Model: GA7063 GA7063R GA9063 GA9063R
Wheel diameter 180mm 230mm
Max. wheel thickness 7.2mm 6.5mm
Spindle thread M14 or M16 or 5/8″ (country specic)
Rated speed (n) 8,500min-1 6,600min-1
Overall length 450mm
Net weight 5.6kg 5.8kg
Safety class /II
• Due to our continuing program of research and development, the specications herein are subject to change
without notice.
• Specications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
Read instruction manual.
Wear safety glasses.
DOUBLE INSULATION
Only for EU countries
Do not dispose of electric equipment
together with household waste material! In
observance of the European Directive, on
Waste Electric and Electronic Equipment
and its implementation in accordance with
national law, electric equipment that have
reached the end of their life must be col-
lected separately and returned to an envi-
ronmentally compatible recycling facility.
Intended use
The tool is intended for grinding, sanding and cutting of
metal and stone materials without the use of water.
Power supply
The tool should be connected only to a power supply of the same
voltage as indicated on the nameplate, and can only be operated
on single-phase AC supply. They are double-insulated and can,
therefore, also be used from sockets without earth wire.
For public low-voltage distribution
systems of between 220 V and 250 V
Only for model GA7063 / GA9063
Switching operations of electric apparatus cause voltage
uctuations. The operation of this device under unfavor-
able mains conditions can have adverse effects to the
operation of other equipment. With a mains impedance
equal or less than 0.25 Ohms it can be presumed that
there will be no negative effects. The mains socket used
for this device must be protected with a fuse or protective
circuit breaker having slow tripping characteristics.
Noise
The typical A-weighted noise level determined accord-
ing to EN60745:
Model GA7063
Sound pressure level (L
pA) : 91 dB(A)
Sound power level (L
WA) : 102 dB (A)
Uncertainty (K) : 3 dB(A)
Model GA7063R
Sound pressure level (L
pA) : 91 dB(A)
Sound power level (L
WA) : 102 dB (A)
Uncertainty (K) : 3 dB(A)
Model GA9063
Sound pressure level (L
pA) : 91 dB(A)
Sound power level (L
WA) : 102 dB (A)
Uncertainty (K) : 3dB(A)
Model GA9063R
Sound pressure level (L
pA) : 91 dB(A)
Sound power level (L
WA) : 102 dB (A)
Uncertainty (K) : 3dB(A)
WARNING: Wear ear protection.
Vibration
The vibration total value (tri-axial vector sum) deter-
mined according to EN60745:
Model GA7063
Work mode: surface grinding with normal side grip
Vibration emission (a
h, AG) : 7.0 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: surface grinding with anti vibration side grip
Vibration emission (a
h, AG) : 6.5 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: disc sanding with normal side grip
Vibration emission (a
h, DS) : 2.5 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: disc sanding with anti vibration side grip
Vibration emission (a
h, DS) : 2.5 m/s2 or less
Uncertainty (K) : 1.5 m/s2
Model GA7063R
Work mode: surface grinding with normal side grip
Vibration emission (a
h, AG) : 7.0 m/s2
Uncertainty (K) : 1.5 m/s2
3 ENGLISH
Work mode: surface grinding with anti vibration side grip
Vibration emission (a
h, AG) : 6.5 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: disc sanding with normal side grip
Vibration emission (a
h, DS) : 2.5 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: disc sanding with anti vibration side grip
Vibration emission (a
h, DS) : 2.5 m/s2 or less
Uncertainty (K) : 1.5 m/s2
Model GA9063
Work mode: surface grinding with normal side grip
Vibration emission (a
h, AG) : 6.5 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: surface grinding with anti vibration side grip
Vibration emission (a
h, AG) : 5.5 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: disc sanding with normal side grip
Vibration emission (a
h, DS) : 2.5 m/s2 or less
Uncertainty (K) : 1.5 m/s2
Work mode: disc sanding with anti vibration side grip
Vibration emission (a
h, DS) : 2.5 m/s2 or less
Uncertainty (K) : 1.5 m/s2
Model GA9063R
Work mode: surface grinding with normal side grip
Vibration emission (a
h, AG) : 6.5 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: surface grinding with anti vibration side grip
Vibration emission (a
h, AG) : 5.5 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode: disc sanding with normal side grip
Vibration emission (a
h, DS) : 2.5 m/s2 or less
Uncertainty (K) : 1.5 m/s2
Work mode: disc sanding with anti vibration side grip
Vibration emission (a
h, DS) : 2.5 m/s2 or less
Uncertainty (K) : 1.5 m/s2
NOTE: The declared vibration emission value has
been measured in accordance with the standard test
method and may be used for comparing one tool with
another.
NOTE: The declared vibration emission value
may also be used in a preliminary assessment of
exposure.
WARNING: The vibration emission during actual
use of the power tool can differ from the declared
emission value depending on the ways in which the
tool is used.
WARNING: Be sure to identify safety measures
to protect the operator that are based on an estima-
tion of exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it is
running idle in addition to the trigger time).
WARNING: The declared vibration emission
value is used for main applications of the power tool.
However if the power tool is used for other applica-
tions, the vibration emission value may be different.
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
SAFETY WARNINGS
General power tool safety warnings
WARNING: Read all safety warnings and
all instructions. Failure to follow the warnings and
instructions may result in electric shock, î‚¿re and/or
serious injury.
Save all warnings and instruc-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Work area safety
1. Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
2. Do not operate power tools in explosive atmo-
spheres, such as in the presence of ammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
3. Keep children and bystanders away while
operating a power tool. Distractions can cause
you to lose control.
Electrical Safety
1. Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodiî‚¿ed plugs and matching outlets will
reduce risk of electric shock.
2. Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of elec-
tric shock if your body is earthed or grounded.
3. Do not expose power tools to rain or wet con-
ditions. Water entering a power tool will increase
the risk of electric shock.
4. Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges
or moving parts. Damaged or entangled cords
increase the risk of electric shock.
5. When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk of
electric shock.
6. If operating a power tool in a damp location
is unavoidable, use a residual current device
(RCD) protected supply. Use of an RCD reduces
the risk of electric shock.
7. Use of power supply via an RCD with a rated
residual current of 30 mA or less is always
recommended.
Personal Safety
1. Stay alert, watch what you are doing and use
common sense when operating a power tool.
Do not use a power tool while you are tired or
under the inuence of drugs, alcohol or med-
ication. A moment of inattention while operating
power tools may result in serious personal injury.


Produktspezifikationen

Marke: Makita
Kategorie: Schleifer
Modell: GA7063RX02

Brauchst du Hilfe?

Wenn Sie Hilfe mit Makita GA7063RX02 benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Schleifer Makita

Bedienungsanleitung Schleifer

Neueste Bedienungsanleitung für -Kategorien-