Master MH-80TBOA-OFR Bedienungsanleitung

Master Heizung MH-80TBOA-OFR

Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für Master MH-80TBOA-OFR (15 Seiten) in der Kategorie Heizung. Dieser Bedienungsanleitung war für 14 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/15
CONSUMER: READ AND SAVE THESE IMPORTANT INSTRUCTIONS
GENERAL HAZARD WARNING:
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS
MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING
THE HEATER. Be sure to comply with the instructions and warnings provided with this heater.
Failure to comply can result in re or explosion that can cause property loss, bodily injury, or
loss of life. Only persons who can follow and understand these instructions should operate
or service this heater. Persons who are impaired or under the influence of alcohol or drugs
should not operate heater. If you need heater info; such as an operating manual, labels,
etcetera, contact Pinnacle Climate Technologies at 800-641-6996.
NOT FOR USE IN RESIDENTIAL LIVING
AREAS OR IN ENCLOSED SPACES WITHOUT
ADEQUATE VENTILATION. THIS HEATER IS
NOT FOR USE WHERE EXPOSED TO THE WEATHER, AND INDOOR
USE ONLY IN WELLVENTILATED AREAS. INDOOR USE PERMITTED
ONLY FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED
BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION
OR REPAIR. This is an un-vented portable heater that uses air (Oxygen)
from within the area in which it is used. Failure to provide adequate
combustion and ventilation air will result in asphyxiation, carbon monoxide
poisoning, bodily injury or death. Refer to “Ventilation” on Page 6.
MODEL NUMBERS:
MH-80TBOA-OFR
Factory ID: 500
DANGER
DANGER
BATTERY OPERATED
KEROSENE RADIANT HEATER
User’s Manual & Operating Instructions
Sauk Rapids, MN 56379 USA • Toll Free (800) 641-6996
Fax: 320-251-2922 • Web: • Email: info@pinnacleclimate.comwww.masterindustrialproducts.com
Š 2023 Pinnacle Climate Technologies, Inc. MARE-409
Master is a registered trademark of Pinnacle Climate Technologies, Inc.
U.S. Patent No. 9,644,863
Locating Your Serial Number:
Your serial number can be found on a blue label on the left side cover. It will begin with the letter “S”
followed by 9 digits. For Example: S160901126. Have your Serial Number ready before calling customer
service at 800-641-6996.
2
© 2023 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in
any building which is used in whole or in part for human habitation. Use of this heating device
in Massachusetts requires local re department permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City Fire Code prohibits the storage, handling
and use of kerosene fueled heaters for space heating. Any person violating that provision
may be punished by a ne up to $10,000 and a term of imprisonment of up to 6 months.
Look for this icon throughout the manual for helpful tips on how to assemble, use and
clean your OFR heater.
THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE
AUTHORITIES HAVING JURISDICTION AND CSA STANDARD B139.
WARNING: This product can expose you to chemicals, including leadand lead
compounds, whichareknown to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED.
DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.
WARNING
WARNING
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep com-
bustibles such as; building materials, paper or cardboard a safe dis-
tance away from the heater as recommended by these instructions.
Never use the heater in spaces which contain products such as; gasoline, solvents, paint
thinners, dust particles, volatile or airborne combustibles or any unknown chemicals. This is
an un-vented portable heater. It uses air (Oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to “Ventilation” on page 8. Bulk fuel
storage should be a minimum of 25 feet from heater.
WARNING
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND
THOROUGHLY UNDERSTAND THESE SAFETY AND OPERATING
INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this heater can result in
death, serious bodily injury, property loss or damage from the hazards of re, soot production,
explosions, burns, asphyxiation or carbon monoxide poisoning. Only persons who can read
and understand these instructions should use or service this heater.
WARNING
SAFETY INFORMATION
Safety Information 2-3 ......................................................
Specications 4 .................................................................
Features 4 ...........................................................................
What’s in the Box 4 ...........................................................
Assembly 4-5 ......................................................................
Operation 6-7 .....................................................................
Battery Operation Instructions 8 ...................................
Maintenance 9-10 ..............................................................
Wiring Diagram 11 ..............................................................
Troubleshooting Guide 12 ...............................................
Exploded View 13 ..............................................................
Parts List 14 .........................................................................
Limited Warranty 15 ...........................................................
TABLE OF CONTENTS
3
© 2023 Pinnacle Climate Technologies, Inc. Kerosene Radiant Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and
extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzine, paint
thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the heater
is operating or still hot. This heater is EXTREMELY
HOT while in operation.
NEVER block air outlet (front).
NEVER use duct work in front of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
MH-80TBOA-OFR
Top 4 ft. (122 cm)
Sides 4 ft. (122 cm)
Front 8 ft. (244 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it
is plugged in, it can start at anytime in accordance
with the thermostat setting.
Extreme caution is necessary when any heater is
used by or near children or persons with reduced
physical, sensory or mental capabilities.
Do not add fuel when the heater is running. Heater
should be re-started after 24 hours of operation.
RISK OF ELECTRIC
SHOCK!
WARNING
RISK OF BURNS,
FIRE AND
EXPLOSION!
WARNING
CAUTION! HOT
WHILE IN OP-
ERATION. DO NOT
TOUCH. KEEP CHILDREN, ANIMALS, CLOTHING
AND COMBUSTIBLES AWAY FROM HEATER.
WARNING
The products described in this manual are
kerosene direct-red, forced air heaters. Kerosene
forced air heaters are primarily intended for use for
temporary heating of buildings under construction,
alteration or repair. Direct-red means that all
of the combustion products of the heater enter
the heated space. This appliance is rated at 98%
combustion eciency, but does produce small
amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation in
accordance with the instructions in this manual can
result in death.
People with breathing problems should consult
a physician before using this heater. Early signs
of carbon monoxide poisoning resemble the
flu. Symptoms of improper ventilation/carbon
monoxide poisoning are:
Headache • Dizziness • Nausea Dry Mouth •
Sore Throat • Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more aected by carbon monoxide
than others. These include: pregnant women, those
with heart or lung problems, anemia or those under
the influence of alcohol or at high altitudes.
NOT FOR USE WHERE EXPOSED TO THE
WEATHER, INDOOR USE PERMITTED ONLY FOR:
The temporary heating of adequately ventilated
buildings or structures under construction,
alteration or repair! Provide at least a three
square foot (2,800 sq cm) opening of outside
air for every 100,000 BTU/Hr (29 kW) heater
rating. Refer to “Ventilation” on page 6 for further
instructions.
RISK OF INDOOR
AIR POLLUTION!
WARNING
CARBON
MONOXIDE
POISONING MAY
LEAD TO DEATH!
DANGER
SAFETY INFORMATION CONT.


Produktspezifikationen

Marke: Master
Kategorie: Heizung
Modell: MH-80TBOA-OFR

Brauchst du Hilfe?

Wenn Sie Hilfe mit Master MH-80TBOA-OFR benĂśtigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Heizung Master

Bedienungsanleitung Heizung

Neueste Bedienungsanleitung fĂźr -Kategorien-