LiftMaster HDSW24UL Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für LiftMaster HDSW24UL (64 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 10 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/64
COMMERCIAL DC
VEHICULAR SWING GATE OPERATOR
INSTALLATION MANUAL
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
• THIS PRODUCT MUST BE INSTALLED AND
SERVICED IN ACCORDANCE WITH THIS
MANUAL BY A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
• This model is for use on vehicular passage
gates ONLY and not intended for use on
pedestrian passage gates.
• This model is intended for use in Class I, II,
III and IV vehicular swing gate applications.
• Visit LiftMaster.com to locate a professional
installing dealer in your area.
• This gate operator is compatible with myQ®
and Security+ 2.0® accessories.
Access installation and technical support
guides or register this product
Send it in by texting
the photo to 71403.
Take a photo of the
camera icon including
the points ( ).
1.
2.
HDSW24ULTECH
Model HDSW24UL
2
SAFETY 2
Safety Symbol and Signal Word Review ................................................2
Usage Class ...........................................................................................3
UL325 Entrapment Protection Requirements ........................................3
Safety Installation Information ...............................................................4
Role of Dealers, Installers, and Trained Gate System Technicians ........5
Role of End Users/Home Owners ..........................................................5
Gate Construction Information ...............................................................6
INTRODUCTION 7
Carton Inventory ....................................................................................7
Operator Specifications ..........................................................................8
Site Preparation .....................................................................................9
Check Your Gate ....................................................................................9
INSTALLATION 10
Types of Installations ...........................................................................10
Step 1 Determine Location for Concrete Pad and Operator .................11
Step 2 Concrete Pad and Operator Attachment ...................................13
Step 3 Position the Gate Bracket .........................................................14
Step 4 Adjust the Operator Arm Length ...............................................14
Step 5 Secure the Operator Arm ..........................................................15
Step 6 Install Entrapment Protection ...................................................16
Step 7 Earth Ground Rod .....................................................................18
Step 8 Power Wiring ............................................................................18
Step 9 Connect Batteries .....................................................................20
Step 10 Dual Gate Setup ......................................................................22
Step 11 Install the Cover .....................................................................24
ADJUSTMENT 25
Limit, Speed, and Force Adjustment ....................................................25
Obstruction Test ..................................................................................27
PROGRAMMING 28
Remote Controls (not provided) ..........................................................28
LiftMaster Internet Gateway (not provided) .........................................29
CAPXL Connected Access Portal .........................................................29
Erase All Codes ....................................................................................30
Erase Limits .........................................................................................30
Constant Pressure Override (CPO) ......................................................30
Gate Hold Open Feature .......................................................................30
To Remove and Erase Monitored Entrapment Protection Devices .......30
OPERATION 31
Gate Operator Setup Examples ............................................................31
Control Board Overview .......................................................................32
Manual Disconnect ..............................................................................33
Reset Switch ........................................................................................33
Relay Board and Terminal Block Access ..............................................33
Operator Alarm ....................................................................................34
Remote Control ....................................................................................34
ACCESSORY WIRING 35
External Control Devices ......................................................................35
Locks ...................................................................................................36
Miscellaneous Wiring ...........................................................................36
EXPANSION AND RELAY BOARDS 37
Expansion and Relay Boards Overview ................................................37
Auxiliary Relays ...................................................................................38
Wiring Accessories to the Expansion Board ........................................39
MAINTENANCE 40
Important Safety Instructions ..............................................................40
Maintenance Chart ...............................................................................41
Batteries ...............................................................................................41
TROUBLESHOOTING 42
Diagnostic Codes .................................................................................42
Control Board LEDs .............................................................................43
Troubleshooting Chart .........................................................................44
SOLAR PANELS 47
