INSTRUCTION MANUAL
Cordless Impact Wrench
DTWA070
DTWA100
DTWA140
DTWA190
ENGLISH: Original instructions
IMPORTANT: Read Before Using.
2 ENGLISH
SPECIFICATIONS
Model: DTWA070 DTWA100 DTWA140 DTWA190
Fastening capacities Standard bolt M5 - M12 M6 - M16 M8 - M16
High tensile bolt M5 - M10 M6 - M12 M8- M14
Maximum fastening torque 65 Nโ€ขm 95 Nโ€ขm 140 Nโ€ขm 185 Nโ€ขm
Torque range Approx.
5 - 40 Nโ€ขm
Approx.
6 - 65 Nโ€ขm
Approx.
18 - 80 Nโ€ขm
Approx.
25 - 125 Nโ€ขm
Square drive 9.5 mm 12.7 mm
No load speed (RPM) 0 - 2,500 min-1 0 - 2,700 min-1 0 - 2,600 min-1
Impacts per minute 0 - 3,700 min-1 0 - 3,300 min-1 0 - 3,000 min-1
Overall length 144 mm 151 mm 158 mm
Rated voltage D.C. 14.4 V
Net weight 1.1 - 1.4 kg 1.2 - 1.4 kg 1.2 - 1.5 kg 1.3 - 1.6 kg
โ€ข๎€ƒ Due๎€ƒto๎€ƒour๎€ƒcontinuing๎€ƒprogram๎€ƒof๎€ƒresearch๎€ƒand๎€ƒdevelopment,๎€ƒthe๎€ƒspeci๎‚ฟcations๎€ƒherein๎€ƒare๎€ƒsubject๎€ƒto๎€ƒchange๎€ƒ
without notice.
โ€ข๎€ƒ Speci๎‚ฟcations๎€ƒmay๎€ƒdiffer๎€ƒfrom๎€ƒcountry๎€ƒto๎€ƒcountry.
โ€ข๎€ƒ The๎€ƒweight๎€ƒmay๎€ƒdiffer๎€ƒdepending๎€ƒon๎€ƒthe๎€ƒattachment(s),๎€ƒincluding๎€ƒthe๎€ƒbattery๎€ƒcartridge.๎€ƒThe๎€ƒlightest๎€ƒand๎€ƒheavi-
est combination, according to EPTA-Procedure 01/2014, are shown in the table.
Applicable battery cartridge and charger
Battery๎€ƒcartridge BL1415N / BL1415NA / BL1430 / BL1430B / BL1440 / BL1450 /
BL1460A / BL1460B
Charger DC18RC / DC18RD / DC18RE / DC18SD / DC18SE / DC18SF /
DC18SH
โ€ข๎€ƒ Some๎€ƒof๎€ƒthe๎€ƒbattery๎€ƒcartridges๎€ƒand๎€ƒchargers๎€ƒlisted๎€ƒabove๎€ƒmay๎€ƒnot๎€ƒbe๎€ƒavailable๎€ƒdepending๎€ƒon๎€ƒyour๎€ƒregion๎€ƒof๎€ƒ
residence.
WARNING: Only use the battery cartridges and chargers listed above.๎€ƒUse๎€ƒof๎€ƒany๎€ƒother๎€ƒbattery๎€ƒcartridges๎€ƒ
and๎€ƒchargers๎€ƒmay๎€ƒcause๎€ƒinjury๎€ƒand/or๎€ƒ๎‚ฟre.
Symbols
The๎€ƒfollowings๎€ƒshow๎€ƒthe๎€ƒsymbols๎€ƒused๎€ƒfor๎€ƒthe๎€ƒequip-
ment.๎€ƒBe๎€ƒsure๎€ƒthat๎€ƒyou๎€ƒunderstand๎€ƒtheir๎€ƒmeaning๎€ƒbefore๎€ƒ
use.
Read instruction manual.
Ni-MH
Li-ion
Only๎€ƒfor๎€ƒEU๎€ƒcountries
Do not dispose of electric equipment or
battery๎€ƒpack๎€ƒtogether๎€ƒwith๎€ƒhousehold๎€ƒwaste๎€ƒ
material!
