MBS ASK 31.3 Bedienungsanleitung

MBS Multimeter ASK 31.3

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für MBS ASK 31.3 (18 Seiten) in der Kategorie Multimeter. Dieser Bedienungsanleitung war für 2 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/18
Operating instructions /
Installation instructions
Please keep!
Low-voltage current transformer
- Plug-in current transformers -
ASK, SASK series
MBS AG
Eisbachstrasse 51
74429 Sulzbach-Laufen
Tel. +49 7976 9851-0
Fax. +49 7976 9851- 90
info@mbs-ag.com www.mbs-ag.com •
Before installation, commissioning or operation
of the device, read these instructions carefully
and thoroughly.
1. Safety instructions
CAUTION
The following points must be noted:
  The applicable laws, standards and provisions.
  The state of the technological art at the time of installation.
  The rules surrounding technology.
  The operating instructions.
ï‚· The fact that operating instructions can only include general
instructions and that these instructions must be observed.
ï‚· Before commissioning, check the device carefully for any damage
it may have sustained during transport. In the event of mechanical
damage, the device must not be put into operation.
 The devices described are designed for installation by qualied
specialist electricians and must only be installed in electrical plant
rooms or in closed housings. Any other use or failure to comply with
these usage instructions will render the warranty / guarantee null
and void.
  Devices must only be installed in dry, indoor spaces.
  Do not install on easily ammable materials.
ï‚· Operation with a rated current higher than that stated on the type
plate can result in overheating of the current transformer and burns.
2. Functional description
Current transformers in the ASK and SASK series are inductive
single-wire current transformers that operate on the transformer
principle. They are used to adapt the primary measuring parameter to
the input rated parameters of the connected measuring equipment.
As a result of the measuring principle used, these current transformers
are only suitable for use on alternating current networks.
Current transformers of the ASK and SASK series are
maintenance-free.
3. Warning information
WARNING
Dangerous electrical voltage can cause electric shock and burns.
Ensure that the information on the type plate and in the "Technical data"
under Point 5 matches the operating parameters of the system.
Before starting any installation work, disconnect the system from the
power supply!
WARNING
If there is an unladen (open) secondary circuit in the current
transformer, high voltages will be induced at its secondary
terminals. The voltage values that occur there represent a danger
to persons and to the functional safety of the current transformer.
"Open mode", i.e. operation of the current transformer
without secondary circuitry, must be avoided at all costs.


Produktspezifikationen

Marke: MBS
Kategorie: Multimeter
Modell: ASK 31.3

Brauchst du Hilfe?

Wenn Sie Hilfe mit MBS ASK 31.3 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Multimeter MBS

Bedienungsanleitung Multimeter

Neueste Bedienungsanleitung für -Kategorien-