LiftMaster LMWEKITU Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für LiftMaster LMWEKITU (24 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 12 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/24
MONITORED
WIRELESSEDGEKIT
Models LMWEKITU and LMWETXU
To prevent possible SERIOUS INJURY or DEATH from a closing gate or door:
Be sure to DISCONNECT ALL POWER to the operator BEFORE installing the wireless
edgekit.
The gate or door MUST be in the fully opened or closed position BEFORE installing the
LiftMaster® Monitored Entrapment Protection device.
Correctly install and connect the wireless edge kit.
LiftMaster® Monitored Entrapment Protection devices are for use with LiftMaster
® UL 325
compliant Gate and Commercial Door Operators ONLY. Use with ANY other product voids
the warranty.
Monitored external entrapment protection devices MUST be installed per the operator
installation manual for each Entrapment Zone.
WARNING: This product can expose you to chemicals including lead, which are
known to the State of California to cause cancer or birth defects or other reproductive
harm. For more information go to www.P65Warnings.ca.gov.
INTRODUCTION
The LiftMaster Wireless Edge Kit provides a Bluetooth
® connection between a LiftMaster monitored
resistive edge (not included) and the gate operator. Maximum range is 130 ft. (39.6 m.) (for best
results install with a clear line of sight between transmitter and receiver, objects in the path may
reduce range). You can program up to 4 transmitters to the receiver. The kit works with LiftMaster
monitored resistive edge sensors ONLY. Contact closure edge sensors are NOT supported.
Refer to your gate operator manual to ensure compatibility (LMWEKITU and LMWETXU is listed
under Monitored Entrapment Protection devices of the section). Transmitter and Accessories
receiver are UL Recognized Components and meet UL 325 requirements. A monitored entrapment
protection device MUST be installed in each entrapment zone.
Compatible LiftMaster® Gate Operators:
CSW24U/UL HDSL24UL LA412U/UL HDSW24UL
RSW12U/UL CSL24U/UL LA500U/UL IHSL24UL
SL585U/UL RSL12U/UL CSW200U/UL INSL24UL
LA400U/UL SL5959U/UL SL300U/UL
Illustrations in manual are for reference only, your application may look different.
CARTON INVENTORY
Transmitter Model LMWETXU Receiver
10-16 x 3/4" Screw (4)
I2C Interface Board
4-40 x 1/4" Screw (2)
6-32 x 1" Screw (for metal)
6-19 x 1" Screw (for plastic)
Spacer
Mounting Bracket (2)
Wire Clip
Cable ties (3)
8-32 x 3/8" Screw (2)
or
AA Lithium Batteries (2)
Energizer
® Ultimate Lithium AA L91
REQUIRED as replacements
Double hole Heyco connectorSingle hole Heyco connector
WIRE THE RECEIVER
IMPORTANT: Disconnect ALL power to the operator.
1. Find your operator diagram on pages 5-7 to see the mounting location for
the receiver and wire routing.
2. Open the receiver housing.
3. Route the wire harness from the receiver to the operator. Connect the wire harness
to one of the following locations depending on your operator and application:
The EXP. BOARD or EXPANSION terminal on the control board.
The WIRELESS EDGE terminal on the expansion board (if installed).
One of the data bus terminals on the relay adapter board: Models HDSL24UL,
and HDSW24UL ONLY.
The I2C interface board: Required ONLY when using an expansion board with
a single terminal labeled TO MAIN BOARD. Install and connect as
shownbelow (if installed).
4. Tighten the Heyco connector with 25 in. lbs. of torque to make receiver watertight.
5. Reconnect power to the operator. The receiver blue power LED will come on.
Expansion Board
TO MAIN BOARD terminal
Expansion Board
(if applicable)
Relay Adapter Board
(if applicable)
6-19 x 1"
(for plastic)
6-32 x 1"
(for metal)
Control Board
Tighten Heyco nut
to 25 in. lbs. torque
Receiver
OR
OR OR
To Control Board
To Receiver
I2C Interface Board
(if applicable)
OR
1
2
2INSTALL TRANSMITTER BATTERIES AND SET
EDGE DIRECTION
1. Open the transmitter housing.
2. Install the batteries. DO NOT let the bottom housing hang by the wires. Energizer
®
Ultimate Lithium AA L91 batteries are REQUIRED as replacements.
3. Decide the direction (open or closed) the edge will be installed. Set OPEN/CLOSE
DIP switch to match the direction of the edge protection.
OPEN/CLOSE DIP Switches
PROGRAMMING
The receiver can learn up to 4 transmitters.
1. Press the learn button on the RECEIVER board. The red LED will come on to
indicate programming mode. NOTE: To exit programming mode, press the learn
button again.
2. Press the learn button on the TRANSMITTER to be learned. The red LED on the
RECEIVER will blink 4 times. If adding an additional TRANSMITTER, press it’s learn
button. NOTE: Learn mode times out after 60 seconds if no transmitters are added
or the capacity is reached. After each transmitter is learned there will be an
additional 60 seconds to complete programming.
3
Learn Button
MOUNT THE RECEIVER