In observance of the European Directives,
on Waste Electric and Electronic
Equipment and Batteries and Accumulators
and Waste Batteries and Accumulators
and their implementation in accordance
with national laws, electric equipment and
batteries๎€ƒand๎€ƒbattery๎€ƒpack(s)๎€ƒthat๎€ƒhave๎€ƒ
reached the end of their life must be col-
lected๎€ƒseparately๎€ƒand๎€ƒreturned๎€ƒto๎€ƒan๎€ƒenvi-
ronmentally๎€ƒcompatible๎€ƒrecycling๎€ƒfacility.
Intended use
The tool is intended for fastening bolts and nuts.
Noise
The๎€ƒtypical๎€ƒA-weighted๎€ƒnoise๎€ƒlevel๎€ƒdetermined๎€ƒaccord-
ing to EN62841-2-2:
Model DTWA070
Sound pressure level (L
pA) : 92 dB(A)
Sound power level (L
WA) : 103 dB (A)
Uncertainty๎€ƒ(K)๎€ƒ:๎€ƒ3๎€ƒdB(A)
Model DTWA100
Sound pressure level (L
pA) : 93 dB(A)
Sound power level (L
WA) : 104 dB (A)
Uncertainty๎€ƒ(K)๎€ƒ:๎€ƒ3๎€ƒdB(A)
Model DTWA140
Sound pressure level (L
pA) : 96 dB(A)
Sound power level (L
WA) : 107 dB (A)
Uncertainty๎€ƒ(K)๎€ƒ:๎€ƒ3๎€ƒdB(A)
Model DTWA190
Sound pressure level (L
pA) : 95 dB(A)
Sound power level (L
WA) : 106 dB (A)
Uncertainty๎€ƒ(K)๎€ƒ:๎€ƒ3๎€ƒdB(A)
NOTE: The declared noise emission value(s) has
been measured in accordance with a standard test
method๎€ƒand๎€ƒmay๎€ƒbe๎€ƒused๎€ƒfor๎€ƒcomparing๎€ƒone๎€ƒtool๎€ƒwith๎€ƒ
another.
NOTE: The declared noise emission value(s)
may๎€ƒalso๎€ƒbe๎€ƒused๎€ƒin๎€ƒa๎€ƒpreliminary๎€ƒassessment๎€ƒof๎€ƒ
exposure.
3 ENGLISH
WARNING: Wear ear protection.
WARNING: The noise emission during actual
use of the power tool can differ from the declared
value(s) depending on the ways in which the
tool is used especially what kind of workpiece is
processed.
WARNING: Be sure to identify safety mea-
sures to protect the operator that are based on an
estimation of exposure in the actual conditions of
use (taking account of all parts of the operating
cycle such as the times when the tool is switched
off and when it is running idle in addition to the
trigger time).
Vibration
The vibration total value (tri-axial vector sum) deter-
mined according to EN62841-2-2:
Model DTWA070
Work mode: impact tightening of fasteners of the maxi-
mum๎€ƒcapacity๎€ƒof๎€ƒthe๎€ƒtool
Vibration emission (a
h) : 9.0 m/s2
Uncertainty๎€ƒ(K)๎€ƒ:๎€ƒ1.5๎€ƒm/s
2
Model DTWA100
Work mode: impact tightening of fasteners of the maxi-
mum๎€ƒcapacity๎€ƒof๎€ƒthe๎€ƒtool
Vibration emission (a
h) : 8.5 m/s2
Uncertainty๎€ƒ(K)๎€ƒ:๎€ƒ1.5๎€ƒm/s
2
Model DTWA140
Work mode: impact tightening of fasteners of the maxi-
mum๎€ƒcapacity๎€ƒof๎€ƒthe๎€ƒtool
Vibration emission (a
h) : 10.0 m/s2
Uncertainty๎€ƒ(K)๎€ƒ:๎€ƒ1.5๎€ƒm/s
2
Model DTWA190
Work mode: impact tightening of fasteners of the maxi-
mum๎€ƒcapacity๎€ƒof๎€ƒthe๎€ƒtool
Vibration emission (a
h) : 10.5 m/s2
Uncertainty๎€ƒ(K)๎€ƒ:๎€ƒ1.5๎€ƒm/s
2
NOTE: The declared vibration total value(s) has been
measured in accordance with a standard test method
and๎€ƒmay๎€ƒbe๎€ƒused๎€ƒfor๎€ƒcomparing๎€ƒone๎€ƒtool๎€ƒwith๎€ƒanother.
