Middle Atlantic Products IBGR-552FT Bedienungsanleitung
Middle Atlantic Products
Hardwarekühlung
IBGR-552FT
Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Middle Atlantic Products IBGR-552FT (8 Seiten) in der Kategorie Hardwarekühlung. Dieser Bedienungsanleitung war für 8 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet
Seite 1/8
middleatlantic.com | middleatlantic.ca
what are built on.great systems ™
96-01149 / rev d / 12-5-16
BGR Series
19” gangable enclosures
next generation rack, designed with significant
installation and performance benefits
features:
• Provides more rackspace in a smaller overall height than similar racks
• Accepts patent-pending Lever Lock™ tool free and hardware free internal
device and cable management system accessories
• Fully welded construction provides the following weight capacities:
UL Listed load capacity: 3,000 lbs., Seismic certified capacity: 1,175 lbs.
• Pre-threaded ganging holes allow for rack joining after loading
• Rackrail depth indicators
• 1/2”, 3/4”, 1” & 1-1/2” electrical knockouts and 5/8” and 1/2” D UHF/VHF
antennae knockouts on rear top & bottom, easily removable for cable
pass-through. Top cable management plate (38 space and up) includes 1/2”,
3/4”, 1” 1-1/2” & 3” electrical knockouts and 5/8” and 1/2” D UHF/VHF
antennae knockouts
• 23” OD width, multiple depths
• Two pairs of 11-gauge, 10-32 threaded rackrail with numbered rackspace
increments
• Optional stackable 3” extender bay available for front and rear
• Optional curved and beveled front doors in solid, vented and plexiglass styles
• Attractive interior bevels
• Configurable open top with vertical cable management entry points
• Durable black textured powder coat finish
• Seismic certified (when used with BGR-Z4 or BGR-ISO-Z4 option) with
an Ip value of 1.5
• UL Listed in the US and Canada
BGR shown with curved
door and side panels
BGR shown with beveled
door and side panels
EI A/T I A C O MP L IA NT
SE I S M I C C E R TI FI E D
middleatlantic.com | middleatlantic.ca
what are built on.great systems ™
2
BGR Series
19” gangable enclosures
EIA compliant 19” gangable equipment rack shall be Middle Atlantic Products model # BGR-__-
__(see chart for available models). Overall dimensions of BGR shall be __”H x 23”W x __”D (refer
to chart). Useable height of BGR shall be __ rackspaces, useable depth shall be__” (refer to chart).
BGR shall come equipped with two pairs of fully adjustable steel rackrail with tapped 10-32 mounting
holes in universal EIA spacing, black e-coat finish and numbered rackspaces. BGR shall have .100”
thick steel along rackrail brackets, .310” thick steel at corners. BGR shall include vented locking
and latching rear door, which shall be capable of accepting up to six 4-1/2” fans. Top and bottom of
BGR shall feature vertical slotted vent pattern for ventilation. BGR shall have two 1” x 7”rear obround
knockouts with 1/2”, 1”, 1-1/4” and 1-1/2” electrical knockouts and 5/8” and 1/2” D UHF/ VHF
antennae knockouts in base and top. BGR shall have a configurable open top with vertical cable
management entry points. BGR shall accept patent-pending LeverLock™ tool free and hardware free
internal cable and device management system accessories. BGR shall have pre-threaded 5/16”-18
ganging holes. BGR shall be capable of ganging while fully loaded, using bolts only. BGR shall have
marked rackrail depth indicators. BGR shall be of fully welded construction. BGR shall be finished in
an environmentally friendly, durable black powdercoat. Grounding and bonding studs shall be 1/4-20
threaded, installed in top and base of enclosure (19 and 25 space have stud in bottom only). Fully
welded construction shall provide a static capacity of 12,000 lbs. and a UL Listed load capacity of
3,000 lbs. BGR Series enclosures shall satisfy the 1997 UBC; 2001, 2007 & 2010 CBC; 2000,
2003, 2006 & 2009 IBC; ASCE 7-02, ASCE 7-05, ASCE 7-10 and the 2003, 2006 & 2009 editions
of NFPA 5000 for use in areas of high seismicity, Seismic Use Group III, Zone 4 or Seismic Design
Category (SDC) “D” with lateral force requirements for protecting 1,175 lbs. of essential equipment in
locations with the highest level of seismicity and top floor or rooftop installations with an Importance
factor (Ip) of 1.5 when used with BGR-Z4 or BGR-ISO-Z4 (isolated) seismic floor anchor bracket. BGR
shall be OSHPD approved for fixed equipment anchorage in California healthcare facilities. BGR shall
be UL Listed in the US and Canada. BGR shall be GREENGUARD Gold Certified. BGR enclosure shall
meet the RoHS EU Directive 2011/65/EU. BGR shall be manufactured by an ISO 9001 and ISO
14001 registered company. BGR enclosure shall be warrantied to be free from defects in material or
workmanship under normal use and conditions for the lifetime of the rack.
