User's Manual
Encompass LCD
UPS Series
Para Systems, Inc.
1455 Lemay Dr.
Carrollton, TX 75007
Phone: 1-972-446-7363
Fax: 1-972-446-9011
Internet: minutemanups.com
UPS Sizing: sizemyups.com
PN - 34000530 R1
1
1. Introduction 2
2. Controls and Indicators 6
3. Installation 9
4. Operation 12
5. Configurable Parameters & Settings 17
6. Obtaining Service 18
7. Troubleshooting 19
8. Replacing the Battery 20
9. Specifications 24
10. Limited Product Warranty 26
A1. Declaration of Conformity 27
Table Of Contents
32
Thank you for purchasing this power protection product. It has been designed
and manufactured to provide many years of trouble free service. Please read
this manual before installing your Encompass On-Line Series UPS, models
EC1000LCD, EC1500LCD, EC2000LCD, EC3000LCD as it provides impor-
tant information that should be followed during the installation and the mainte-
nance of the UPS system allowing you to correctly set up your system for the
maximum safety and performance. Included is information on customer sup-
port and factory service, if it is required. If you experience a problem with the
UPS system please refer to the Troubleshooting guide in this manual to correct
the problem or collect enough information so that the Technical Support De-
partment can assist you.
SAVE THESE INSTRUCTIONS - This manual contains important instructions
that should be followed during the installation and the maintenance of the UPS
system and the batteries.
CAUTION! The maximum ambient operating temperature for this UPS series
is 40°C (“0 ~ 40°C” for Ambient Operation).
ïźThe external vents and openings on the UPS are provided for ventilation.
To ensure reliable operation of the UPS and to protect the UPS from over-
heating, these vents and openings must not be blocked or covered. Do not
insert any object into any of the vents or openings that may hinder the ve-
ntilation.
ïźInstall the UPS system in a well ventilated area, away from excess moistu-
re, heat, dust, flammable gas or explosives.
ïźLeave adequate space (at least 20cm) in the front and at the rear of the
UPS system for proper ventilation.
ïźDo not mount the UPS system with its front or rear panel facing down at
any angle.
ïź Before usage, you must allow the UPS system to adjust to room temper-
ature (20°C~25°C or 68°F~77°F) for at least one hour to avoid moisture
condensing inside the UPS.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS !
CONSIGNES DE SÉCURITÉ IMPORTANTES
SAUVEGARDEZ CES CONSIGNES!
Veuillez lire ce manuel avant l'installation de l'onduleur modĂšles EC1000LCD,
EC1500LCD, EC2000LCD, EC3000LCD. Il contient de l'information importante
qui doit ĂȘtre respectĂ©e au cours de l'installation et de l'entretien de l'onduleur et
des batteries. Cette information vous permettra de correctement installer le
systÚme pour atteindre son rendement maximum en toute sécurité.
Chapter 1: Introduction
WARNING: Risk of Electrical Shock. Hazardous live parts inside these
power supplies are energized from the battery even when the AC input is
disconnected.
CAUTION! To reduce the risk of electrical shock in conditions where the
load equipment grounding cannot be verified, disconnect the UPS from the
AC wall outlet before installing a computer interface cable. Reconnect the
power cord only after all signaling connections are made.
CAUTION! Connect the UPS to a two pole, three wire grounded AC wall
outlet. The receptacle must be connected to the appropriate branch protec-
tion (circuit breaker or fuse). Connection to any other type of receptacle may
result in a shock hazard and violate local electrical codes. Do not plug the
UPS into extension cords, adapter plugs or surge strips.
CAUTION! To reduce the risk of electrical shock with the installation of this
UPS equipment and the connected equipment, the user must ensure that the
combined sum of the AC leakage current does not exceed 3.5mA.
WARNING: This Uninterruptible Power Supply contains potentially hazard-
ous voltages. Do not attempt to disassemble the UPS beyond the battery
replacement procedure. This UPS contains no user serviceable parts. Re-
pairs and battery replacement must be performed by QUALIFIED SERVICE
PERSONNEL ONLY.
CAUTION! To reduce the risk of fire, connect only to a utility powered
circuit provided with 20 / 30 amperes maximum branch circuit over-current
protection in accordance with the National Electric Code, ANSI/NFPA 70.
WARNING: Qualified Service Personnel ONLY must perform the Installa-
tion and Servicing of these UPS systems. MINUTEMAN accepts no liabilities
and is not limited to: injury to the User or Service Personnel, or damages to;
the UPS, or the connected equipment caused by the incorrect installation or
servicing of the UPS system.
CAUTION! This UPS series is ONLY intended to be installed in an indoor
temperature controlled environment that is free of conductive contaminants.
This UPS series is not intended for use in a computer room as defined in the
Standard for the Protection of Electronic Computer/Data Processing Equip-
ment ANSI/NFPA 75.
NOTE: These UPSs are shipped with the batteries disconnected. The batter-
ies must be connected before putting these UPSs into service. Refer to Sec-
tion 3 "Installation" for connecting the batteries.


Produktspezifikationen

Marke: Minuteman
Kategorie: Unterbrechungsfreies Stromversorgungssystem
Modell: EC1000LCD-NC

Brauchst du Hilfe?

Wenn Sie Hilfe mit Minuteman EC1000LCD-NC benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem Minuteman

Bedienungsanleitung Unterbrechungsfreies Stromversorgungssystem

Neueste Bedienungsanleitung fĂŒr -Kategorien-