NOTE:๎€ƒThe๎€ƒdeclared๎€ƒvibration๎€ƒtotal๎€ƒvalue(s)๎€ƒmay๎€ƒalso๎€ƒ
be๎€ƒused๎€ƒin๎€ƒa๎€ƒpreliminary๎€ƒassessment๎€ƒof๎€ƒexposure.
WARNING: The vibration emission during
actual use of the power tool can differ from the
declared value(s) depending on the ways in which
the tool is used especially what kind of workpiece
is processed.
WARNING: Be sure to identify safety mea-
sures to protect the operator that are based on an
estimation of exposure in the actual conditions of
use (taking account of all parts of the operating
cycle such as the times when the tool is switched
off and when it is running idle in addition to the
trigger time).
EC Declaration of Conformity
For European countries only
The๎€ƒEC๎€ƒdeclaration๎€ƒof๎€ƒconformity๎€ƒis๎€ƒincluded๎€ƒas๎€ƒAnnex๎€ƒA๎€ƒ
to this instruction manual.
SAFETY WARNINGS
General power tool safety warnings
WARNING:
Read all safety warnings, instruc-
tions, illustrations and speci๎‚ฟcations provided with this
power tool. Failure to follow all instructions listed below
may๎€ƒresult๎€ƒin๎€ƒelectric๎€ƒshock,๎€ƒ๎‚ฟre๎€ƒand/or๎€ƒserious๎€ƒinjury.
Save all warnings and instruc-
tions for future reference.
The๎€ƒterm๎€ƒ"power๎€ƒtool"๎€ƒin๎€ƒthe๎€ƒwarnings๎€ƒrefers๎€ƒto๎€ƒyour๎€ƒ
mains-operated๎€ƒ(corded)๎€ƒpower๎€ƒtool๎€ƒor๎€ƒbattery-operated๎€ƒ
(cordless) power tool.
Work area safety
1. Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
2. Do not operate power tools in explosive atmo-
spheres, such as in the presence of ๎ƒ€ammable
liquids, gases or dust. Power tools create sparks
which๎€ƒmay๎€ƒignite๎€ƒthe๎€ƒdust๎€ƒor๎€ƒfumes.
3. Keep children and bystanders away while
operating a power tool. Distractions can cause
you๎€ƒto๎€ƒlose๎€ƒcontrol.
Electrical safety
1. Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power
tools. Unmodi๎‚ฟed๎€ƒplugs๎€ƒand๎€ƒmatching๎€ƒoutlets๎€ƒwill๎€ƒ
reduce risk of electric shock.
2. Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of elec-
tric๎€ƒshock๎€ƒif๎€ƒyour๎€ƒbody๎€ƒis๎€ƒearthed๎€ƒor๎€ƒgrounded.
3. Do not expose power tools to rain or wet con-
ditions. Water entering a power tool will increase
the risk of electric shock.
4. Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges
or moving parts. Damaged or entangled cords
increase the risk of electric shock.
5.
When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
6. If operating a power tool in a damp location
is unavoidable, use a residual current device
(RCD) protected supply. Use of an RCD reduces
the risk of electric shock.
7.
Power tools can produce electromagnetic ๎‚ฟelds
(EMF) that are not harmful to the user. However,
users of pacemakers and other similar medical
devices should contact the maker of their device and/
or doctor for advice before operating this power tool.
Personal safety
1. Stay alert, watch what you are doing and use
common sense when operating a power tool.
Do not use a power tool while you are tired or
under the in๎ƒ€uence of drugs, alcohol or med-
ication. A moment of inattention while operating
power๎€ƒtools๎€ƒmay๎€ƒresult๎€ƒin๎€ƒserious๎€ƒpersonal๎€ƒinjury.