UPS ONLINE SINGLE PHASE IN/OUT
1KVA / 900W
DATASHEET
MODEL: UPS-OLC10DP
| DATASHEET
Rack Tower design
High frequency and true double-conversion
DSP digital control technology
Input power factor correction (PFC)
Wide input voltage range (110V-300V)
Output power factor 0.9
Cold start
Frequency adaptive
ECO mode operation for energy saving
Selected output voltage via LCD
Output bypass settable for 1/2/4KVA via LCD
50Hz / 60Hz frequency converter mode avaiable on 6-10KVA
Selectable battery low voltage via LCD
Automatically diagnose when starts
Advanced batery management (ABM)
Short circuit and overload protection
Automatically charging battery at UPS off mode
Fan speed auto control when load varies
Standard RS232 communication port and RJ45 protection
FEATURES
EMERGENCY
POWER OFF
FAN INTELLIGENT
SLOT
USB OUTPUT
SOCKET
BATTERY
SLOT
INPUT POWER
TERMINALS
OVER CURRENT
PROTECTOR
SURGE PROTECTION FOR
NETWORK/FAX/MODEM
CONVERTIBLE
RACK / TOWER DESIGN
POWER
KEY
DISPLAY
LCD
SETTING
KEY
ENTER
KEY
SPECIFICATION
MODEL - CAPACITY
INPUT
Rated Voltage
Voltage Range
Frequency
Power Factor
Bypass Voltage Range
OUTPUT
Voltage
Voltage regulation
Frequency
Waveform
Crest factor
Harmonic distortion
Tranfer time
Overload capability
BATTERY
DC Voltage
Inbuilt battery
Charge current
Typical recharge time
ALARM
Utility failure
Battery low
Overload
UPS fault
EFFICIENCY
AC Mode
Battery mode
ECO mode
UPS-OLC10DP - 1KVA / 900W
208V / 220V / 230V / 240VAC
Half load (115-295) ± 5VAC, Full load (145-95) ± 5VAC
45-55Hz ± 0.5%Hz or 55-65Hz ± 0.5%Hz (Auto Sensing)
≥0.98
Rated output voltage -34V - Rated output voltage +32V
208V / 220V / 230V / 240VAC Setting available via LCD
± 1%
Synchronized with utility on AC mode; 50/60 ± 0.2Hz on battery mode
Pure sine wave
3:1
≤3% (linear load); ≤5% (Non-linear load)
AC mode to battery mode: 0ms / Inverter model to bypass mode 4ms(Typical)
105%-150%: Transfer to bypass after 30s / ›150: Transfer to bypass after 300ms
24V
2 x 9Ah
1A
8 Hours recover to 90% capacity
Beep / 4sec
Beep / 1sec
Beep twice / 1sec
Long Beep
≥90%
≥87%
≥98%
| DATASHEET


Produktspezifikationen

Marke: Mach Power
Kategorie: Nicht kategorisiert
Modell: UPS-OLC10DP

Brauchst du Hilfe?

Wenn Sie Hilfe mit Mach Power UPS-OLC10DP benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert Mach Power

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-