Step 8 Solar Panel(s) ...........................................................................47
REPAIR PARTS 51
ACCESSORIES 52
WARRANTY 54
APPENDIX 55
SAMS Wiring with Relays Not Energized .............................................55
Dual Gate Settings ...............................................................................56
Limit Setup with a Remote Control ......................................................57
Wiring Diagram ....................................................................................58
Diagnostic Codes Table .......................................................................59
Site Planning Safety Checklist .............................................................61
CONTACT INFORMATION 64
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
When you see these Safety Symbols and Signal Words on the following pages, they will alert
you to the possibility of if you do not comply with the warnings that Serious Injury or Death
accompany them. The hazard may come from something mechanical or from electric shock.
Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility of
damage to your gate and/or the gate operator if you do not comply with the cautionary
statements that accompany it. Read them carefully.
IMPORTANT NOTE:
• BEFORE attempting to install, operate or maintain the operator, you must read and fully
understand this manual and follow all safety instructions.
• DO NOT attempt repair or service of your gate operator unless you are a Trained Gate
Systems Technician.
MECHANICAL
ELECTRICAL
TABLE OF CONTENTS
SAFETY
Safety Symbol and Signal Word Review
3
Usage Class
Class I - Residential Vehicular Gate Operator
A vehicular gate operator (or system) intended for use in garages or parking areas
associated with a residence of one-to four single families.
Class II - Commercial/General Access Vehicular Gate
A vehicular gate operator (or system) intended for use in a commercial location or
building such as a multi-family housing unit (five or more single family units), hotel,
garages, retail store, or other buildings accessible by or servicing the general public.
Class III - Industrial/Limited Access Vehicular Gate
A vehicular gate operator (or system) intended for use in an industrial location or
building such as a factory or loading dock area or other locations not accessible by or
intended to service the general public.
Class IV - Restricted Access Vehicular Gate Operator
A vehicular gate operator (or system) intended for use in a guarded industrial location
or building such as an airport security area or other restricted access locations not
servicing the general public, in which unauthorized access is prevented via supervision
by security personnel.
UL325 Entrapment Protection Requirements
Definitions
ENTRAPMENT: The condition when a person is caught or held in a
position that increases the risk of injury.
SWING GATE ENTRAPMENT ZONE: Locations between a moving gate or
moving, exposed operator components and a counter opposing edge or
surface where entrapment is possible up to 1.8 m (6 ft.) above grade.
Such locations occur if during any point in travel:
a. The gap between the bottom of a moving gate and the ground is
greater than 101.6 mm (4") and less than 406 mm (16"); or
b. The distance between the center line of the pivot and the end of the
wall, pillar, or column to which it is mounted when in the open or
closed position exceeds 101.6 mm (4"). Any other gap between a
moving gate and fixed counter opposing edges or surfaces or other
fixed objects is less than 406 mm (16") (examples are walls, curbs,
berms or other immovable objects).
INDEPENDENT MONITORED ENTRAPMENT PROTECTION DEVICE: An
entrapment protection device is independent if it is a different type
(photoelectric sensors, edge device, inherent protection device) from the
other devices in the same entrapment zone.
Use the Site Planning Safety Checklist in the appendix to identify
entrapment zones found in your installation.
Requirements
•Aminimum of two independent monitored entrapment protection
devices are required to be installed at each entrapment zone.
• It is the responsibility of the installer to install external monitored
entrapment protection devices for each entrapment zone.
•The operator will only operate with a minimum of two independent
monitored entrapment protection devices installed in either the open
or closed direction. If no entrapment zone exists in the other
direction, an external entrapment protection device is NOT required in
that direction.
This operator has an inherent entrapment protection device built-in.
The installer MUST provide one additional entrapment protection
device for each entrapment zone.
Acceptable entrapment protection device types include:
• Inherent (built into the operator)
• LiftMaster monitored external photoelectric sensors, see page 52 for
acceptable sensors.
• LiftMaster monitored external edge sensors, see page 52 for
acceptable sensors.
IMPORTANT SAFETY
INSTRUCTIONS
To reduce the risk of INJURY or DEATH:
• READ AND FOLLOW ALL INSTRUCTIONS.
• NEVER let children operate or play with gate controls. Keep the
remote control away from children.
• ALWAYS keep people and objects away from the gate. NO ONE
SHOULD CROSS THE PATH OF THE MOVING GATE.
• Test the gate operator monthly. The gate MUST reverse on
contact with an object or reverse when an object activates the
noncontact sensors. After adjusting the speed, force, or the limit
of travel, retest the gate operator. Failure to adjust and retest the
gate operator properly can increase the risk of INJURY or DEATH.
• Use the manual release ONLY when the gate is not moving.
• KEEP GATES PROPERLY MAINTAINED. Read this manual. Have a
Trained Gate Systems Technician make repairs to gate hardware.
• The entrance is for vehicles ONLY. Pedestrians MUST use separate
entrance.
•SAVE THESE INSTRUCTIONS.


Produktspezifikationen

Marke: LiftMaster
Kategorie: Nicht kategorisiert
Modell: HDSW24UL

Brauchst du Hilfe?

Wenn Sie Hilfe mit LiftMaster HDSW24UL benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert LiftMaster

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-