Technical manual
Mounting instructions
EM2010 DX
CHARACTERISTICS
The DirectXion lock can be mounted in all four mounting directions. Also, by flipping the lock,
all blocking directions can be achieved. The mounting dimensions are standard. The lock is
delivered with metric (M6) mounting screws. The PCB board in this lock is intended as an
OEM solution for customers who would like to control the lock via their own electronics. Once
voltage is supplied the lock will open for a 5 seconds and the boltwork can be moved into
OPEN position by pushing the bolt inside the lock case. After 5 seconds the board will cut
power to blocking element regardless if voltage is still supplied from external system. When
moving the boltwork into LOCKED position the DirectXion automatically locks. To open the
lock again the voltage has to be dropped and re-applied.
BOLTWORK REQUIREMENTS and MOUNTING INSTRUCTIONS
The maximum allowed cable/spindle-hole diameter is 12mm (if located under the lock body)
If the DirectXion lock is used in conjunction with another lock, the boltwork must be
constructed in a way that the DirectXion secures first.
In the LOCKED position the distance between the
DirectXion bolt and the boltwork part that is
moving the lock bolt should be approximately 1
mm.
Only use supplied screws to mount the lock.
Tighten the screws securely so the lock body is
attached firmly to the mounting surface.
DirectXion
M-LOCKS BV Tel: +31 (0)314 376 876
Vlijtstraat 40 ver. 1.2 2010 10 28 Fax: +31 (0)314 376 878
NL-7005 BN Doetinchem 2 of 2 www.m-locks.com
Connection to lock is via a RJ45 (female) connector on lock case. Cable (Art.nr. 390) has to
be ordered separately. Min voltage: 9V, Maximum voltage: 12V.
DirectXion
M-LOCKS BV Tel: +31 (0)314 376 876
Vlijtstraat 40 ver. 1.2 2010 10 28 Fax: +31 (0)314 376 878
NL-7005 BN Doetinchem 1 of 2 www.m-locks.com
Technical manual
Mounting instructions
EM3510 DX
CHARACTERISTICS
The DirectXion lock can be mounted in all four mounting directions. Also, by flipping the lock,
all blocking directions can be achieved. The mounting dimensions are standard. The lock is
delivered with metric (M6) mounting screws. The PCB board in this lock is intended as an
OEM solution for customers who would like to control the lock via their own electronics. Once
voltage is supplied the lock will open for a 5 seconds. The lock can be opened. After 5
seconds the board will cut power to blocking element regardless if voltage is still supplied
from external system. To open the lock again after closure the voltage has to be dropped and
re-applied.
BOLTWORK REQUIREMENTS and MOUNTING INSTRUCTIONS
The maximum allowed cable/spindle-hole diameter is 12mm (if located under the lock body)
If the DirectXion lock is used in conjunction with another lock, the boltwork must be
constructed in a way that the DirectXion secures first.
Only use supplied screws to mount the lock. Tighten the screws securely so the lock body is
attached firmly to the mounting surface.
Produktspezifikationen
Marke: | M-Locks |
Kategorie: | Gewölbe |
Modell: | EM2010 DX |
Brauchst du Hilfe?
Wenn Sie Hilfe mit M-Locks EM2010 DX benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten
Bedienungsanleitung Gewölbe M-Locks
27 August 2024
27 August 2024
27 August 2024
27 August 2024
27 August 2024
27 August 2024
27 August 2024
27 August 2024
27 August 2024
27 August 2024
Bedienungsanleitung Gewölbe
- Gewölbe Hama
- Gewölbe Philips
- Gewölbe Guzzanti
- Gewölbe Thule
- Gewölbe Conrad
- Gewölbe FERM
- Gewölbe Topcraft
- Gewölbe Dometic
- Gewölbe Abus
- Gewölbe Olympia
- Gewölbe Yale
- Gewölbe Perel
- Gewölbe Workzone
- Gewölbe Westfalia
- Gewölbe Burg Wächter
- Gewölbe Honeywell
- Gewölbe Filex
- Gewölbe First Alert
- Gewölbe Master Lock
- Gewölbe Phoenix
- Gewölbe Rottner
- Gewölbe Salvus
- Gewölbe SentrySafe
- Gewölbe Juwel
- Gewölbe Toolland
- Gewölbe Kidde
- Gewölbe Royal Sovereign
- Gewölbe SereneLife
- Gewölbe Sygonix
- Gewölbe Fluke
- Gewölbe VARO
- Gewölbe Duralock
- Gewölbe EasySafe
- Gewölbe Fichero
- Gewölbe FireKing
- Gewölbe Jewel
- Gewölbe Kreator-Varo
- Gewölbe Nauta
- Gewölbe Oxloc
- Gewölbe Protector
- Gewölbe ROMA
- Gewölbe Sentry
- Gewölbe Sistec
- Gewölbe SMC
- Gewölbe Steren
- Gewölbe Technomax
- Gewölbe Avanti
- Gewölbe Olymp
- Gewölbe Challenge
- Gewölbe Suncast
- Gewölbe Kreator
- Gewölbe Barska
- Gewölbe NOFIRE
- Gewölbe Homak Security
- Gewölbe CAWI
- Gewölbe Rottner Tresor
- Gewölbe Winholt
- Gewölbe Stamony
Neueste Bedienungsanleitung für -Kategorien-
16 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
5 Oktober 2024
5 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024