Customizable specification clips available at middleatlantic.com
specifications:
options:
• Lever Lock™ tool free and hardware free internal
device and cable management system accessories
shall be model # LL-XXYY (XX = type, YY = size,
refer to middleatlantic.com for additional details)
• Curved front doors shall be model # VFD-XXA (vented,
64% open area), PFD-XXA (plexi), (XX= # of rackspaces)
• Beveled front doors shall be model # BFD-XX (solid),
BVFD-XX (vented, 64% open area), BPFD-XX (plexi),
(XX= # of rackspaces)
• Front or Rear Extender, adds 3” of usable depth,
model # BGR-__-EXT3 (41,45)
• Cable entry rear door, shall be model # BGR-RDC__
(19, 25, 38, 41, 45)
• Inner platform base shall be BS-BGR
• Caster kit shall add 1” to overall height, include four
casters with a 1,100 lb. weight capacity, and shall be
model # CBS-BGR
• Rear rail kit shall be model # BGR-RRXX (XX=# of
rackspaces)
• Removable keylocked side panels shall be model
# BSPN-XX-YY (XX=rackspaces, YY=depth)
• Seismic Zone 4, Seismic Use Group III and Seismic
Design Category “D” compliancy kit shall be model
# BGR-Z4
• Seismic Zone 4, Seismic Use Group III and Seismic
Design Category “D” compliancy and isolation kit shall
be model # BGR-ISO-Z4
• Seismic Zone 4, Seismic Use Group III and Seismic
Design Category “D” riser bases shall be
SRB-(1,2,3)-BGR-(32, 38)24
• Isolation kit shall be model # BGR-ISO
• Front decorative trim shall be BGR-TRIM__(45,41,38,
25, 19) and shall include the following colors: Green
(pre-installed), Red, Black, Blue & White
Part # Rackspaces
“A”
Overall Height
“B”
Racking Height
“C”
Depth
“D”
Useable Depth
BGR-1927 19 37.375 [949] 33.375 [848] 27 [686] 24.4 [620]
BGR-2527 25 47.875 [1216] 43.875 [1114] 27 [686] 24.4 [620]
BGR-3827 38 70.625 [1794] 66.625 [1692] 27 [686] 24.4 [620]
BGR-4127 41 75.875 [1927] 71.875 [1826] 27 [686] 24.4 [620]
BGR-4527 82.875 [2105] 78.875 [2003]45 27 [686] 24.4 [620]
BGR-2532 25 47.875 [1216] 43.875 [1114] 29.4 [747]32 [812]
BGR-3832 38 70.625 [1794] 66.625 [1692] 29.4 [747]32 [812]
BGR-4132 41 75.875 [1927] 71.875 [1826] 32 [812] 29.4 [747]
BGR-4532 82.875 [2105] 78.875 [2003] 29.4 [747]45 32 [812]
BGR-4138 41 75.875 [1927] 71.875 [1826] 38 [965] 35.4 [899]
BGR-4538 82.875 [2105] 78.875 [2003] 38 [965] 35.4 [899]45
middleatlantic.com | middleatlantic.ca
what are built on.great systems ™
3
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
BGR Series
basic dimensions
Note: BSPN-XX-XX adds 0.656 [17] per side to
width (removable side panels)
A
A
19.90 ] m [505 (botto opening)
B
21.00 [ ]533
21.13
[537]
23.0 ][584
C
C
23.0 ][584
C
2.00
[508]
1.31 [33]
1.00 [25]
1.30
[33]
4x ø .69 [17] (floor mounting holes)
1.86 [47]
1.32
BGR-XX27= 21.91 ][556
BGR-XX32= 26.91 ][683
BGR-XX38= 32.91 ][836
bottom gopenin
BGR-XX27= 6 ]23.1 [588
BGR-XX32= 28.16 [715]
BGR-XX38= 6 ]34.1 [867
floor m sounting hole
