2
G SAFETY WARNINGS
Safety warnings must be read and understood before instrument is used.
The following safety information must be observed to insure maximum
personal safety during the operation of this meter:
Do not use in wet environments.
Measurements beyond the maximum selected range must not be attempted.
Extreme care must be taken when measuring above 50 V, especially on live
bus-bars.
To measure voltage, the instrument must not be switched to a current or
resistance range, or to the diode check or buzzer position.
Circuits must be de-energised and isolated before carrying out resistance
tests.
The rotary selector switch must only be turned after removing test
connections.
All external voltages must be disconnected from the instrument before
removing the battery.
Test leads and prods must be in good order, clean, and with no broken or
cracked insulation.
UK Safety Authorities recommend the use of fused test leads when measuring
voltage on high energy systems.
Replacement fuses must be of the correct type and rating.
The instrument must not be used if any part of it is damaged.
Check for correct instrument operation by testing a known voltage before
and after use. Do not use if misleading results are obtained.
Warnings and precautions must be read and understood before an instrument
is used. They must be observed during the operation of this instrument.
CAT IV - Measurement category IV: Equipment connected between the origin
of the low-voltage mains supply and the distribution panel.
CAT III - Measurement category III: Equipment connected between the
distribution panel and the electrical outlets.
CAT II - Measurement category II: Equipment connected between the
electrical outlet and the user’s equipment.
Note
This instrument must only be used by suitably trained and competent persons
3
Safety warnings 2 ............................................................................................
Symbols used on instrument 3 ........................................................................
Introduction 4 .................................................................................................
Operation 5 .....................................................................................................
Specifications 10 .............................................................................................
Manual de l’utilisateur 16 ...............................................................................
Bedienungsanleitung 30 .................................................................................
Manual del usuario 44 ....................................................................................
Gebruikershandleiging 56 ...............................................................................
Symbols used on the instrument are:
F Caution: risk of electric shock
G Caution: refer to accompanying notes
t Equipment protected throughout by Double Insulation (Class II)
c Equipment complies with current EU directives.
END OF LIFE DISPOSAL
The crossed out wheeled bin placed on the Megger products is a
reminder not to dispose of the product at the end of its product life
with general waste.
Megger is registered in the UK as a Producer of Electrical and Electronic
Equipment. The Registration number is WEE/HE0146QT.
BATTERIES
Should the display fail to illuminate then change the battery. For the purpose of
end of life disposal and battery replacement, removing the two screws on the
base of the unit accesses the battery.
The crossed out wheeled bin placed on the battery is a reminder not to dispose
of it with general waste at the end of its life.
This product contains 1 x PP3 / 6F22 alkaline battery.
Do not use rechargeable batteries.
The battery fitted in this instrument is classified as a Portable Battery and
should be disposed of in the UK in accordance with Local Authority
requirements.
For disposal of batteries in other parts of the EU contact your local distributor.
Megger is registered in the UK as a Producer of Batteries. The registration
number is BPRN00142.
Contents
Produktspezifikationen
Marke: | Megger |
Kategorie: | Multimeter |
Modell: | AVO410 |
Brauchst du Hilfe?
Wenn Sie Hilfe mit Megger AVO410 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Multimeter Megger
4 September 2024
20 August 2024
1 September 2023
1 September 2023
1 September 2023
Bedienungsanleitung Multimeter
- Multimeter Basetech
- Multimeter Gembird
- Multimeter Brennenstuhl
- Multimeter Clas Ohlson
- Multimeter Profile
- Multimeter REV
- Multimeter Voltcraft
- Multimeter Bosch
- Multimeter Laserliner
- Multimeter Velleman
- Multimeter Powerfix
- Multimeter Alecto
- Multimeter EMOS
- Multimeter TFA
- Multimeter FERM
- Multimeter Topcraft
- Multimeter Schneider
- Multimeter Tacklife
- Multimeter Abus
- Multimeter Elro
- Multimeter Stanley
- Multimeter Perel
- Multimeter Wago
- Multimeter Workzone
- Multimeter Somogyi
- Multimeter Amprobe
- Multimeter Metrix
- Multimeter Maxwell
- Multimeter Silverline
- Multimeter Yato
- Multimeter Brandson
- Multimeter Keithley
- Multimeter Hager
- Multimeter Kyoritsu
- Multimeter GW Instek
- Multimeter Monacor
- Multimeter Brüder Mannesmann
- Multimeter Milwaukee
- Multimeter JUNG
- Multimeter Testo
- Multimeter Elma
- Multimeter IDEAL
- Multimeter Digitus
- Multimeter Kingcraft
- Multimeter Testboy
- Multimeter Projecta
- Multimeter Greenlee
- Multimeter Multimetrix
- Multimeter Extech
- Multimeter BENNING
- Multimeter Metrel
- Multimeter Högert
- Multimeter APPA
- Multimeter Fluke
- Multimeter FLIR
- Multimeter Aldi
- Multimeter Gossen Metrawatt
- Multimeter Hubinont
- Multimeter Joy-it
- Multimeter Kewtech
- Multimeter Mastech
- Multimeter Micronta
- Multimeter PCE Instruments
- Multimeter Plieger
- Multimeter Sanwa
- Multimeter Skandia
- Multimeter Sonel
- Multimeter Steren
- Multimeter Uni-T
- Multimeter Wiha
- Multimeter Vimar
- Multimeter Owon
- Multimeter PeakTech
- Multimeter Amiko
- Multimeter Rigol
- Multimeter HT Instruments
- Multimeter Beha-Amprobe
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter Etekcity
- Multimeter Rohde & Schwarz
- Multimeter Strex
- Multimeter MBS
- Multimeter Kurth Electronic
- Multimeter Weidmüller
- Multimeter CEM
- Multimeter Klein Tools
- Multimeter Dasqua
- Multimeter Horex
- Multimeter Enovalab
- Multimeter Qian
- Multimeter Digi-tool
- Multimeter MGL Avionics
- Multimeter Cosinus
- Multimeter Weltron
- Multimeter EEVBlog
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Bearware
- Multimeter Noyafa
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
13 Oktober 2024
9 Oktober 2024
5 Oktober 2024
5 Oktober 2024
3 Oktober 2024