LiftMaster CAPXL Bedienungsanleitung


Lesen Sie kostenlos die 📖 deutsche Bedienungsanleitung für LiftMaster CAPXL (8 Seiten) in der Kategorie Nicht kategorisiert. Dieser Bedienungsanleitung war für 41 Personen hilfreich und wurde von 2 Benutzern mit durchschnittlich 4.5 Sternen bewertet

Seite 1/8
1
LiftMaster Smart Access Systems
Installation Readiness Survey
Name:
Address:
City/State/ZIP:
Mobile/Cell#:
Email:
Satisfactory
Needs Action
Required Connectivity
I. INTERNET SPECIFICATIONS
Component: Result
(Circle) Verified: Action Needed Date
Completed
1. I have a dedicated line for each device at
this facility. Yes / No If , call your Internet Service No
Provider (ISP) to add one.
2. The Internet Service Provider (ISP) is:
3. Router’s make/model/manufacture date:
4. Modem/gateways make/model/
manufacture date:
5. The dedicated bandwidth is at least 5 Mbps
for each Smart Video Intercom unit (except
CAPAC and CAP2D). (TIP: Use a known
internet speed tester for measuring.)
Yes / No Upload => 5 Mbps
Download => 5 Mbps
If , check for other network devic-No
es sharing bandwith. Call your ISP to
match need.
6. Other equipment on site (example: cameras,
WI-FI repeater, radio tower): Yes / No If , list them in the Yes
On-site Equipment List section.
Assess current internet connection details of the community site prior to new unit or upgrade of an installation, and identify action items needed to proceed. Perform this
assessment separately for each connected access device. IMPORTANT: Fill out the form COMPLETELY. Incomplete or missing information identifies action items to be
completed before installation can begin.
Before you begin...
Gather necessary IT information and staff to assess site readiness. Survey completion can serve as a quick reference site inventory.
RECOMMENDED TOOLS
Computer running Microsoft Windows (unlock with Ethernet port)
Internet Speed Tester
LAN/WAN Network Checker
Wi-Fi analyzer
Ethernet Cable (5-10’)
Ethernet Cable RJ45 Coupler (Female-Female)
WilsonPro 460118 RF Cellular Signal Meter
Speedcheck App (app store)
Netanalyzer (app store)
SURVEY PERFORMED BY:
SITE CONTACT
First Name:
Last Name:
Job Title:
Email:
Mobile/Cell#:
SITE INFORMATION
Site/Facility Name: Survey Date:
myQ Community Account: Proposed Install Date:
Street Address:
City/State/Zip:
Site Information
TECH SUPPORT CONTACT
First Name:
Last Name:
Job Title:
Email:
Mobile/Cell#:
Satisfactory
2
2. CONNECTION METHOD (CHOOSE ONE)
Component: Result
(Circle) Verified: Action Needed Date
Completed
OPTION 1: WIRED (Select one type):
DSL
Cable
Fiber ISP
OPTION 2: WIRELESS (Wi-Fi™ )
Wi-Fi network name:
Wi-Fi password:
The dBm Signal Strength is between -30 dBm
and -67 dBm. (TIP: USE a Wi-Fi Analyzer tool to
measure this. See Fig. 2.)
Yes / No If , you need to adjust the distance No
from the router to the control.
3. SIP PROVIDER
Component: Result
(Circle) Verified: Action Needed Date
Completed
A SIP account is required for calling function.
LiftMaster only supports Phone.com for video
calling features and cannot guarantee or
support 3rd party SIP provider’s compatibility for
voice only calling.
Yes / No
If , see step 6 and establish Phone.No
com service in the app’s Device
Management tab.
4. INTERNET PROTOCOL
Component: Verified √: Action Needed Date
Completed
Internet Protocol (Select one type):
Dynamic Host Configuration Protocol (DHCP). Any device can connect.
Static IP (Assigned to be recognized with specific parameters listed below.)
If , provide the additional Static IP
specifications below.
FOR STATIC IP
IP Address:
Netmask:
Gateway Address:
Primary Domain Name Service (DNS):
Secondary DNS:
Tertiary DNS :
3
6. ACCOUNT SETUP myQ COMMUNITY
Action: Verified √: Action Needed Date
Completed
1a. For existing accounts, create a myQ Community.
1b. Call LiftMaster Tech Support - Access Control at 877-247-6764 to
set up a myQ Community account.
2. Respond within 24 hours to the email invitation to register.
3. Proceed within your account to complete:
FACILITY (your site profile - ALL REQUIRED FIELDS)
PEOPLE (including residents and credentials)
5. PHYSICAL CABLING SPECIFICATIONS
Component: Result
(Circle) Verified: Action Needed Date
Completed
Existing cabling is CAT 6 or greater for new
installations. (CAT 5e is adequate for existing
installations.)
Yes / No
If , recabling using CAT 6 or No
greater is required. Consult with your
service provider to replace the cable.
The cabling from router to connected access
installation point is less than 300' cabling
length.
Yes / No
If , you need to adjust and shorten No
the distance between the internet
router and the unit.
Patch Cable follows configuration (for router
or switch) in Fig. 1 on the next page. Yes / No
The outlet for the CAPX-system MUST be an external dedicated 120 Vac outlet. Refer
to the table below for maximum wire run distances. This outlet should be wired back to
its own 10 Amp minimum circuit breaker.
NOTE: Main power supply and control wiring MUST be run in separate
conduits. Conduits must be UL approved for low and high voltage. Refer to the
NEC for additional wiring requirements.
IMPORTANT: An earth ground rod is strongly recommended and should be no further than 12 feet (3.7 m) from the CAPX-system and use a
minimum of 12 gauge wire in most cases. The type and length of earth ground rods vary by region. Contact the AHJ (Authority Having Jurisdiction) in
the municipality where you plan to install the CAPX-system for correct grounding materials and installation procedures. A proper ground is critical to
minimizing risk for the CAPX-system from damaging electrical transients.
WIRE SPECIFICATION MAXIMUM RUN DISTANCE
14 AWG Up to 300 feet (91.4 m)
16 AWG Up to 200 feet (60.9 m)
18 AWG Up to 100 feet (30.4 m)


Produktspezifikationen

Marke: LiftMaster
Kategorie: Nicht kategorisiert
Modell: CAPXL

Brauchst du Hilfe?

Wenn Sie Hilfe mit LiftMaster CAPXL benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert LiftMaster

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-