Produktspezifikationen

Marke: Mistral
Kategorie: niet gecategoriseerd
Modell: M2020C

Brauchst du Hilfe?

Wenn Sie Hilfe mit Mistral M2020C benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung niet gecategoriseerd Mistral

Bedienungsanleitung niet gecategoriseerd

Neueste Bedienungsanleitung fĂźr -Kategorien-