1
LIGHT
HOLD
OPEN
To prevent possible SERIOUS INJURY or DEATH from electrocution:
Be sure power is NOT connected BEFORE installing door control.
Connect ONLY to 12 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
Install door control within sight of garage door, out of reach of children at a minimum
height of 5 feet (1.5 m), and away from ALL moving parts of door.
NEVER permit children to operate or play with door control push buttons or remote control
transmitters.
Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no
obstructions to door travel.
ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross
path of closing garage door.
PREMIUM MOTION-DETECTING CONTROL PANEL
Models 881LM and 886LM
Feature Overview
TIMER-TO-CLOSE (TTC) FOR MODEL 881LM ONLY
DO NOT enable TTC if operating a one-piece door. TTC is to be used ONLY with sectional doors.
The TTC can be set to automatically close your garage door after a specified period of time (1, 5,
or 10 minute intervals). The garage door opener will beep and the lights will ash before closing
the door. If the door encounters an obstruction while closing, the garage door opener will make a
second attempt to close the door. If the obstruction has not been cleared after the second attempt,
the garage door opener will reverse open, stop and WILL NOT close until the obstruction has been
cleared. TTC WILL NOT work if the garage door opener is operating by battery power or if the
safety reversing sensors are misaligned. This feature is NOT intended to be the primary method of
closing the door. A keyless entry should be installed in the event of an accidental lock out when
using this feature.
Premium Motion-Detecting
Control Panel
Safety Reversing
Sensors
Yellow
LEARN Button
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifi cations of this receiver and/or transmitter are
prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards for Home or offi ce use. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
For use with Security 2.0TM Garage Door Openers. All Security 2.0TM Garage Door Openers have
a yellow Learn button and two yellow antennas. The features are adjustable and may be turned off
or on as desired. Refer to the Feature Settings section.
MOTION SENSOR
The motion sensor will automatically turn on the garage door opener lights when motion is
detected. The lights will come on for the set period of time, then shut off. The factory setting is on
and set at 4-1/2 minutes.
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the garage door opener system stays in good
working condition. The MAS feature MUST be activated at time of installation. The factory setting
is off. The service LED will come on after 4500 garage door opener cycles. This indicates the
garage door opener may need maintenance; contact your installation dealer. If the MAS feature is
activated, the command LED (yellow) and the service LED (red) will alternate flashing back and
forth.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned
on they will stay on until the LIGHT button is pressed again, or until the garage door opener is
activated. Once the garage door opener is activated the lights will turn off after the specified period
of time (the factory setting is 4-1/2 minutes). The LIGHT button will not control the lights when the
door is in motion.
LOCK
The LOCK feature is designed to prevent activation of the garage door opener from remote controls
while still allowing activation from the door control and keyless entry. This feature is useful for
added peace of mind when the home is empty (i.e. vacation).
2
RED
WHITE
WHITE
GREY
TE
Installation
Install the door control within sight of the door at a minimum height of 5 feet (1.5 m) where small
children cannot reach, and away from the moving parts of the door. For gang box installations it is
not necessary to drill holes or install the drywall anchors. Use the existing holes in the gang box.
NOTE: Pre-wiring means that your garage already has wires installed for the door control.
WIRE THE DOOR CONTROL
1
2
3
1
2
3
4
5
6
1
2
3
7/16" (11 mm)
7/16" (11 mm)
Unplug the garage door opener to
ensure the door control cannot be
activated during wiring.
Strip 7/16" (11 mm) of insulation from
one end of the wire and separate the
wires.
Connect the wire to both screws on the
back of the door control. The wires can
be connected to either screw.
PRE-WIRED INSTALLATIONS: Choose any two
wires to connect, but make note of which wires
are used.
MOUNT THE DOOR CONTROL
Mark the location of the bottom
mounting hole and drill a 5/32" (4 mm)