front view side view
Le Lockver ™
compatible,
horizontal
Le Lockver ™
compatible,
vertical
rear view
vent ins rear door
also accept 4-1/2" fans
remo .3vable ø1 3 [34]
x ] 7.5 [190 LKO
1/4-20 x 1"
grounding stud
1/4-20X1" grounding stud
bottom view
3x ø 1/2" [13] 'D' LKO
for F UHF/VH antenna
2X 1/2" 3][1
EKO e trad size
2X X 1" [25] 1-1/4"
[32]
EKO e trad size
5/8" [16] LKO rfo
UHF/VHF antenna
1.91 [48]
5X
3.75 [95] 2X 1.10 [27.9]
5.22
[133]
4 x ø .688 [17.48] OLK
4 x ø 1/2" [13] 'D' LKO r fo UHF/VHF antenna
4X 3" [76] X X O 1-1/2" [38] 1" [25] EK trade size
2 x ø 5/8" [16] LKO r F afo UHF/VH antenn
2x 4-1/2" fan sknockout
key e O rhol LK fo
optional wood top
fixed rhole fo
optional wood top
top viewtop view
25sp & runde38sp & over
A
D
max rear rail
set back
(u h)seable dept
19.15 [486] r mfloo ounting
23.0 ][584
13.0 ][330
4.61 [117]
7.56
4X ø 1/2" [13] 'D' LKO
for UHF/VHF antenna
21.0 [533] x 21.13 ][537
rect LKO
2X ø 5/8" [16] LKO
for UHF/VHF antenna
2.03 [52]
2.00
[51]
5X 3/4" [19] X 1/2" [13]
EKO trade size
2.22
[56]
Produktspezifikationen
Marke: | Middle Atlantic Products |
Kategorie: | Hardwarekühlung |
Modell: | IBGR-552FT |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Middle Atlantic Products IBGR-552FT benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Hardwarekühlung Middle Atlantic Products
2 September 2024
2 September 2024
2 September 2024
2 September 2024
2 September 2024
2 September 2024
2 September 2024
2 September 2024
2 September 2024
2 September 2024
Bedienungsanleitung Hardwarekühlung
- Hardwarekühlung Asus
- Hardwarekühlung Corsair
- Hardwarekühlung Gigabyte
- Hardwarekühlung Zalman
- Hardwarekühlung Enermax
- Hardwarekühlung Cooler Master
- Hardwarekühlung NZXT
- Hardwarekühlung SilverStone
- Hardwarekühlung Thermaltake
- Hardwarekühlung EVOLVEO
- Hardwarekühlung Be Quiet!
- Hardwarekühlung Alphacool
- Hardwarekühlung AZZA
- Hardwarekühlung Noctua
- Hardwarekühlung APC
- Hardwarekühlung Akasa
- Hardwarekühlung Emerson
- Hardwarekühlung In Win
- Hardwarekühlung Antec
- Hardwarekühlung Intel
- Hardwarekühlung StarTech.com
- Hardwarekühlung Alpenföhn
- Hardwarekühlung Arctic Cooling
- Hardwarekühlung AeroCool
- Hardwarekühlung Crestron
- Hardwarekühlung Mars Gaming
- Hardwarekühlung Savio
- Hardwarekühlung ENDORFY
- Hardwarekühlung DeepCool
- Hardwarekühlung EK Water Blocks
- Hardwarekühlung SilentiumPC
- Hardwarekühlung Raijintek
- Hardwarekühlung Dynatron
- Hardwarekühlung Chieftec
- Hardwarekühlung Thermalright
- Hardwarekühlung ALSEYE
- Hardwarekühlung CoolerMaster
- Hardwarekühlung Iceberg Thermal
- Hardwarekühlung Bitspower
- Hardwarekühlung Cryorig
Neueste Bedienungsanleitung für -Kategorien-
26 September 2024
26 September 2024
24 September 2024
21 September 2024
21 September 2024
21 September 2024
12 September 2024
12 September 2024
12 September 2024
12 September 2024