IMPORTANT: Disconnect ALL power to the operator.
1. Find the operator diagram on pages 5-7 to see the mounting location for the
receiver.
2. Attach the mounting bracket to the gate operator with the screws provided
(8-323/8" or 10-16 3/4").
3. Attach the receiver housing with screws provided.
4. Place the receiver onto the mounting bracket and secure with the 1/4" screw
provided.
5. Reconnect power to the operator.
4
2 3 4
OR
WIRE AND MOUNT THE TRANSMITTER(S)
For best results, install with a clear line of sight between transmitter and operator. The
transmitter can be wired to 1 or 2 edge sensors.
1. Route the wires from the edge sensor into the transmitter. Connect the wires to either
terminal block (polarity is NOT important). The operator will beep once to indicate the
edge sensor has been learned. Apply pressure to edge. The red LED will flash if the
transmitter is wired correctly. Tighten the Heyco connector with 25 in. lbs. of torque
to make transmitter watertight. Use double hole Heyco connector when connecting 2
edge sensors.
2. Attach the mounting bracket to the gate with the screws provided (8-32 3/8" or 10-16
3/4") at least 3.28 ft. (1 m) above the ground. If installing on a round surface, use zip
ties (not provided).
3. Attach the transmitter housing with the screws provided.
4. Place the transmitter onto the mounting bracket and secure with the
1/4"screwprovided.
5
1
2 3
4
≥ 3.28'
(1 m)
OR
Tighten Heyco nut to 25 in. lbs. torque
TEST
Apply pressure to edge. The red LED on the TRANSMITTER and the corresponding
open or close edge LED on the gate operator control board will flash. If the
TRANSMITTER LED does not flash, check the transmitter for proper installation and
wiring, see page 4 and check the edge Transmitter and Receiver Troubleshooting
sensor for proper installation and wiring, see page 4. Edge Sensor Troubleshooting
6
Status LED
3
TROUBLESHOOTING
The diagnostic display on the gate operator control board shows a code to indicate a problem.
View Diagnostic Codes
1. Press and hold the STOP button.
2. Press and hold the CLOSE button.
3. Press and hold the OPEN button until “Er” shows on the display.
The operator will show the code sequence number followed by the code number. The operator will
save the 20 most recent codes. Use the OPEN and CLOSE buttons to scroll through the saved
codes.
Diagnostic mode will time out after 2 minutes of inactivity or press and release the STOP button to
exit diagnostic mode.
Diagnostic Codes for LMWEKITU
46 Wireless edge battery low Replace batteries in wireless edge.
67 Wireless edge triggered
more than 3 minutes
Check wired input for wiring issue or obstruction.
68 Wireless Edge triggered Normal response when an edge makes contact with an
object. See page 4.Edge Sensor Troubleshooting
69 Wireless Edge loss of
monitoring
See troubleshooting steps below, paying attention to
intermittent wire connections.
84
Non-monitored device
detected on the wireless
safety system
Ensure that the installed edge is a LiftMaster product.
Install a LiftMaster monitored edge sensor.
DUAL GATE SETUP
For dual gate applications, one receiver (with corresponding transmitter) is REQUIRED for each
gate operator.
Secondary OperatorPrimary Operator
ReceiverReceiver
Transmitter Transmitter
BATTERY STATUS
When the edge is activated, the red status LEDs on the transmitter(s) and receiver flash to indicate
the battery status.
NOTE: The receiver LED corresponds to the lowest battery level of all transmitters.
1 Flash Battery is fine.
2 Flashes Battery is low; the operator will beep twice.
3 Flashes Battery is critically low; the operator will not function until the battery is
replaced. The operator will either open automatically (fail-safe) or latch
at close (fail-secure) based on the operator setting (see the gate
operator manual for more information).
Transmitter
Status LED
Receiver
Status LED
REMOVE A TRANSMITTER
1. Disconnect the edge sensor wires from the TRANSMITTER.
2. Remove the batteries from the TRANSMITTER.
3. Press and hold the RECEIVER learn button until the red status LED begins to flash (about 3
seconds) then release. The receiver will return to normal operation after 60 seconds. Any
transmitters that have been removed will automatically be erased from memory.
1-2 3
Receiver
Transmitter
Learn Button
ERASE ALL TRANSMITTERS FROM MEMORY
Press and hold the RECEIVER learn button until the red status LED begins to flash. Press and hold
the receiver learn button until after the learn button stops flashing. The gate operator will beep for 5
seconds to confirm all transmitters are erased.
DIAGNOSTICS
Control Board


Produktspezifikationen

Marke: LiftMaster
Kategorie: Nicht kategorisiert
Modell: LMWEKITU

Brauchst du Hilfe?

Wenn Sie Hilfe mit LiftMaster LMWEKITU benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert LiftMaster

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-