hole.
Install the bottom screw, allowing
1/8" (3 mm) to protrude from the wall
Position the bottom hole of the door
control over the screw and slide down
into place.
Lift the push bar up and mark the top
hole.
Remove the door control from the wall
and drill a 5/32" (4 mm) hole for the
top screw.
Position the bottom hole of the door
control over the screw and slide down
into place. Attach the top screw.
WIRE TO GARAGE DOOR OPENER
Strip 7/16" (11 mm) of insulation from
the end of the wire near the garage door
opener.
Connect the wire to the red and white
terminals on the garage door opener.
The wires can be connected to either
terminal.
Reconnect power to the garage door
opener. The command LED behind the
push bar on the door control will blink
if installed correctly. To synchronize
the garage door opener and the door
control, press the push bar up to
3 times. Press until the garage door
opener activates.
PRE-WIRED INSTALLATIONS: Connect the same
wires to the garage door opener that were
previously connected to the door control.
To insert or release wire, push
in tab with screwdriver tip.
GANG BOXDRYWALL
6ABx1-1/4" Drywall Anchors 6-32x1"
HARDWARE
1
2
3
4
5
6
- Wall -
3
TO ADD, REPROGRAM, OR CHANGE A REMOTE CONTROL/KEYLESS ENTRY PIN
Program
Operation
PUSH BAR
Press the push bar to open/close the door.
GARAGE DOOR OPENER LIGHTS
Press the LIGHT button to turn the garage door
opener lights on or off. When the lights are
turned on they will stay on until the LIGHT
button is pressed again, or until the garage
door opener is activated. Once the garage door
opener is activated the lights will turn off after
the specified period of time (the factory setting
is 4-1/2 minutes). The LIGHT button will not
control the lights when the door is in motion.
Press the LEARN button on the door
control to enter Programming Mode.
Press the LEARN button again, the
LED will flash once.
Press the button on the remote
control that you wish to operate
your garage door.
Enter a 4-digit personal
identification number (PIN) of your
choice on the keyless entry keypad.
Then press the ENTER button.
The garage door opener lights will flash (or two clicks will be heard) when the code has been programmed.
Repeat the steps above for programming additional remote controls or keyless entry devices.
The command LED will flash once. The command LED will flash once again.
PIN
? ? ? ?
12
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PRS
8
TUV
9
WXY
0
QZ
*
#
ENTER
0 QZ #
ENTER
LIGHT Button
OR
HOLD OPEN Button for the
Timer-To-Close (TTC)
Motion Sensor
1 2 3a 3b
Push Bar
1 Minute
TTC LED
5 Minute
TTC LED
10 Minute
TTC LED
MOTION SENSOR
This feature will automatically turn on the
garage door opener lights when motion is
sensed. The lights will come on for the set
period of time, then shut off.
LIGHT FEATURE
The lights will turn on when someone enters
through the open garage door and the safety
reversing sensor infrared beam is broken.
If using the garage door opener light as a work
light, turn the light on using the light button on
the wall control or the light will turn off if you
are beyond the range of the sensor.
TIMER-TO-CLOSE (TTC) 881LM ONLY
DO NOT enable TTC if operating a one-piece
door. TTC is to be used ONLY with sectional
doors.
The TTC can be turned on or off and the time
interval can be adjusted to 1, 5, and 10 minute
intervals. Once the TTC has been set and the
door is open, the selected close interval will
blink and begin to count down to close the
door. The garage door opener will beep and the
lights will flash before closing the door.
To temporarily suspend the TTC feature press
and release the HOLD OPEN button (the HOLD
OPEN button will light solid). Press the HOLD
OPEN button again to resume normal TTC
operation.
The TTC feature will deactivate if the garage
door encounters an obstruction twice; or the
safety reversing sensors are incorrectly
installed. The garage door will reverse open and
WILL NOT close until the obstructions are clear
or the safety reversing sensors are correctly
installed. When the obstruction has been
cleared or the safety reversing sensors have
been aligned, the door will close when the
garage door opener is activated.


Produktspezifikationen

Marke: LiftMaster
Kategorie: Nicht kategorisiert
Modell: 881LM

Brauchst du Hilfe?

Wenn Sie Hilfe mit LiftMaster 881LM benötigen, stellen Sie unten eine Frage und andere Benutzer werden Ihnen antworten




Bedienungsanleitung Nicht kategorisiert LiftMaster

Bedienungsanleitung Nicht kategorisiert

Neueste Bedienungsanleitung für -Kategorien-