Installaī†±on Manual
ļ¬ Typeļ¼š
ļ¼š
ļ¼š
ļ¼šļ¼šDRA DIN rail power supply Series DRA-40, DRA-
ļ¼ˆ
ļ¼ˆ
ļ¼ˆ
ļ¼ˆļ¼ˆ ļ¼š
ļ¼š
ļ¼š
ļ¼šļ¼š 60ļ¼‰
ļ¼‰
ļ¼‰
ļ¼‰ļ¼‰
DRA- - INPUT: -240VAC 0.8A 50/60Hz OUTPUT: V 3.34A 40 12 100 12
DRA- - INPUT: -240VAC 0.8A 50/60Hz OUTPUT: V 1.7A 40 24 100 24
DRA- - INPUT: -240VAC 1.3A 50/60Hz OUTPUT: V 5A 60 12 100 12
DRA- - INPUT: -240V 1.3A 50/60Hz OUTPUT: V 2.5A 60 24 100 AC 24
ļ¬ Introducī†±on
DRA is a DIN rail power supply series featuring adjustable output current. Users are able to set its output current to
a range of 10% - 100% of rated current via 1-10Vdc, PWM signal or resistance. Like other Mean Well s DIN series, ā€™
they can be mounted on a TS35 Standard DIN rail.
ļ¬ Installaī†±on
ļ¼ˆ ļ¼‰1 Always allow good venī†¼laī†¼on clearances, 5mm leī…· and right, 40mm above and 20mm below, around the unit
in use to prevent it from overheaī†¼ng. Also a 10-15 cm clearance must be kept when the adjacent device is a
heat source.
ļ¼ˆ ļ¼‰2 The appropriate mounī†¼ng orientaī†¼on for the unit is verī†¼cal, the input terminals the bottom and output on at
the top. Mounī†¼ng orientaī†¼ons other than that, such as upside down, horizontal, or table-top mounī†¼ng, is not
allowed.
ļ¼ˆ ļ¼‰3 Use copper wire only, and recommended wires are shown as below.
AWG
18
16
14
12
Rated Current of
Equipment (Amp)
7
10
15
20
Cross-secī†¼on of
Lead(mm2 )
0.8
1.3
2.1
3.3
Note Current each wire carries should be de-rated to 80% of the current suggested ļ¼š
above when using 4-6 wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connecī†¼on and the screw terminals are
securely ī…™xed to prevent poor contact. If the power supply possesses mulī†¼-output terminals, please make
sure each contact is connected to wires to prevent too much current stress on a single contact.
ļ¼ˆ ļ¼‰4 Use wires that can withstand temperatures of at least 80Ā°C, such as UL1007.
ļ¼ˆ ļ¼‰5 Recommended wire strapping length m (0.197 . is 5m ā€)
ļ¼ˆ ļ¼‰6 Recommended screwdriver is 3 , sloī‡†ed type.mm
ļ¼ˆ ļ¼‰7 The recommended torque seī‡ˆng for terminals(TB1) is 5 kgfā€cm (4.4 Lbā€in),
terminals(TB2) is 5 5 .8 kgfā€cm ( Lbā€in).
ļ¼ˆ ļ¼‰8 Each unit requires 0.15mA when dimming funcī†¼on is used. Please make sure your controller is capable of
driving the units.
Installaī†±on Manual
3
1
2
ļ¼ˆ ļ¼‰9 Suggested fuse and maximum number of the DRA that can be connected to a circuit breaker at 230V are shown
as below.
Model
Fuse
Circuit breaker
C16
D 16
DRA- 40
T2.5A/L250V
11
21
DRA- 60
T2.5A/L250V
8
16
ļ¼ˆ ļ¼‰10 Mounī‡—ng Instrucī‡—on ļ¼š
Mount as shown in ī…“gure only, with input terminals down, or else suī…¾cient cooling will not be possible.
Admissible DIN railļ¼šTS35/7.5 or TS35/15
For rail fastening ļ¼š
ļ¼ˆ ļ¼‰a Tilt the unit slightly rearwards.
ļ¼ˆ ļ¼‰b Fit the unit over top hat rail.
ļ¼ˆ ļ¼‰c Slide it downward unī‡—l it hits the stop.
ļ¼ˆ ļ¼‰d Press against the bottom for locking.
ļ¼ˆ ļ¼‰e Shake the unit slightly to check the locking acī‡—on.
ļ¼ˆ ļ¼‰11 For other informaī‡—on about the products, please refer to www.meanwell.com for details.
ļ¬ Warning / Cauī†±on !!
ļ¼ˆ ļ¼‰1Risk of electrical shock and energy hazard. All failure should be examined by a qualiī…“ed technician. Please do
not remove the case of the power supply by yourself!
ļ¼ˆ ļ¼‰2Risk of electric arcs and electric shock (danger to life). Connecī‡—ng both t primary and the secondary sides he
together is not allowed.
ļ¼ˆ ļ¼‰3Risk of burn hazard. Do not touch the unit in operaī‡—on and shortly aī†’er disconnecī‡—on!
ļ¼ˆ ļ¼‰4 Risk of ī…“re and short circuit. The openings should be protected from foreign objects or dripping liquids.
ļ¼ˆ ļ¼‰5 Only install the unit in a polluī‡—on degree 2 environment (Note.1).
ļ¼ˆ ļ¼‰6 Please do not install the unit in places with high moisture or near the water.
ļ¼ˆ ļ¼‰7The maximum operaī‡—ng temperature is 45 for the DRA- - , for the DRA- -24, DRC-60A and Ā°C 60 12 50Ā°C 60
DRC-60B, for the DRA- -12/24, DRC-40A and DRC-40B, please do not install the unit in places with high 55Ā°C 40
ambient temperature or near ī…“re source.
ļ¼ˆ ļ¼‰8 The FG ( ) must be connected to (Protecī‡—ve Earth). PE
ļ¼ˆ ļ¼‰9 Output current and output waī‡”age must not exceed the rated value on its speciī…“caī‡—on.
"Click"
Installaī†µon Manual
ļ¼ˆ ļ¼‰10 Disconnect system from supply voltage:
Before commencing any installaī†¹on, maintenance or modiī…•caī†¹on work: Disconnect your system from
supply voltage. Make sure that inadvertent connecī†¹on in circuit will be impossible!
Note.1: Polluī†¹on Degree 2 applies where there is only non-conducī†¹ve polluī†¹on that might temporarily become
conducī†¹ve due to occasional condensaī†¹on. Generally refer to dry, well-venī†¹lated locaī†¹ons, such as
control cabinets.
Manufacturerļ¼š
ļ¼š
ļ¼š
ļ¼šļ¼š
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Oī…–ceļ¼š
ļ¼š
ļ¼š
ļ¼šļ¼š
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: + - -758-6000 31 20
Web: www.meanwell.eu


Produktspezifikationen

Marke: Mean Well
Kategorie: Nicht kategorisiert
Modell: DRA-40-12

Brauchst du Hilfe?

Wenn Sie Hilfe mit Mean Well DRA-40-12 benƶtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Mean Well

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung fĆ¼r -Kategorien-